Body size 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Applicable tubing O.D.
Rated current 6 Branch port C (COM A) 48 52 7 Branch port D (COM D) After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly. Safety cannot be assured in the case of unexpected malfunction.
Plate Cylinder: Double Acting, Single Rod 25, 32, 40, 50, 63 Series MU How to Order B 25 D 30 M Z MU B 25 D 30 Z M S M9BW MDU With auto switch With auto switch (Built-in magnet) Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. Mounting B L F G C D Basic Foot Rod flange Head flange Single clevis Double clevis Auto switch Nil Refer to the below table for applicable auto switch models.
P S I : 0 . 1 N d r a ' . k P a : 1 Ambient and lluid temoeralure 0 to 50'C {with no condensation) Enclosure tP65 Hated pressure I Weight tw10trn ADorox. 250 a {without options) tw20t Aoorox. 350 q (without options) tws0 Aoprox. 645 q (without options) R = ='5 Note 1) Please refer to graph 1, relation lo lhe ditferences belween lhe sel pressure and input.
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked "" are produced upon receipt of order. Do not indicate lead wire length symbol N (none) for types D-A3, D-A44, D-G-39 or D-K39.
The D-A9/M9/P3DW auto switches are shipped together, (but not assembled).
Here, : Deformation ratio (%) d: Tubing diameter (mm) L: Measured length (mm) D: Mandrel diameter (mm) (Twice against the minimum bending radius) Test temperature: 205oC Relative humidity: 655 (%) 100 2d D L 1 = Tube deformation ratio at the minimum bending radius (3) Check the model, type and size before installation.
Element Description EtherCAT connection. 1 (M12 4-pin socket, D-coded) 1 Fieldbus interface connector (BUS OUT) EtherCAT connection. 1 (M12 4-pin socket, D-coded) 2 Fieldbus interface connector (BUS IN) 3 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit. 1 (M12 5-pin plug, A-coded) 4 FE terminal Functional earth.
Dimensions (Hexagon width across flats) Dimensions Min L1 H Screw D D Model Max 20.5 20.5 30 34.2 37 49 ASN2-M5 ASN2-U10/32 ASN2-01 ASN2-02 ASN2-03 ASN2-04 8 8 12(12.7) 17(17.5) 19 24(23.8) 23.3 23.3 35 39.2 42 54 10 10 15 20 25 30 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 Screw D Note) (in parentheses) are the dimensions of NPT screw specifications. Caution Be sure to read before handling.
Nil or M ISE40A MPa Auto-shift Error Connection using One-touch fitting 1. Cut the tube perpendicularly. 2. Hold the tube and insert it into the One-touch ftting slowly until it bottoms out. ZSE40A(F) kPa : After 1 second, the mode will reset to measurement mode. P ISE40A One-touch fitting PSI ZSE40A(F) [F 1] Setting of OUT1 Caution Turn the power off and turn it on again.
How to Order Standard B 20 30 D C CQSY B 20 30 D C F9BW S CDQSY With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
/4 115/1/60 1 NPT 232 R134a 17.7 21.3 19.9 3.3 8.3 82 PDE30-S 137 4.4 5.7 1 230/1/60 1 NPT 174 R134a 21.3 26.4 25 3.1 10.2 126 PDE40-S 137 5.1 6.5 1 1/4 230/1/60 1 1/4 NPT 174 R134a 23.2 32.3 31.7 3.5 11.4 168 PDE50-S 168 6.3 8.2 1 1/2 230/1/60 1 1/2 NPT 174 R134a 23.2 32.3 31.7 3.5 11.4 207 PDE60-S 200 7.2 10.4 1 3/4 230/1/60 2 NPT 174 R134a 23.2 32.3 31.7 3.5 11.4 227 PDE75-S 235 7.5 10.7
Element Description PROFINET connection PORT 2. 1 1 Fieldbus interface connector (BUS OUT/Port2) (M12 4-pin socket, D-coded) PROFINET connection PORT 1. 1 2 Fieldbus interface connector (BUS IN/Port1) (M12 4-pin socket, D-coded) 3 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit. 1 (M12 5-pin plug, A-coded) 4 FE terminal Functional earth.
How to Use DIN Terminal Light/Surge Voltage Suppressor (Pilot Valve: VO307) Disassembly Procedure 1) Loosen screw (1) and pull up housing (2) in the direction of screw (1) to remove the connector from the body (solenoid). 2) Pull out screw (1) from housing (2). 3) On the bottom part of terminal block (3), there is a notch (9).
250 Series DIN terminal: D Terminal: T Applicable cable O.D.:6 to 12 Width across flats 22 Model A B Bs C D E F L M P [inch] Q Grommet: G Grommet: GS Conduit: C Flat terminal: F DIN terminal: D Terminal: T G H G H G H G H G H J G H J XSA1-1P(N) 30 30 66 30 11 20 3 8 1/8 19 27 56.5 30 43 47.5 50.5 23 56.5 64.5 48.5 52.5 99.5 50.5 68.5 XSA2-2P(N) 36 36 79 35 14 22 1/4 24 29.5 68.5 32.5 55
TQ1230001-OM107 1. Parts included in the package Cup mounting flange 1 pc. Parallel pin (6x10): 1 pc. Hexagon socket head cap screw (M6x10): 4 pcs. Suction cup with adapter: 4 pcs. Plug: 1 pc. Plug: 4 pcs. Part No. M-5P Part No. M-3P When Rc1/8 port use as vacuum pressure supply port. Used for decreasing the number of (Mount to unused port.) suction cups. -4No. TQ1230001-OM107 2.
NVEP NVEF 3 1 r T 1 0 3 4 0 T I tffi IFTC I B"dt nowj I Rate rype I I Ports Port Size Code Max. Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.
DXT083-13-1 Qty. 1 pc. VZ Hexagon socket head screw DXT083-19-1 2 pcs.
Product Specifications 3-1. How to order MHM-25D-X7400A-ASSISTA(-P) 6 - 3-2.