Thread type Nil Rc F G T NPTF N NPT Port size Symbol Port size C6 6 C8 8 C10 10 C12 12 N7 1/4" N9 5/16" N11 3/8" 02 1/4" 03 3/8" B 1/4" bottom ported Kit type Wiring specifications 2 F, P, T, S (EX126, EX250, EX600) kit 3 L, M, S (EX260, EX500) kit D Double wiring S Single wiring Note 3) Note 3) Single wiring is available only for 1 station.
To rotate the servo motor at 3000r/min in the open collector system (200kpulse/s), set the electronic gear as follows. f CMX CDV = N0 60 10 f : Input pulse frequency [pulse/s] N0 : Servo motor speed [r/min] 200 103 CMX CDV = 3000 60 10 CMX CDV = 3000 60 10 200 103 = 3000 10 60 20 = 15 6 4 11 4.
WH BZ I E 0 0.05 H1 TA 4-TC TB AL A K F H C0. 1 C0. 1 NA BC 8-J BN S + Stroke F ZZ + Stroke e 8 f l ZZ + l + Stroke h + l With rod boot (mm) Stroke range with rod boot Bore size (mm) Stroke range without rod boot Standard Long stroke 20 25 32 40 A AL B1 BC BN BP BZ C D E F GA GB GC GK GL GR GQ H1 I Standard Long stroke 5.5 6 20 to 200 18 15.5 13 38 93 1/8 14 8 12 2 87 10 (12) 18 4 5 26 to
Unit: kg 40 B: 1.05 F: 1.11 B: 1.12 F: 1.18 0.08 0.25 50 B: 1.48 F: 1.54 B: 1.49 F: 1.55 0.11 0.20 63 B: 1.96 F: 2.02 B: 2.06 F: 2.08 0.13 Bore size (mm) Cylinder basic weight Standard Stroke CLK2G series CLK2P series Additional weight per 25 mm stroke Bore size (mm) 40, 50, 63 Standard stroke (mm) 50, 75, 100, 125, 150 Single knuckle joint Double knuckle joint (Pin, cotter pin, flat washer
0 Display units, switch output specifications and diagnostic information selection function 28 F 1 Setting of OUT1 30 F 2 Setting of OUT2 33 F 3 Digital filter setting 35 F 4 Auto-preset function 36 F 6 Fine adjustment of display value 38 F10 Sub display setting 39 F11 Display resolution setting 45 F14 Zero cut-off setting 46 F80 Power saving mode 47 F81 Security code 48 F90 Setting of all
() () ISA3-G () () ISA3-H ON OFF () () ON() OFF() -44No.PS-OMR0001CN-J 4 (1)(100 kPa200 kPa) (2) () (1) (2) 1 () (3) -45No.PS-OMR0001CN-J 4 2 [F 0] [F] 2 2 [][] 2 F 0(Unit) [ PA] kPa 47 ISA3-F[ 20] ISA3-G[ 50] ISA3-H[ 50] F 1(oUt1) OUT1 48 ISA3-F[ 3] ISA3-G[ 20] ISA3-H[ 20] [ SoG] ON OFF F 2(oUt2) () [ ---] 50 F 6( FSt) [ 0.0] 0.0 51 F10( SUb) [ LEvEL] 52 F80
mounting range GB A F K BN Rc(PT) P TB AL 2-TDe8 (pin O.D.)
Mitsubishi Electric Corporation Yaskawa Electric Corporation None F R L T B Nil W Axial Right Left Top Bottom 100/115VAC (50/60Hz) G 1 N.C. (B contact) 2 pcs.
Symbol Bore size 40 to 100 125 to 160 40 to 160 CLQ Rod boot Note) Nil MLGP F Cushion Note) Auto switches are not available with steel tube.
1] Setting of OUT1 (page 28 to) and [F 2] Setting of OUT2 (page 36 to). -22No.PF-OMP0002-H
Order of function settings Order F number Items Notes 1 F 0 Switching function of reference condition, unit selection function, switch output specifications All models 2 F 1 Setting of OUT1 All models 3 F 2 Setting of OUT2 SW2 output type 4 F 3 Digital filter setting All models 5 F10 Sub screen setting All models 6 F14 Zero cut-off setting All models 7 F20 Setting of external input Model
CM2 H L 40 F A J 150 Standard DM2 C H L 40 F A J C73 150 With auto switch Rod boot Without rod boot Nylon tarpaulin Heat resistant tarpaulin Bore size 20mm 25mm 32mm 40mm Air cylinder with auto switch 20 25 32 40 Number of auto switches S n J K 2 1 n Applicable Auto Switches/Refer to p.5.3-2 for further information on auto switches.
Series 2 3 200 Nil Option 300 None F Foot bracket C.O. Valve type Note) The foot bracket is packed with a valve.
Nil Without auto switch B Basic L Axial foot F Rod flange G Head flange C Single clevis D Double clevis T Center trunnion * For applicable auto switches, refer to the table below.
H A F K Rc P TS TR CNG Bracket mounting range BN GB AL TA 2-TDe8 (Pin O.D.)
Order of function settings Order F number Items Notes 1 F 0 Switching function of reference condition, unit selection function, switch output specifications All models 2 F 1 Setting of OUT1 All models 3 F 2 Setting of OUT2 SW2 output type 4 F 3 Digital filter setting All models 5 F10 Sub screen setting All models 6 F14 Zero cut-off setting All models 7 F20 Setting of external input Model
Setting of each function Order Function Item 1 F 0 Display units and switch output specifications 2 F 1 Setting of OUT1 3 F 2 Setting of OUT2 4 F 3 Digital filter setting 5 F10 Sub screen setting 6 F30 Accumulated flow value hold setting 7 F80 Display OFF mode setting 8 F81 Setting of security code -61No.PF-OMW0010-D [F98] Output check The output operation can be forcibly checked.
Setting of each function Order Function Item 1 F 0 Display unit, Switching setting of switch outputspecification and diagnostic information selection 2 F 1 Setting of OUT1 3 F 2 Setting of OUT2 4 F 3 Digital filter setting 5 F10 Sun display setting 6 F30 Accumulated flow value hold setting 7 F80 Display OFF mode setting 8 F81 Setting of security code -63No.PF-OMV0006-B [F98] Output check
(2/4) Alarm operations Alarm threshold and others A.RUN P.RUN A.STP Code Alarm name OFF Display Default setting Settable range Display Set temperature 1.0oC (33.8 o F) (-)5 1.034.0 oC (33.893.2 o F) Monitoring method Circulating fluid drop 0 03 AL04 discharge temp.