M9BA, Lead wire(m): 3, Number Of Switches: 2, Port types: Rc 1/8
M9BA, Lead wire(m): 0.5 (M8 4-pin plug connector), Number Of Switches: 2, Port types: Rc 1/8
: M9BA, Lead wire(m): 0.5 (M8 4-pin plug connector), Number Of Switches: 2, Port types: Rc 1/8
M9BA, Lead wire(m): 0.5 (M8 4-pin plug connector), Number Of Switches: 2, Port types: Rc 1/8
: M9BA, Lead wire(m): 3, Number Of Switches: 2, Port types: Rc 1/8
: M9BA, Lead wire(m): 5, Number Of Switches: 2, Port types: Rc 1/8
M9BA, Lead wire(m): 3, Number Of Switches: 2, Port types: Rc 1/8
: M9BA, Lead wire(m): 0.5 (M8 4-pin plug connector), Number Of Switches: 2, Port types: Rc 1/8
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): Less than 1 / 1 to Less than 3 / 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 30, Valves: Provided, Allowable
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 50, Valves
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 50, Valves
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 50,
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20 / 20 to Less than 50, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 63, Valves:
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 6 to Less than 10 / 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 80,
Oscillation Angle A: 100°, Torque (Range)(N⋅m): 6 to Less than 10 / 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 80, Valves
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 6 to Less than 10 / 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 80, Valves
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves: Provided
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 1 to Less than 3 / 3 to Less than 6 / 6 to Less than 10 / 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 50, Valves