Auto switch a b d c Proper mounting positions (mm) A B Bore size (mm) 63 80 100 10 13 17.5 14 18.5 23.5 Proper mounting positions (mm) a b 14 18 17 c 20 24 23 d D-A9 type D-F9 type D-F9 W type 2 6 5 8 12 11 In order that adjacent switches do not misoperate, they should be set within 1mm of the proper mounting positions indicated in the table above.
Besides, do not connect a PLC, which can detect 1 [mA], since there is a leak current of 1 [mA] in OFF state. 0 Time Hi 5 to 40 [mA] B 10 [ms] or shorter B 10[ms] or shorter Brown OUT(+) Main circuit of switch Main circuit of switch Load A 5 [ms] or longer 12 to 24 [VDC] When the auto shift input is 10 [ms] or shorter, switch output responds.
Auto switch groove positions (mm) B 6.9 8.8 13.7 17.1 A 10 14 19 26 Bore size (mm) 6 10 16 20 4-4.2 Auto switch mounting groove B A 38
Reed Auto Switch: D-A9 (mm) Stroke B A Stroke C Stroke Model 5 10 15 20 5 5 10 10 15 15 20 20 MXJ4 MXJ6 MXJ8 9 4 14 0.5 14 0.5 3 9 4 14 0.5 14 0.5 18 -0.5 10 5 25 0.5 9 4 14 -0.5 14 -0.5 25 0.5 Solid State Auto Switch, 2-Color Indication Solid State Auto Switch: D-M9, D-M9W (mm) Stroke B A Stroke C Stroke Model 20 15 10 5 20 15 10 5 15 20 10 5 MXJ4 MXJ6 MXJ8 4.5 4.5 18 18 8 13 7 3.5
(Becomes close to the trapezoidal acceleration as the setting value reaches 0) Acceleration and deceleration ratio 10 10 10 to 100 EQY251 to 50 EQY321 to 70 Torque when held *2 50 70 Sets the torque when stopped after the positioning operation. (Unit: %) H 150 100 Sets the position loop P constant.
(C) 50 55 60 65 70 80 15 15 15 15 15 15 10 10 10 10 10 10 5 5 5 5 5 5 1.64 1.37 1.30 1.23 1.16 1.09 1.26 1.05 1.00 0.95 0.89 0.84 0.88 0.74 0.70 0.66 0.62 0.59 30 1.56 1.30 1.24 1.17 1.11 1.04 1.20 1.00 0.95 0.90 0.85 0.80 0.84 0.70 0.67 0.63 0.60 0.56 32 1.50 1.25 1.19 1.12 1.06 1.00 1.15 0.96 0.91 0.86 0.82 0.77 0.81 0.67 0.64 0.60 0.57 0.54 35 1.40 1.17 1.11 1.05 0.99 0.94 1.08 0.90 0.86
Auto switch groove position (mm) B 6.9 8.8 13.7 17.1 A 10 14 19 26 Bore size (mm) 6 10 16 20 4 x 4.2 Auto switch mounting groove B A 30 Series MXH Specific Product Precautions 1 Be sure to read before handling. Refer to front matters 42 and 43 for Safety Instructions and pages 3 to 11 for Actuator and Auto Switch Precautions.
of needle revolutions 5 10 Number of needle revolutions 10 20 0 Number of needle revolutions 5 10 10 Speed Controller for Low Speed Operation Series AS-FM Construction Parts list No. 1 2 3 4 5 6 7 8 9 10 11 Note Description Material Body A PBT Handle Black PBT Note 1) Body B Brass Electroless nickel plated Needle Brass Electroless nickel plated Needle guide Brass Electroless nickel plated
at front side QB 2-Plug WB GB E W (Diagonal I) (mm) I B GB P QA CD QB CT CZ D E FT FX FZ GA H Stroke A L Bore (mm) N O 1 8 1 4 1 4 50 14 depth 5 85 93 16 10 20 7 8 36 32 64 20 73 93 16 128 30 221 45 9 63 18 depth 6 103 107 24 12.5 20 8.5 10 45 40 77 25 90 114 24 144.5 30 251.5 54 11 80 20 depth 6 132 128 35 12.5 25 10 10 45 50 98 25 110 138 24 171.5 40 299.5 56 13 SRSH Bore size A, #1 (
Dimensions SFD100 different diameters SFD200 different diameters One-touch fitting dimensions(A, B) One-touch fitting dimensions(A, B) Port size q Port size w Port size q Port size w 4 8 4.5 5.5 SMC 6 10 Basic dimension 114.5 Basic dimension 72 5.5 4.5 Fitting dimension A Fitting dimension B Fitting dimension A Fitting dimension B 8 12 5.5 5 Total length 81 (A + 72 + B) 76.5 (72 + A) 81.5
M6 x 1 Depth 7.5 39 50 0 77 74 59 155 128 143 3/4, 1 74 46 06 10 06 10 90 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 107 06 10 94 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 111 5 Soft Start-up Valve AV2000/3000/4000/5000 Modular F.R.L.
