Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Nil Built-in magnet No D With auto switch (Built-in magnet) 10 C D M 2 L 40 150 A F Z M9BW 21 C D M 2 L 40 150 A Z M9BW Mounting Basic (Double-side bossed) Axial foot Rod flange Head flange Boss-cut, Basic Boss-cut, Rod flange B L F G BZ FZ Solid state Auto switch M9B, M9BW Reed

Facility water system Electrical system Facility water temperature +27F (15C) Circulating fluid temperature Conditions 50 to 95F (10 to 35C) Facility water temperature 7.9 gpm (30 L/min) 1.1 gpm (4 L/min) 10.6 gpm (40 L/min) 10.6 gpm (40 L/min) Circulating fluid rated flow 5.3 gpm (20 L/min) 2.6 gpm (10 L/min) 10.6 gpm (40 L/min) 6.6 gpm (25 L/min) Facility water required flow rate Temperature

Bore size Auto switch Port thread type 20 25 32 40 50 20 mm Without auto switch (Built-in magnet) Nil 25 mm M5 x 0.8 Nil 32 mm For the applicable auto switch model, refer to the table below. Rc 40 mm TN TF NPT 50 mm G Rear plate Bore sizes 20 and 25: M5 x 0.8 only Nil R Without rear plate With rear plate Cylinder stroke (mm) Refer to Standard Stroke on page 393.

, dual-side D code Plug, Straight 5 m EX9-AC100EN-PSPS: Cable with M12 connector, dual-side D code Plug, Straight 10 m EX9-AC005EN-PAPA: Cable with M12 connector, dual-side D code Plug, Angle 0.5 m EX9-AC010EN-PAPA: Cable with M12 connector, dual-side D code Plug, Angle 1 m EX9-AC020EN-PAPA: Cable with M12 connector, dual-side D code Plug, Angle 2 m EX9-AC030EN-PAPA: Cable with M12 connector

Note EVS Manifold block assembly VZ1000-1A-1 q D side For D side, with D-sub connector and P/R port with One-touch fitting for 6 SUP/EXH block assembly SUP/EXH block assembly VZ1000-2A-1D w VFN For U side, with D-sub connector and P/R port with One-touch fitting for 6 DIN rail VZ1000-2A-1U e End block assembly End block assembly For D side For U side Without D-sub connector For indicated

) 2 (same surface) 2 (different surfaces) 1 3 (same surface) 3 (different surfaces) 2 (same surface) 2 (different surfaces) 1 90 55 50 15 10 105 60 60 15 10 105 65 65 15 10 115 75 65 25 15 35 10 5 45 10 5 40 15 10 45 5 5 30 5 5 55 15 10 40 15 10 60 15 15 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 D-C7 D-C80 D-A7H D-A80H D-H7 D-H7W D-H7BAL D-H7NF Band mounting D-A79W Rail mounting D-F7

Remarks Weight Lead wire and M12 connector LFE-1-A3 Lead wire length: 3 m Approx. 175 g LFE-1-D Tapping screw 3 x 10, 4 pcs. Approx. 45 g Bracket LFE-2-D Tapping screw 3 x 10, 4 pcs. Approx. 70 g LFE-3-D Tapping screw 3 x 10, 4 pcs.

e) 47 - D 100 154 1. 2. 3. 4. 5. 6. 7. 8. -10603585% 48 - 155 5 156 49 - 16/ 161 / UL1310Class2 162 ON 50 - 5 () 51 - 163 50mm 164 () 52 - 165 166 D 100 167 53 - Revision history No.JXC-OMT0030CN 2018 3 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior

Enter together in order, counting from station 1 on the D side. is the symbol for assembly. Add an in front of the part numbers to have solenoid valves, etc. mounted on manifold.

D DL 1 Electrical entry N.O. DIN connector DIN connector with light A surge voltage suppressor is integrated inside the coil as a standard feature. 2 Made to Order 2(OUT) 1(IN) Made to order specifications (For details, refer to page 235) 22.0 MPa 2 Port Air Operated Valve Specifications Response Time 60 VCH42 (N.O.) VCH41 (N.C.)

D-M9B D-M9N, D-M9P D-A93 24 VDC relay, PLC IC circuit, Relay, PLC Relay, PLC 24 VDC (10 to 28 VDC) 28 VDC or less 24 VDC, 100 VAC 2.5 to 40 mA 40 mA or less 5 to 40 mA, 5 to 20 mA Solid state auto switch PLC: Programmable Logic Controller Refer to page 920 for the applicable auto switch list. 905

Applicable tubing O.D. d VCHC ASS ASR ASQ KE TMH M1 L3 L2 L1 D2 Weight (g) D1 Weight (g) D1 L1 L2 L3 L4 M1 M2 Model Tubing O.D. d Model Tubing O.D. d AQ240F-04-04 AQ240F-04-00 12.9 14.3 5.2 39.2 6 4 9.3 5 4 10.0 9.3 39.2 5.2 13.7 23.5 12.9 12.9 AQ240F-06-06 AQ240F-06-00 13.7 15.4 6.2 40.7 8 6 6 10.0 11.6 6 11.6 40.7 6.2 14.7 26.7 13.7 13.7 AQ340F-06-06 AQ340F-06-00 13.7 19.5 6.3 44.8 13 6

C D Can be mounted 2 ways Improves ease of mounting the unit. A B Table running accuracy (mm) The LG1 series provides a stainless steel frame (LG1TH) for customers who required rigidity with an extendable aluminum frame. Refer to page 41 for further details.

Bore size(mm) Auto switch model 20 50 40 32 25 D-M9(V) D-M9W(V) D-A9(V) Note 1) Note 1) Note 1) Note 1) Note 1) BMA3-020 BMA3-025 BMA3-032 BMA3-040 BMA3-050 (A set of a,b,c,d) (A set of a,b,c,d) (A set of a,b,c,d) (A set of a,b,c,d) (A set of a,b,c,d) Note 2) D-M9A(V) BMA3-020S BMA3-025S BMA3-032S BMA3-040S BMA3-050S (A set of b,c,d,e) (A set of b,c,d,e) (A set of b,c,d,e) (A set of b,c,d

Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 0.5 4 0.5 4 3 16 2 16 2 40 5 40 5 2 1 Pin no.

The fixing bolts of cover Bolt type Bolt size Recommended tightening torque (Nm) Quantity M4 x 35 (LEJ40) M4 x 40 (LEJ63) 0.90.1 4 Cross recessed pan head screw Belt (for speed reduction) 8. Troubleshooting When a fault occurs during the operation, the corresponding alarm or warning is displayed.

VR VH VHS Construction VHS20/30 VHS40/40-06/50 6 8 7 2 2 5 5 1 4 IN OUT OUT IN 1 9 3 EXH. EXH. Component Parts No.

Auto switch Bore size Nil Without auto switch (Built-in magnet) 20 25 32 40 50 63 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm For applicable auto switch model, refer to the table below. Port thread type Nil TN TF Cylinder stroke (mm) Refer to Standard Strokes on page 499. Rc NPT G Applicable Auto Switches/Refer to pages 1119 to 1245 for further information on auto switches.