The flow velocity sensor heats up to approximately 150C. Fluid velocity detection element GD 347 LLB Series Specific Product Precautions 3 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 6 to 8 for Air Preparation Equipment Precautions.
, 600 80 Symbol Specifications/Descriptions 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 XA 100 Change of rod end shape 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Oversized rod cylinder XB5 125 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (150C
(Max. 150C) Heat resistant Sensor section: Rail Amplifier section: DIN rail Grommet D-F7NJL 7-9-35 Wide range detection type Wide range detection D-G5NBL Band Grommet This auto switch can be mounted by tie-rod with using mounting bracket. For details, refer to page 7-9-46.
Standard cylinder seals are replaced with special ones and other modifications are made in order to enable the cylinder to operate at a high ambient temperature (10 to 150C). Possible applications: Bore size 32 and 40 mm Rubber bumper Without magnets (Auto switches cannot be used at high temperature.)
Full stroke Clamp stroke Made to Order Heat resistant Max. 150C Refer to to p.5.4-1 regarding detailed specifications. 4.1-1 Series MK/MK2 Precautions Precautions Be sure to read before handling. Refer to p.0-39 to 0-46 for Safety Instructions and actuator and auto switch precautions.
3.50 4.11 4.88 2.59 3.08 No10-32UNF 0.31 16 (5/8) 0.60 0.71 0.71 0.79 0.79 .187 0.49 0.39 .188 1.08 0.20 0.10 0.31 H O W T O O R D E R SERIES NCJ2 HIGH TEMPERATURE RESISTANT CYLINDER XB6 OPTION T E C H N I C A L SPECIFICATIONS XB6 NCJ2 Applicable Cylinder Bore Size 6, 10, 16 Action Double Acting (Single/Double Rod) Single Rod W Double Rod S T R O K E Ambient and Fluid Temperature -10C~+150C
V V V V V V 25A Copper (Cu) and Zinc (Zn)-free Note 1) 32 to 100 V v v v v v v v MBlR V Water resistant V v V v V v V v 10Clean series Note 6) v v v v v v v v 32 to 125 20Copper Note 5) and Fluorine-free Note 6) Note 9) Note 9) Note 9) Note 9) Note 9) Note 9) Note 9) Note 9) XAl Change of rod end shape XB5 Oversized rod cylinder Note 6) v v v v v v v XB6 Heat resistant cylinder (10 to 150C
The temperature range for the protective label cover is between 40 to 110C, and the temperature range for grease is between 20 to 150C. (However, there is no relationship with the chemicals listed above.) 28 Series CJ5-S/CG5-S Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
The flow velocity sensor is heated to approximately 150C. 4. In cases where there is a danger of drainage or foreign matter being mixed in the fluid, install a filter or mist separator on the upstream side. Otherwise, the rectifying device built into the switch will become clogged and accurate measurement will not be possible. [When used for water] 5.
Accessories -XB6 Heat resistant cylinder (-10 to 150C) w/o auto switch only Note 1) MK-A012Z MK-A016Z MK-A020Z 12 16 20 25 32 40 50 63 Clamp bolt, Hexagon socket head cap screw, Hexagon nut, Spring washer -XC22 Fluororubber seals Note 2) Note 1) Except 12 and 16. Note 2) The bumper is a standard product.
size (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) 0.7 0.5 0.3 19.8 14.2 8.49 28.3 OUT 6 3 14.8 10.6 6.36 21.2 IN 55.0 39.3 23.6 78.5 OUT 10 4 46.2 33.0 19.8 66.0 IN Made to Order Specifications (For details, refer to pages 1395 to 1498.) 141 101 60.3 201 OUT 16 6 121 86.0 51.6 172 IN Symbol Specifications 220 157 94.2 314 OUT 20 8 Heat resistant (10 to 150C
Standard cylinder seals are replaced with special ones and other modifications are made in order to enable the cylinder to operate at a high ambient temperature (10 to 150C). CJ1 Possible applications: Bore size 8 to 20 mm Rubber bumper Without magnets (Auto switches cannot be used at high temperature.)
The temperature range for the protective label cover is between 40 to 110C, and the temperature range for grease is between 20 to 150C. (However, there is no relationship with the chemicals listed above.) 28 Series CJ5-S/CG5-S Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
A full range of order made specifications -XA0 to XA30 -XB5 -XB6 -XB13 -XC3 -XC4 -XC5 -XC6 -XC7 -XC8 -XC9 -XC10 -XC11 -XC12 -XC18 -XC22 -XC30 -XC35 -X846 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Modification of rod end shape Heavy duty rod Heat resistant cylinder (to 150C) Low speed cylinder Special port locations With heavy duty scraper Heat resistant cylinder (to 110C) Stainless
Specifications Applicable series CY3B Bore size 6 to 63 50 to 150C Ambient and fluid temperature Max. operating pressure 0.5 MPa 50 to 400 mm/s Piston speed When using in less than 100C range, since it could make a difference in the maintenance cycle, depending on the operating speed, use it at 200 mm/s or less.
MGP Series (Basic Type), Stroke Variations Stroke [mm] Bore size [mm] Bearing type Made to Order 10 20 25 30 40 50 75 100 125 150 175 200 250 300 350 400 12 -XA: Change of guide rod end shape -XB6: Heat resistant cylinder (10 to 150C) -XB10: Intermediate stroke (Using exclusive body) -XB13: Low speed cylinder (5 to 50 mm/s) -XC6: Made of stainless steel -XC8: Adjustable stroke cylinder/ Adjustable
Symbol Heat Resistant Cylinder (10 to 150C) -XB6 The seal material and grease for air cylinders have been changed for high temperature tolerance, now with a range of 10 to 150C.
Air-hydro type 20 to 63 V V 10-, 11Clean series 20 to 100 V V V V v Note 1) Note 1) 25ANote 9) Copper (Cu) and Zinc (Zn)-free Note 15) 20 to 100 V V v v v v v v 20Note 9) Copper Note 8) and Fluorine-free 20 to 100 V V V V v V v V CG1lR V Water resistant 32 to 100 V V V V v CG1lM Cylinder with stable lubrication function (Lube-retainer) 20 to 100 V v v v v XB6 Heat resistant cylinder (10 to 150C
Standard cylinder seals are replaced with special ones and other modifications are made in order to enable the cylinder to operate at a high ambient temperature (10 to 150C). CJ1 Possible applications: Bore size 8 to 20 mm Rubber bumper Without magnets (Auto switches cannot be used at high temperature.)
Symbol Specifications -XA Change of rod end shape -XB6 Heat resistant cylinder (150C) -XB7 Cold resistant cylinder -XB9 Low speed cylinder (10 to 50 mm/s) -XB10 Intermediate stroke (Using exclusive body) -XB13 Low speed cylinder (5 to 50 mm/s) -XB18 Low friction cylinder -XC6 Piston rod and rod end nut made of stainless steel -XC8 Adjustable stroke cylinder/Adjustable extension type -XC9