Gasket DXT192-10-5 (Use caution to the orientation.) 3-3-30 5 Port Solenoid Valve Base Mounted Series VZ3000 Flow Characteristics/Weight Flow characteristics (1) Port size Valve model Type of actuation Weight (g) 1 4/2 (P A /B) 4, 2 (A, B) 1, 5, 3 (P , EA, EB) 4/2 5/3 (A/B EA/EB) b C [dm3/(sbar)] Cv C [dm3/(sbar)] Cv b Grommet 125 (75) 170 (120) Single Double Closed center Exhaust center
G Description 04 06 10 02 03 04 02 03 04 VY110 0 1VY120 0 1VY130 0 1VY140 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 VY1D00-M5 VY1A0 0 1-M5 VY150 0 1VY1B0 0 1M 0 5 1 01 02 01 02 PPA B VEX9-32A VEX5-32A VEX7-32A VEX3-32A VEXA-18-2A VEX1-18-1A Bracket (With bolt, washer) AL F VEX1-18-2A VEXA-18-3A G27-10-R1-X207 G G46-10-01 G36-10-01 G27-10-01 Pressure gauge AN120-M5 AN120-M5 Pilot EXH port silencer
e Order No. b d f l1 c a 32 M10x1.25 GKM10-20 10 40 10 52 20 20 40 M12x1.25 GKM12-24 12 48 12 62 24 24 50/63 M16x1.5 GKM16-32 16 64 16 83 32 32 80/100 M20x1.5 GKM20-40 20 80 20 105 40 40 Rod end nut (standard equipment) 30 d D C H B Bore size (mm) Order No.
Standard M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 10-V14: 13(27) 10-V14A: 16(30) 10-V14: 12(26) 10-V14A: 15(29) Large flow capacity Standard 10-V124A Note 1) Large flow capacity Valve model 12 [32 Note 3)] Flow characteristics 23 [21 Note 3)] b b Cv Cv C[dm3/(sbar)] 0.054 0.099 0.037 0.076 C[dm3/(sbar)] 0.037 0.076 0.054 0.099 10-V114 10-V114A 10-V124 Note 1) 0.008 0.016 0.015 0.024 0.015 0.024
Replacement Actuator (Cylinder) CY1F R B 10 Stroke Cylinder identification symbol Piping direction suffix R L Centralized piping on right Centralized piping on left Piping thread type Bore size (mm) Thread type M Rc NPT G Bore size (mm) 10, 15 10 15 25 10 15 25 Symbol Nil 25 TN TF 11 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F Construction A A CY1F15 Detailed
The set values for OUT1 are displayed in auto-preset mode as follows: Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Max. pressure H_1 = (A B)/2 H_1=(A B)/2 B = Min. pressure The display of set values of OUT2 is changed at the number after "_", i.e. "P_2", "n_2" and "H_2". -33No.PS-OMM0003-J [F 9] Power saving mode Power saving mode is selectable.
1.12 1.06 1.00 1.15 0.96 0.91 0.86 0.82 0.77 0.81 0.67 0.64 0.60 0.57 0.54 35 1.40 1.17 1.11 1.05 0.99 0.94 1.08 0.90 0.86 0.81 0.77 0.72 0.76 0.63 0.60 0.57 0.54 0.50 40 Data B Correction factor for temperature (Series IDFS) Inlet air temp. ( C) Outlet air press. dew point ( C) Ambient temp. ( C) 30 35 40 45 50 15 15 15 15 15 10 10 10 10 10 5 5 5 5 5 1.71 1.37 1.09 0.89 0.75 1.31 1.05 0.84
ARM 2 2 3 3 3 4 4 5 5 6 6 2 2 2 3 3 4 4 5 5 6 6 1 2 1 2 3 1 2 1 2 1 2 A B C A B A B A B A B 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC SMC SMC ARP P U Panel mount union Union IR-A IR SMC IRV : Basic size : With reducer
Model XT13-394-06 XT13-394-10 INA-48-1-06 INA-48-1-10 INA-48-16-10 INA-48-16-06 INA-48-58-10-H INA-48-58-06-H Port size Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Relief mechanism Non-relief Relief Non-relief Fluid Deionized water (Pure water) Air, N2 Proof pressure 1.9 MPa 1.5 MPa Max. operating pressure 1.3 MPa 1.0 MPa Set pressure 0.1 to 1.0 MPa 0.05 to 0.5 MPa 5 to 60C Ambient and fluid