200 Series/Variation Rotary table Series MSU Standard MSU 1.7-1 SMSUl MDSU With auto switch Rotary table Series MSQ MSQ Standard 1.6-1 SMSQl MSQ With auto switch MSQR With shock absorber 5.5-6 World Wide QS\E Support...
To minimize the voltage drop, use 100/200 V AC and 24 V DC wires with the largest sectional areas possible and keep the wiring length as short as possible. 5. The 100/200 V AC wire must not be bundled with or arranged in close proximity with the input/output lines of control terminals or encoder signal lines. If possible, keep a 100 mm or larger distance from such lines. 6.
Closed center SQ1000 SQ1331 33 or less 0.16 0.26 0.58 0.15 0.20 0.64 25 or less Rubber seal 100 SQ1430 26 or less 0.14 0.14 0.60 0.14 0.12 0.58 20 or less Metal seal 100 Exhaust center SQ1431 33 or less 0.19 0.20 0.80 0.15 0.20 0.64 25 or less Rubber seal 100 SQ1530 26 or less 0.14 0.14 0.63 0.14 0.12 0.62 20 or less Metal seal 100 Pressure center Courtesy of Steven Engineering, Inc.-230
) 24 VDC 12 VDC SRP PVQ30 (2.3) SRF 120 ARX20 P = 0.35 MPa 100 P = 0.25 MPa VCHR Flow rate (l/min) 80 P = 0.18 MPa ITV 60 P = 0.1 MPa 40 IC 20 PVQ 0 0 0 20 40 40 80 60 120 80 160 100 200 120 240 140 280 160 320 180 360 200 400 Current (mA) 24 VDC 12 VDC VEF VEP VER PVQ30 (4.0) VEA 120 100 P = 0.12 MPa VY2 Flow rate (l/min) P = 0.08 MPa 80 VBA VBAT P = 0.06 MPa 60 AP100 40 P = 0.04 MPa
/ 100 ft@125 KHz (max.) 0.50 db / 100 ft@500 KHz (max.) 0.70 db / 100 ft@1 MHz (max.)
[1000] 1000 L/min (2000 L type) [P_2 ] Set value of OUT2 [F 2] 3 Page 42 5% of maximums rated flow range [ 25] 25 L/min (500 L type) [ 50] 50 L/min (1000 L type) [ 100] 100 L/min (2000 L type) [H_2 ] Hysteresis of OUT2 [dtH2] ON delay time [0.00] 0.00 s [dtL2] OFF delay time [0.00] 0.00 s [CoL ] Display colour of OUT2 [1SoG] Green when ON, Red when OFF (OUT1) [F 3] [FiL ] Digital filter
PF3A703H (For 3000 L/min) PF3A706H (For 6000 L/min) PF3A712H (For 12000 L/min) 74 No.PF-OMU0002-D Dimensions Symbol Models A B D E F H K L N PF3A703H 130 45 79.1 55.3 22.5 25 35 60 30 4 x M4 x 0.7 depth 7 PF3A706H 170 60 94.1 70.3 30 68 45 80 40 4 x M5 x 0.8 depth 8 PF3A712H 200 70 104.1 80.3 35 85 50 100 50 4 x M6 x 1.0 depth 9 75 No.PF-OMU0002-D Lead wire with M12 connector (ZS-37-A) Pin
Assigning positive value: Input the desired data x 100 in decimal system. Example: +10.50 V is assigned --Assign 10.50 100 = 1050 by PLC. Assigning negative value: Convert the absolute value x 100 that you desire to assign in 16bit binary. Then, change the most significant bit to "1" before inputting.
TAU1065 B Length per roll Color Operating temperature (C) Symbol Length Symbol Color Tubing model 20 100 20 m roll 100 m reel B Black Precautions Be sure to read before handling.
TRBU1065 B 100 Length per roll Tubing model Length 20 m roll 100 m reel Symbol Caution 20 100 1. Applicable for general industrial water. Please consult with SMC if using for the other kind of fluid. Also, the surge voltage pressure must be under the maximum operating pressure. 2. Refer to the burst pressure characteristics curve for other temperatures.
. -9No.EX-OMX1001 Definition and terminology Terms Meaning 100 100BASE-TX Standard of LAN transmission line with communication speed of 100 Mbps. A The signal from the analogue input device is converted to digital, and displayed in decimal and hexadecimal. These hexadecimal and decimal values are also outputted to the analogue output device.
Table 8-1 Water quality criteria for clear water (tap water) Item Unit Standard value For circulating fluid For facility water pH (25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness
46 - DC24VSVON a) b) c) d) e) 47 - D 100 154 1. 2. 3. 4. 5. 6. 7. 8. -10603585% 48 - 155 5 156 49 - 16/ 161 / UL1310Class2 162 ON 50 - 5 () 51 - 163 50mm 164 () 52 - 165 166 D 100 167 53 - Revision history No.JXC-OMT0030CN 2018 3 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are
to 100 kPa -100 kPa 100 kPa 0 to 1 MPa 0 1 MPa -0.1 MPa For positive pressure 0 to 500 kPa 0 500 kPa -50 kPa -13No.PS-OMG0006-D Dimensions PSE5601 , PSE56N01 02 N02 Be sure to release the air in the air tube of the cable to the atmosphere.
E: Contents revised in several places. F: Contents revised in several places. G: Contents are added.[March 2018] H: Contents revised in several places. [June 2018] I: Contents revised in several places.
Supply: PneuAlpha accepts 100-240 VAC or 24 VDC Power Supply for use anywhere in the World. High Current Relay Outputs: Switch currents up to 10 amps with PneuAlphas heavy duty relays. Transistor Outputs: Fast switching, long life Outputs. 100-Hr Capacitor Backup for memory and RTC: PneuAlpha can retain its memory for 100 hours after a power outage.
How to Order 100 TS0604 W Length per roll Color Tubing model Symbol Length Symbol Color Color Symbol 20 20 m roll B Black BU Blue Y Yellow G Green 100 100 m roll (Black and white only) W White R Red Made to Order (Please contact SMC for specifications in detail, dimensions, delivery and specifications other than those mentioned above.) 100 m reel Metric size and Inch size except 16: Suffix
Rotating angle Classification Symbol Single vane Double vane Auto switch 90 180 270 100 190 280 90 100 90 180 270 100 190 280 Nil Without auto switch (built-in magnet) Standard For the applicable auto switch model, refer to the table below.
Piston Speed -X168 Helical insert thread Symbol Specifications Without stroke adjustment unit 25 to 40 Bore size (mm) 100 to 1000 mm/s MY1B Made to Order Click here for details Note 1) 100 to 1000 mm/s A unit L unit and H unit Stroke adjustment unit Note 2) 100 to 1500 mm/s MY1H MY1H Symbol Specifications Note 1) Be aware that when the stroke adjustment range is increased with the adjustment