Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: R (Bracket), Calibration Certificate: A (Calibration
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: None, Calibration Certificate: A (Calibration
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket), Calibration Certificate: A (
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket), Calibration Certificate: A (Calibration
Body Size: 550C, Thread: Rc, Port Size: 10 (1), Accessory: None, Auto Drain: C (N.C. Auto Drain), Drain Guide: None, IN-OUT Direction: None, Element Service Indicator: T (w/Element Service Indicator)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 4 (220VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 7 (240VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 2 (200VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 2 (200VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 6 (3 Position Perfect), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Stations: 10 Stations, Port Size: C4 (ø4 One-touch Fitting), Kit Name: T (Terminal Box), Common: 0 (+COM), Option 1: None, Option 2: D (DIN Rail Mounting), Option 3: N (Name Plate)
Stations: 10 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: 03 (Rc3/8), Thread: Rc (PT), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting)