SMC Corporation of America
Elite Part Number Search
Search Results "11-LEFS25S2B-100-R2"

JMHZ2-16D-X7400B-HC10-(*) P13P14P15 4 M6 31.5 2XM4x0.7 8 4 M6 108.8L 4 4 M4 4 M3 27 17 10 - JMHZ2-16D-X7400B-HC10DT-(*) 4 M6 32.5 8 4 M6 109.8L 4 4 M4 4 M3 27 17 11 - 3-6. M8 8 M8-Molex P .19 NPN PNP No. 1 +24V DC24V 2 GND DC0V 3 ON/OFF() 4 ON/OFF() 5 () 6 () 7 8 Molex (51227-0800) M8 8 12 - 3-7.

Electroless nickel plate treated is available as option -X2. 11 4. Troubleshooting M series miniature fitting cannot be disassembled or repaired in order to quality maintenance. When failure such as "Insufficient sealing" occurs, please replace the whole product. 12 5.

Construction 11 2 Insert Fitting/KF series Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

In this case, REA32 or larger are applicable. 11 2-3) Relation between Maximum speed and load weight Maximum operating speed limits the load weight. Applied load weight shall be suitable for maximum operating speed or lower than that.

rate (l/min(ANR)) Auto-drain 00 10 11 None 6 72 Float style auto-drain (N.C.)

11 S 8 7 10 15 R 78 97 98 115 P 50 35 45 46.5 AL 1 4, 3 8 1 4, 3 8 144 166 188 230 182 215 281 325 21.5 18 16 18.5 37 37 42 42 3.2 3.2 4.5 4.5 32 40 48 56 28 37 37 44 51 61 66 81 103 121 131 161 10 10 70 70 264 302 370 436 100 120 130 160 180 210 246 290 AMR3000 AMR4000 AMR5000 AMR6000 1 4, 3 8, 1 2 1 4, 3 8, 1 2 1 2, 3 4 1 2, 3 4 3 4, 1 3 4, 1 Adapter assembly installation procedure Accessory

Operating compressor: 0.75 kW (100 l/min (ANR)) or more When using 2 or more auto-drains, multiply the above value by the number of auto-drains to find the capacity of the compressors you will need. For example, when using 2 auto-drains, the compressor capacity with 1.5 kW (200 l/min (ANR)) or greater is required.

Note 7) If the compressor is small (0.75 kW, discharge flow is less than 3.5 scfm (100 L/min[ANR])), air leakage from the drain cock may occur during start of operations. N.C. type is recommended.

The lubrication grease for O-ring and gasket is changed to white vaseline. 11 Main Line Filter Series AFF How to Order AFF37B/75B AFF 37B 10 Body size Made to Order (How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.)

Chamfered port size D (Recommended value) Rc, G NPT, NPTF Female thread size 1 8 1 4 3 8 1 2 10.5 to 11.8 14.1 to 15.8 17.4 to 19.4 21.7 to 25.1 10.2 to 11.8 13.6 to 15.8 17.1 to 19.4 21.4 to 25.1 15-1-11

The EEPROM is rated to keep its memory for 100,000 hours (approx. 11 years) without having power supplied. When system performance declines due to filter element clogging, worn vacuum pads, piping leakage, etc., the switch can detect and indicate an oncoming problem before failure occurs.

OUT2 setting/(CH1 only) MPa or kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE Normally Open Normally Closed SET SET 16-3-11 11 Series PSE530/200 Operation 1: Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE 5 ms 20 ms 160 ms 640 ms SET Press SET button.

CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart.

Integrated display 7 Rated flow range (Flow rate range) Option 2 (Refer to page 907.) 0.2 to 10 (5) l/min 0.5 to 25 (12.5) l/min 1 to 50 (25) l/min 2 to 100 (50) l/min 10 25 50 11 Option 1 (Refer to page 907.) ( ): Fluid: CO2 Calibration certificate Flow adjustment valve None With calibration certificate Nil A Nil S None Yes The certificate is written in English and Japanese.

Troubleshooting 11 6. Construction and parts 1112 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

Mounted on to unused connectors (BUS OUT and PCI). 12 11 10 9 8 6 5 3 1 7 4 2 Direct mounting (1)When joining six or more units, fix the middle part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB1) before mounting using 2-M4x5 screws. Tightening torque: 0.7 to 0.8 Nm. DIN rail mounting (Available for series other than SY series.

Replace the element every 2 years or when the pressure drop becomes 0.1MPa, whichever comes first, to prevent damage to the element. 0.02 0.02 00 00 2000 4000 6000 50 100 150 200 Flow rate L/min (ANR) Flow rate L/min (ANR) AF20 Rc 1/4 AF50 Rc 1 0.10 0.10 P1 = 0.7MPa P1 = 0.5MPa P1 = 0.7MPa P1 = 0.5MPa 0.08 0.08 P1 = 0.3MPa Pressure drop MPa Pressure drop MPa P1 = 0.3MPa P1 = 0.1MPa 0.06 0.06

(Station 1) Light/Surge voltage suppressor Side A: Orange Side B: Green 18.9 (DIN rail dimension) (62.4) ON ON 43.5 OFF OFF (7.5) 34.2 Switch (when equipped with switch) Internal pilot manifold L: Dimensions n: Stations (n1 + n2) External pilot manifold L: Dimensions n: Stations (n1 + n2) L n 2 110.5 100 81 15 L n 2 123 112.5 91.5 16 3 123 112.5 91.5 16 4 135.5 125 102 17 5 148 137.5 112.5

36.5 81.5 40 8 22 99 68 66.5 101 66.5 46 76 24 1/4, 3/8 VCB31 M5 23 25 32 15 13.5 36.5 86 50 8 30 104 68 71 101 71 46 80 24 1/2 M5 23 22.5 36 17 11 41 90 45 8 22 107 70 74.5 103 74.5 48 84 26 1/4, 3/8 VCB41 M5 23 25 36 17 13.5 41 94 50 8 30 111.5 70 78.5 103 78.5 48 88 26 1/2 M5 28.2 30 36 17 17.5 41 102 60 8 35 119 70 86.5 103 86.5 48 96 26 3/4 4 Direct Operated 2 Port for Heated Water

rubber, Conductive NBR, Conductive silicon rubber Series variations ZPT Series ZPR Series Models Lateral vacuum entry Vertical vacuum entry Buffer With buffer With buffer Buffer mounting (male thread) Buffer mounting (male thread) Mounting Female thread Male thread Female thread One-Touch fitting Female thread One-Touch fitting One-Touch fitting Vacuum entry Female thread Dual Page P.10, 11