Refer to page 101 for details. 1.00 1.00 0.96 Air flow capacity (m3/h [ANR]) Model IDFA15E1 IDFA22E 182 1.04 1.06 1 IDFA37E 273 IDFA55E 390 IDFA75E 660 1.07 1.11 1.03 3C 120 Outlet air pressure dew point 1.1 1.16 1.06 7C 152 231 347 432 720 1.16 1.21 1.09 10C 168 254 382 510 822 1.21 1.25 Air flow capacity (m3/h [ANR]) 1.25 1.27 Model IDFA100F IDFA125F 860 IDFA150F 1045 3C 670 Outlet air
According to the corrected air flow capacity of 48.9 m3/h, the IDFA8E will be selected when the required output air pressure dew point is 3C. The IDFA6E will be selected when the required pressure dew point is 10C. Select the model which air flow capacity exceeds the corrected air flow capacity using the specification table. (For air flow capacity, refer to the data D below.)
MRHQ10C P407090-3C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MRHQ16D P407060-3D MRHQ16S P407060-3S MRHQ16C P407060-3C MRHQ20D P407080-3D MRHQ20S P407080-3S Mounting MRHQ20C P407080-3C Caution MRHQ25D P408080-3D MRHQ25S P408080-3S 1.
MRHQ10C P407090-3C MRHQ16D P407060-3D MRHQ16S P407060-3S MRHQ16C P407060-3C MRHQ20D P407080-3D MRHQ20S P407080-3S Mounting MRHQ20C P407080-3C Caution MRHQ25D P408080-3D MRHQ25S P408080-3S 1. Adjust the rotation angle within the prescribed ranges: 90 10; 180 10 (5 at end of rotation).
MRHQ10C P407090-3C MRHQ16D P407060-3D MRHQ16S P407060-3S MRHQ16C P407060-3C MRHQ20D P407080-3D MRHQ20S P407080-3S MRHQ20C P407080-3C Mounting MRHQ25D P408080-3D Caution MRHQ25S P408080-3S MRHQ25C P408080-3C 1. Adjust the rotation angle within the prescribed ranges: 90 10; 180 10 (5 at end of rotation).
SY3000-54-3C(-Q) SY5000-54-2C(-Q) SY7000-54-3C(-Q) Port size One-touch fitting for 5/16" One-touch fitting for 3/8" One-touch fitting for 3/8" Applicable series SY3000 SY5000 SY7000 SZ VP4 S0700 [When 2 different EXH passages are required.] [When supplying the manifold with 2 different supply pressures.]
(Ambient temperature of 25 3C) Analog output linearity 1% F .S.
Response time (With anti-chattering function) Output short circuit protection Display 2% F .S. 1 digit or less (at ambient temperature of 25 3C) Green LED (OUT1: Lights when ON), Red LED (OUT2: Lights when ON) Output voltage: 1 to 5 V 5% F.S. or less (in rated pressure range) Linearity: 1% F .S. or less Output impedance: Approx. 1 k No-voltage input (Reed or solid state), input 5 ms or more
(Ambient temperature of 25 3C) Analog output linearity 1% F .S.
0D Answer 25.0 deg.C Temperature setting (without writing EEPROM) 2 01 32 02 31 32 35 30 30 03 32 3C 0D 06 32 OD Set at 25.0 deg.C 31 32 Reading internal sensor 2 01 32 05 32 36 39 0D 01 32 02 32 32 35 30 32 03 32 3F 0D Answer 25.02 deg.C 33 Reading external sensor 2 01 32 05 33 36 3A 0D 01 32 02 33 33 30 30 32 03 32 3C 0D Answer 30.02 deg.C 34 Reading alarm status 2 01 32 05 34 36 3B 0D
Examples of commands and answers from the thermo-con (unit specified) Command Command Unit Host requirement Answer from thermo-con code (ASCII code) Content specified (ASCII code) ASCII 31 Reading setting temperature 2 01 32 05 31 36 38 0D 01 32 02 31 32 35 30 30 03 32 3C 0D Answer 25.0 deg.C 31 Temperature setting (without writing FRAM) 2 01 32 02 31 32 35 30 30 03 32 3C 0D 06 32 OD Set
Data Maximum Settable Temperature Graph 1: IDH4 Graph 2: IDH6 F 50F (10C) 44.6F (7C) 41F (5C) Pressure dew point 37.4F (3C) 50F (10C) 44.6F (7C) 41F (5C) Pressure dew point 37.4F (3C) Air flow capacity scfm (L/min [ANR]) 17.6 (500) 28.3 (800) Air flow capacity scfm (L/min [ANR]) 15.9 (450) Selection example 24.7 (700) 14.1 (400) 21.2 (600) 12.4 (350) Selection example Selection example 10.6
Piping port thread ty pe Rc Rc C2SL-6-A C2SL-6C-A G G NPT C2SL-6(Z)-A NPT C2SL-6C(Z)-A Semi-standard symbol 3 36 3C 36C Semi-standard: 3 Semi-standard: 3C (7) Part No. Piping port thread ty pe Piping port thread ty pe (7) Part No. Rc Rc C2SL-3-D C2SL-3C-D G G NPT C2SL-3(Z)-D NPT C2SL-3C(Z)-D Appearance and part No.
assembly 1 2 position single 2 2 position double SY9000-37-4B 3 3 position closed center For 110VAC (115VAC) 4 3 position exhaust center Specification Single solenoid Double solenoid/ 3 position SY9000 SY9000-37-1C 5 3 position pressure center Pilot specification SY9000-37-2C A, B port size Nil Internal pilot External pilot R Single solenoid with spacer assembly Symbol Port size C8 SY9000-37-3C
If the circulating fluid temperature falls below 3C, the pump will start operating automatically. The heat generated by the pump operation will warm up the circulating fluid. When the temperature rises above 5C, the pump will stop automatically. As a result, the circulating fluid maintains a temperature of between 3C and 5C, preventing freezing. 2.
P407090-1 P406090-3D MRHQ10D Switch holder B P406090-3S MRHQ10S P407060-1 P406090-3C MRHQ10C Switch case P406060-3D MRHQ16D P406060-3S MRHQ16S P406060-3C MRHQ16C P407080-3D MRHQ20D P407080-3S MRHQ20S Switch holder A P407080-3C MRHQ20C P408080-3D MRHQ25D Two of each part indicated at the left are included in a unit. Switches are not included with a unit.
SY3000-54-3C(-Q) SY5000-54-2C(-Q) SY7000-54-3C(-Q) Applicable series 10-SY5000 10-SY3000 10-SY7000 10-SY5000 10-SY7000 [When supplying the manifold with 2 different supply pressures.] [When 2 different EXH passages are required.]