SMC Corporation of America
Elite Part Number Search
Search Results "LEY25EB-400W"

without brake 400W with brake 400W without brake 400W with brake Symbol A B C D G H J K Motor specifications Mitsubisi Electric Corporation, Yaskawa Electric Corporation, OMRON Corporation Standard strokes are available in 50 mm increments.

Do not mount the product where it is exposed to materials such as Cooling capacity Option silicone, which may generate harmful gas. 002 200W Nil None Install the product in a location where the ambient temperature range is E With foot, 004 400W no rack bracket between 10 to 35C and the relative humidity range is between 35 to 80%.

Heat generation amount Q: 400W (at 77F (25C)) Cooling capacity = Considering a safety factor of 20%, select 400W x 1.2 = 480 W (at 77F (25C)) or more. Example 2:When the heat generation amount in the customers machine is not known.

PD07PD09 (DO) ON/OFF 4.5.1(1)(d) JOGDO TM 4.5 MR Configurator2 No.PC09 MR Configurator2 11.8 TM master-slave masterslave C1 5.4.3 1 5 1 1.5 (1) LECS S 1 S5 50W,100W SSCNET S ACS5, S6 S5 ACS7 S7 200W ACS8 S8 400W AC100VAC120V 50Hz60Hz 1 AC200VAC230V 50Hz60Hz 2 1 6 1 (2) aSSCNET 5 A S LE C S M A AC S B M B E 2m 2 5m 5 10m A S R bSSCNET LE-CSS-MR-J3BUSM 1 LE C S S

Slider type LEFB series 3.1 Specification LEFB25,32,40 AC servo motor (100W / 200W/400W/) Model LEFB25 LEFB32 LEFB40 300,400,500,600,700, 800,900,1000,(1100), 300,400,500,600,700, 800,900,1000,(1100), 300,400,500,600,700, 800,900,1000,(1100), 1200,(1300,1400),1500, (1600,1700,1800,1900), 1200,(1300,1400),1500, (1600,1700,1800,1900), 1200,(1300,1400),1500, (1600,1700,1800,1900), Stroke [mm

Positioning repeatability [mm] 0.01 Lost motion[mm] Note3) 0.05 Lead [mm] 20 12 6 24 16 8 30 20 10 Impact/Vibration resistance [m/s2] Note4) 50/20 Actuation type Ball screw (LEKFS)Ball screw + Belt (LEKFSR/L) Guide type Linear guide Operating temperature [] 5 to 40 Operating humidity [%RH] 90 or less(No condensation) Motor output [W]/size [mm] 100W/40 200W/60 400W/60 specification Motor type

/www.smcpneumatics.ca (800) SMC.SMC1 (762-7621) e-mail: sales@smcusa.com For International inquires: www.smcworld.com 2012 SMC Corporation All Rights Reserved 11-E597 QT -RRD-5M Information AC Servo Motor Driver Series LECSm Power Supply Voltage 100 to 120 VAC 200 to 230 VAC Motor Capacity 100/200/400W Series LECSA (Pulse Input Type/Positioning Type) Incremental Type Absolute Type Up to 7

20 40 16 Lead 6: LEY25EB Lead 12: LEY25EA 30 8 10 20 Lead 12: LEY25EA 10 0 300 200 400 100 500 600 0 0 300 200 400 100 500 600 0 Speed [mm/s] Speed [mm/s] LEY32mE LEY32mE for acceleration/deceleration: 2000 mm/s2 90 50 Lead 4: LEY32EC Lead 4: LEY32EC 80 40 43 Horizontal work load [kg] Vertical work load [kg] 70 Lead 8: LEY32EB 60 30 40 45 50 Lead 8: LEY32EB Lead 16: LEY32EA 20 22 30 Lead

262144pulse/rev 5.8 9.6 9.4 9.2 9.5 MR Configurator MR Configurator MR Configurator MR Configurator 1 PB24 , PA06PA07 8.2 S PC13 13.2 5kW 13.3 5kW 13.4 PC18 1 8 1 PD06PD08 PD12PD14 () ON(RYn0)CN6 4.6.3 6.1.11 (DO) ON/OFF 7.7.4 JOGDO1 MR Configurator 7.7 (LSP)(LSN) 6.3.6 1 9 1 1.4 (1) LECS C 1 S5 C CC-Link ACS5, S6 50W,100W S5 ACS7 S7 200W ACS8 S8 400W

The cooling reduces about 400W from the value in the catalog. Cooling capacity W *1 Reqired minimum flow rate for cooling capacity or maintaining the temperature stability. *2 The capacity at the thermo-chiller outlet when the circulating fluid temperature is 20.

