Number of Ports: 2 Port, Piping Direct., Plunger Length: 1 (Side Ported, Short), Body Option: Side Mounting, Port Size: N01 (NPT 1/8, Side Ported Only), Actuator Type: 02 (One Way Roller Lever), Suffix: None, Indicator: None

Number of Ports: 3 Port, Piping Direct., Plunger Length: 0 (Side Ported, Long), Body Option: U (w/Bottom Mounting Thread), Port Size: N01 (NPT 1/8, Side Ported Only), Actuator Type: 00 (Basic), Suffix: None, Indicator: None

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A2 (Bracket B, Horizontal Mounting)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A2 (Bracket B, Horizontal Mounting)

Pad Diameter: 50 (Flat+Flat with Ribs+Bellows+Compact+Compact with Ribs), Pad Styles: B (Bellows), Material: F (Fluoro Rubber), Rotating or Non-rotating: J (Rotating), Stroke: 50mm, Vacuum Entry: N01 (NPT 1/8), Mounting Thread: A14 (M14X1)

Pad Diameter: 50 (Flat+Flat with Ribs+Bellows+Compact+Compact with Ribs), Pad Styles: B (Bellows), Material: U (Urethane Rubber), Rotating or Non-rotating: J (Rotating), Stroke: 20mm, Vacuum Entry: N01 (NPT 1/8), Mounting Thread: A14 (M14X1)

Pad Diameter: ΓΈ40, Pad Type: HB (Heavy-duty, Bellows), Pad Material: S (Silicone Rubber), Buffer Body Material: JB (Brass + w/Bushing), Buffer Stroke: 25, Vacuum Inlet Thread Size: N01 (NPT1/8), Mounting Thread Size: A18 (M18 x 1.5)