Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: Built-in, Style: Air Pressure Style, Mounting: Front Flange, Bore Size: 20mm, Stroke: 100mm, Rod Boot: None, Lock Style: Spring Lock (Exhaust Lock), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, Auto Switch Mounting Bracket: -
split [dr E] Display resolution [F 8] [F 9] [PrS] Auto-preset [oFF] Manual Connecting / Disconnecting When mounting the connector, insert it straight into the socket, holding the lever and connector body, and push the connector until the lever hooks into the housing, and locks.
E: Contents revised in several places. [September 2016] F: Contents revised in several places.
Designated nozzle: IBG1-12-10: Nozzle length (50, 100, 150, 300) Silencing nozzle: IBG1-12S Set including the designated nozzle and silencing nozzle: IBG1-12-10-S : Nozzle length (50, 100, 150, 300) 4. Impact resistance of the product is 150[m/s2]. Vibration resistance is 30[m/s2]. Avoid applying vibration exceeding the allowable value to the product. Mounting Warning 1.
[August 2018] E: Contents revised in several places. [June 2019] F: Contents revised in several places. [April 2020] G: Modified errors in text. [October 2020] H: Contents are added.
As a general rule, use 80 to 100 mesh. Although the product has a scraper to prevent foreign matter from entering into the product, fluid containing fine foreign matter such as abrasive powder may cause sealing failure by the foreign matter adhering to the rod sliding part.
E: Contents are added. F: Contents are added. [July 2016] G: Contents revised in several places. [August 2019] H: Modified errors in text. [ November 2019] I: Contents revised in several places.
E: Contents revised in several places. F: Contents are added. [July 2016] G: Contents are added.
Resistance to ground should be 100 ohms or less. A. Single power supply used B. Dual power supplies used Fig. 6 -14No.EX-OMB0014-H Settings Display setting Display Meaning PW LED is ON when the communication power is ON Indicates whether the SI unit is communicating with the master station correctly. LED is ON when the SI unit is receiving normal data from the master station.
ZFC1 ZFC3 ZFC5 ZFC7 5 20 L/min 750 mm 2 7 100 L/min 1260 mm 1 2 2 3.2 3 4 4 6 5 8 6 10 7 12 Inch size A 1/8 B 5/32 D 1/4 E 5/16 F 3/8 7 - 2-2 Specifications Specifications Remarks Fluid Air, Nitrogen This product cannot be used in an environment exposed to chemicals. The maximum operating pressure varies depending on the temperature.
110 83 96 D G C XYA Series / Straight Valve C B Fd (K Flange) 45 H Fn (KF Flange) A E Unit: mm Model n Fd XYA-25 100.2 79.5 48 1 23.5 40 26 64 XYA-40 130 106 66 2 38 55 41 84 XYA-50 178 119 79 2 53 75 52 95 XYA-63 209 149 100 3 61 87 95 70 118 XYA-80 268 178 117 3 80 114 110 83 142 9 XM-OMP0001-A 5.
Electroless nickel plated q w e r t y u i o !0 !1 !2 !3 !4 !5 !