Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: S (-90 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N01 (Screw-in NPT 1/8), EXH: N01 (Screw-in NPT 1/8)

Size, Body, Valve Type: 34B (Size: 3; Body Mat'l: C37; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 2C (110VAC; DIN Terminal w/Surge Voltage Suppressor & Light), Threads: B (NPT Thread)

Size, Body, Valve Type: 34B (Size: 3; Body Mat'l: C37; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 2M (110VAC; Conduit Terminal w/Surge Voltage Suppressor & Light), Threads: B (NPT Thread)

Size, Body, Valve Type: 34B (Size: 3; Body Mat'l: C37; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 2A (24VDC; DIN Terminal w/Surge Voltage Suppressor & Light), Threads: B (NPT Thread)

Size, Body, Valve Type: 34B (Size: 3; Body Mat'l: C37; Port Size: 1/4; Orifice Dia: 8, N.C.), Voltage and Electrical Entry: G (24VDC; DIN Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Threads: B (NPT Thread), Bracket Interchangeable w/Old Type: XB

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Pad Diameter: ø80, Pad Type: H (Heavy-duty, Flat w/Rib), Pad Material: F (FKM), Buffer Body Material: JF (Steel + w/Bushing), Buffer Stroke: 75, Vacuum Inlet Thread Size: N01 (NPT1/8), Mounting Thread Size: A18 (M18 x 1.5)

Pad Diameter: ø125, Pad Type: H (Heavy-duty, Flat w/Rib), Pad Material: F (FKM), Buffer Body Material: JF (Steel + w/Bushing), Buffer Stroke: 25, Vacuum Inlet Thread Size: N01 (NPT1/8), Mounting Thread Size: A22 (M22 x 1.5)

Pad Diameter: ø63, Pad Type: H (Heavy-duty, Flat w/Rib), Pad Material: F (FKM), Buffer Body Material: JF (Steel + w/Bushing), Buffer Stroke: 25, Vacuum Inlet Thread Size: N01 (NPT1/8), Mounting Thread Size: A18 (M18 x 1.5)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m)