5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards3/8?8541/8260

Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Other pressure switches: 0 to 60C Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

(with no freezing) Ambient temperature 0 to 50C Pilot air pressure 0.2 to 0.7MPa Withstand pressure 1.05MPa Recommended operating cycle 1 to 10Hz (0.03 to 1Hz also possible depending on conditions Note 2) Lubrication Not required Voltage 24VDC Weight Mounting position 0.17kg 0.15kg OUT port at top (indication on name plate) 0.2 Note 1) Pilot air solenoid valve recommended Cv factor Each

Additional function Auto shift: Possible to zero clear by input terminal Operating temperature range 0 to 50C (No condensation) Noise resistance 500Vp-p, Pulse width 1s, Standing 1ns Voltage resistance Between external terminal and case 1000V AC, 50/60Hz for 1 min.

ON) Output voltage: 1 to 5V Output voltage: 1 to 5V 2.5% F.S. or less (in rated pressure range) 5% F.S. or less (in rated pressure range) Linearity: 1% F.S. or less Analog output (Note 2) Linearity: 1% F.S. or less Output impedance: Approx. 1kW Output impedance: Approx. 1kW Auto shift input (Note 3) No-voltage input (reed or solid state), input 5ms or more Enclosure IP65 Operating: 0 to 50C

with 25C standard) Temperature characteristics Piping port M5 x 0.8 0 to 50C (With no condensation) Ambient operating temperature Ambient operating humidity 35 to 85% RH (With no condensation) Shock resistance 980 m/s2 X, Y, Z directions, 3 times each Enclosure IP40 (IEC standard) Weight Approx. 100 g (Unit 50 g, batteries 50 g) 2 pcs. of type AA dry batteries (manganese R6 or alkaline

power supply polarity protection) Current consumption 15 mA or less Output specification Analog output 1 to 5 V (Within rated pressure range), Output impedance: Approx. 1 k Accuracy (Ambient temperature of 25C) 2% F.S. or less Linearity 0.4% F.S. or less Repeatability 0.2% F.S. or less Power supply voltage effect 0.8% F.S. or less Enclosure IP40 Operating temperature range Operating: 0 to 50C

VDC (Within rated differential pressure range) Output impedance: Approx. 1 k Output specification Accuracy (Ambient temperature of 25C) Linearity Repeatability Indication light Enclosure Operating temperature range Operating humidity range Withstand voltage Insulation resistance 1% F .S. or less 0.5% F .S. or less 0.3% F .S. or less Orange light is on (When energized) IP40 Operating: 0 to 50C

Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C, other pressure switches: 0 to 60C. Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

output Note 2) Auto shift input Note 3) Enclosure Ambient temperature range Ambient humidity range Withstand voltage Insulation resistance Environmental resistance 10 to 500 Hz at the smaller of amplitude 1.5 mm or acceleration 98 m/s2 (10 G) in X, Y, Z directions for 2 hrs. each (De-energized) 980 m/s2 (100 G) in X, Y, Z directions 3 times each (De-energized) In a temperature range of 0 to 50C

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 VX3 VXA Valve Specifications Fluid Refer to Table (1) on page 17-4-6. 5 to 60C (1) VN VNA A Fluid temperature VNA B 5 to 99C (1) LVC (Air operated type only) Ambient temperature Proof pressure Operating pressure range C 5 to 50C (1) (Air operated type

Not required (Use turbine oil Class 1 ISO VG32, if lubricated. (2)) 5 to 50C (Air operated type: 60C) LVN VNB1 TI/ TIL 2 3 4 VNB 1 4 VNB It is used when the valve is to be operated by the main vacuum in the absence of pressurized air.

LQ Valve specifications Pilot Solenoid Valve Specifications VNC1 SF4--23 VNC2 to 9 Fluid VNCA Model Pilot solenoid valve Coolant 5 to 60C LVN VO301-00T-X302 Grommet Grommet terminal Conduit terminal DIN terminal Fluid temperature 5 to 99C (Air operated type only) VNCB TI/ TIL Conduit terminal Electrical entry 5 to 50C (Air operated type: 60C) Ambient temperature Proof pressure 1.5 MPa 0

0.25 to 0.7 MPa VC Pilot air Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) 5.5 MPa 10.5 MPa Proof pressure Ambient temperature Max. operating frequency Mounting position Port size Orifice size (mm) Flow characteristics Av x 10-5 VDW 5 to 50C 20 times/min Vertical upwards VQ Rc 1 2 Rc 3 8 Rc 3 4 Rc1 Rc 3 8 Rc 1 2 Rc 3 4 Rc1 Rc 3 8 Rc 1 2 Rc 3 4 Rc1 VX2 7.1 86 8.7 110

Note 3) Standard Specifications Metal seal Rubber seal Seal Air, Inert gas Air, Inert gas Fluid Symbol 1.0MPa (3) Max. operating pressure Single 0.20MPa 0.15MPa Valve specifications Solenoid specifications 2 position single 3 position double check Min. operating Double 0.15MPa 0.15MPa (A) 4 (B) 2 (A) 4 (B) 2 pressure 3 position 0.20MPa 0.15MPa (1) (1) 5 to 50C 10 to 50C Ambient and fluid

Low temperature operation Avoid ambient temperatures outside the range of 10C to 50C. At low temperatures, take any necessary steps to avoid solidification or freezing of drainage and moisture. 4. For air blowing applications When using solenoid valves for air blowing, use external pilot type valves.