Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
Model Description AMR3000 AMR4000 AMR5000 AMR6000 : E4-02 : E4-03 : E4-04 1 4 3 8 1 2 1 4 1 2 : E6-06 : E6-10 3 4 1 : E3-02 : E3-03 : E5-04 : E5-06 Adapter assembly (6) 3 8 3 4 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float style auto drain (Bowl assembly) IS1000-01 (Set at 0.4MPa) Compact pressure switch PT elbow (7) 135510 135613 Note 5) in the gauge part number (e.g.
AS2001F-04-3-X12 Ex.) AS2001F-04-3-X21 Note) Not particle-free Throttle Valve (Without Check Valve) X214 Ex.)
BS5-180, BS5-200 D-Z7, Z8 D-Y5, Y6, Y7 3 Set screw M4 x 0.7 x 8L 2 D-A9 D-M9 BA-01, BA-02, BA-32, BA-04 BA-05, BA-06, BA-08, BA-10 BA2-020, BA2-025 BA2-032, BA2-040 BA5-050, BHN2-025, BSG1-032 BH2-040, BH2-050 BH2-080, BH2-100 BAF-32, BAF-04, BAF-05 BAF-06, BAF-08, BAF-10 BBA3 4 Auto switch mounting screw M4 x 0.7 x 22L 1 D-B5, B6 D-G5, K5 Besides the models listed in How to Order, the following
VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T Base size A, B Port size 5 3 4 6 1 Symbol 04 Port size VVPA450 VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.
20 40 11 21 0.5~4 L/min 2~16 L/min 5~40 L/min 10~100 L/min 50~250 L/min 2 04 20 40 11 21 R 04 20 40 11 21 S 250L/min G L/min(gal/min) / : SI : G : 1[L/min]=0.2642[gal/min] 1[gal/min]=3.785[L/min] 1=9/5+32 L/min 100L/min250L/min Rc N NPT F G IS0228 1 N M8(3m) 04 20 40 11 21 03 3/8 04 1/2 06 3/4 10 1/1 12 11/4 14 11/2 / OUT1 OUT2 1 1~5 V 2 4~20 mA 1T 1~5 V 1~5 V (PF3W3)1~5V (-1-1T
Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
Communication example When reading the product number and serial number Unit identifier 1 Function code 04 Read 19 consecutive data from register 005h.
FGDTF*-04 FGD-CV005-06 FGDTF*-06 (5) FGD-CV006-03 FGDCE*-03 FGD-CV006-04 FGDCE*-04 FGD-CV006-06 FGDCE*-06 FGD-OP001 FGD*B (10) KT-FGDC FGDC KT-FGDE FGDE (2)(4)(6)(13)(16) KT-FGDT FGDT KT-FGDF FGDF FGD-CA002 FGDT,F(L250) (7)(9)(11)(12)(13) (14)(15)(16)(17) FGD-CA003 FGDT,F(L500) L500 (18) FGD-CA004 FGDC,E(L250) FGD-CA005 FGDC,E(L500) 7/11 FGX-OM-L007-C 2. 2.
FGD-KT002 FGDE Nut kit FGD-KT003 FGDT FGD-KT004 FGDF FGD-CV005-03 FGDT,F-03 FGD-CV005-04 FGDT,F-04 FGD-CV005-06 FGDT,F-06 Replacement cover (5) FGD-CV006-03 FGDC,E-03 FGD-CV006-04 FGDC,E-04 FGD-CV006-06 FGDC,E-06 Joint FGD-OP001 FGDB (10) KT-FGDC FGDC Each of (2)(4)(6)(13) and (16) are provided as a kit.
M Weight (g) AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 Model Applicable tubing O.D. d 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 27.9 28.2 29.6 32.4 40.2 32.5 33.1
Description ARJM104, 6, 10 Manifold base How to Order ARJ1020F-M5-06 ARJ1020F-M5-04 M5 ARJ 20 10 F 04 1 Option Miniature regulator 1 Set at 0.2MPa Port size Only the adjusting spring is different from standard.
IDG60S to IDG100S IDG3 to IDG50 IDG3H to IDG50H IDG30L/ IDG50L Port size With separator regulator Symbol Bore Size 3 5 10 20 30 50 60 75 100 V IDG60 to IDG100 IDG60H to IDG100H IDG60L to IDG100L 01 1/8 02 1/4 IDG60S to IDG100S Note) Note) 03 3/8 04 1/2 Note 1) Specifications with element service indicator are also available. See the order made section on page 33.
VS3145-04 VS3145-06 VFN 1 4, 3 8, 1 2 64 64 65 70 1 136 35 9 64 54 19 32 50 50 118 96 120 60 7 1 2, 3 4 82 68 88 92 1 181 53 12 81 70 35 36 66 52 133 96 140 66 9 DC C Model VS3135-02 VS3135-03 VS3135-04 VS3145-04 VS3145-06 A B Port size Rc 1 4, 3 8, 1 2 64 50.8 163 196 68 60.5 1 2, 3 4 4-16-7
04 0 5 VK Thread type Series VP 5 port solenoid valve Manifold Nil Rc VZ G F N NPT Base size NPTF T VF Common EXH 5 6 3 4 A/B Port size 1 VFR Symbol Port size 04 06 10 M Note) 1 Mixed VVP460 VVP450 1 2 3 4 VP4 Porting specifications Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
N01 Connection NPT 1/8 N02 Connection NPT 1/4 Port size N03 Connection NPT 3/8 Option specifications Application Size Symbol N04 Connection NPT 1/2 IRV3000 IRV2000 IRV1000 F01 Connection G 1/8 01 02 03 04 1/8 1/4 3/8 1/2 F02 Connection G 1/4 F03 Connection G 3/8 F04 Connection G 1/2 Accessory (Option) Part No. Part no.
How to Order With bracket (standard) Air suction filter In-line type with One-touch fitting 100 04 B ZFC IN/OUT applicable tube O.D.
Flow direction 2(A) Flow direction 4(B) Flow direction 2(A) Flow direction 4(B) 90 45 45 Rc3/4: 185(10.2) 1 2 9.7 VH6 VH600-06, 10 3 (Closed center) 3/4, 1 Rc1: 194(10.5) 3 4 3.6-6 Series VH How to Order VH 2 0 1 02 1(P) port location Hand valve R Standard (Opposite to handle side) Handle side Body size (Base size) Port size (nominal size) 2 3 4 6 1/4 base 3/8 base 1/2 base 1 base 02 03 04
How to Order 100 04 B ZFC With bracket (Standard) Air suction filter in-line type with One-touch fittings IN/OUT applicable tubing O.D.
O-ring O,O Non plug-in type @ o End plate (kit) assy MEF363LR-04-t End plates O Joint/clamp O,O . Gasket O,O . O-ring O,O Plug-in type MEF373LH-04-1 End plates O . Joint/clamp O,O . casket O,O .