Heat generation amount: 400W Cooling capacity = Considering a safety factor of 20%, 400 x 1.2 = 480W 132 Model Selection Series HEC Guide to Model Selection Example 2 When the heat generation amount in the customers machine is not known. Obtain the temperature difference between inlet and outlet by circulating the fluid inside the customers machine.

For driver of 200W to 400W, regenerative resistor is not used. 02:LEC-MR-RB-032 03:LEC-MR-RB-12 Selection of regenerative option 00: Regenerative option is not used For servo amplifier of 100W, regenerative resistor is not used. For servo amplifier of 200 to 400W, built-in regenerative resistor is used. 02: MR-RB032 03: MR-RB12 4 6 4.

INSTALLATION POINT Close mounting is available for the driver of under 3.5kW for 200V class and 400W for 100V class. Leave a large clearance between the top of the driver and the internal surface of the control box, and install a cooling fan to prevent the internal temperature of the control box from exceeding the environmental conditions.

Approx.600W(water), 400W(Fluorinert FC-77) Cooling capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 8 L/min Approx.900W(water), 600W(Fluorinert FC-77) Heating capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 8 L/min Recirculating fluid : Water, Fluorine solvent(GALDEN HT-135

Driver type Driver select Motor select SMC Sigma Win+ SMC Sigma Win+ V5 SGDV-R90*11*Y572AA V6 SGMJV-01A3A2* 100W 200W V7 SGDV-1R6*11*Y572AA V7 SGMJV-02A3A2* LECYM2-** MECHATROLINK 400W V8 SGDV-2R8*11*Y572AA V8 SGMJV-04A3A2* V5 SGDV-R90*21*Y572AA V6 SGMJV-01A3A2* 100W MECHATROLINK 200W V7 SGDV-1R6*21*Y572AA V7 SGMJV-02A3A2* LECYU2-** 400W V8 SGDV-2R8*21*Y572AA V8 SGMJV-04A3A2* Trademarks

Driver type Driver select Motor select SMC Sigma Win+ SMC Sigma Win+ V5 SGDV-R90*11*Y572AA V6 SGMJV-01A3A2* 100W 200W V7 SGDV-1R6*11*Y572AA V7 SGMJV-02A3A2* LECYM2-** MECHATROLINK 400W V8 SGDV-2R8*11*Y572AA V8 SGMJV-04A3A2* V5 SGDV-R90*21*Y572AA V6 SGMJV-01A3A2* 100W MECHATROLINK 200W V7 SGDV-1R6*21*Y572AA V7 SGMJV-02A3A2* LECYU2-** 400W V8 SGDV-2R8*21*Y572AA V8 SGMJV-04A3A2* Trademarks

Driver Type Motor type Encoder Type Capacity C CC-Link type Absolute encoder S5 100W AC Servo motorS6*1 Absolute S7 200W AC Servo motorS7*1 S8 400W AC Servo motorS8*1 *1 This is a symbol of motor type (actuator part).

INSTALLATION (b) Installation of two or more drivers POINT Close mounting is available for the driver of under 3.5kW for 200V class and 400W for 100V class. Leave a large clearance between the top of the driver and the internal surface of the control box, and install a cooling fan to prevent the internal temperature of the control box from exceeding the environmental conditions.

Driver Type Motor type Encoder Type Capacity C CC-Link type Absolute encoder T5 100W AC Servo motorT6*1 T7 200W AC Servo motorT7*1 Absolute T8 400W AC Servo motorT8*1 T9 AC Servo motorT9*1 750W Power supply *1 This is a symbol of motor type (actuator part).