(Refer to the table below) Default setting Model (Output specification) OUT1 OUT2 A NPN NPN B PNP PNP C NPN Analogue 1 to 5 V D NPN Analogue 4 to 20 mA E PNP Analogue 1 to 5 V F PNP Analogue 4 to 20 mA L PNP L2 PNP PNP L3 PNP Analogue 1 to 5 V L4 PNP Analogue 4 to 20 mA -35No.PF-OMZ0002-A [F 0] Selection of reference condition, unit selection function, switch output specifications.
(Displays 0 when the value is (Displays 0 when the value is below 10 L/min) below 20 L/min) 20 to 1050 L/min 40 to 2100 L/min 2.0 0 to 2%F.S. (Displays 0 when the value is (Displays 0 when the value is below 20 L/min) below 40 L/min) 30 to 1050 L/min 60 to 2100 L/min 3.0 0 to 3%F.S.
Change of Parameters for Initial Operation 20 Initial Adjustment 20 1.Selection of calibration mode 20 2.
Setting of analogue output (voltage output only) Press the UP or DOWN button to select 1 to 5 V output or 0 to 10 V output. : Only 4 to 20 mA is available for current output. The display will be [4-20] and not settable. Press the SET button to set. Move on to analogue free range mode setting.
For ISA3-G type, the range is up to 280, with a hysteresis of 20.
20 15 15 10 10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz) 0.1 10 Circulating fluid return 0.0 0 0 10 20 30 40
Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to
10 5 2.86 20 10 5 Parameter *1,*2 Para.
Bar stock type 20 S Y E Valve Series Efsvsooo ] EI SYsOOO I -svzooo ] None Foot (Sinole solenoid onl Side Type of Actu.
Both sdes (2 to 20 siaiions) '!
E 03 05 07 09 't't 5132" 1l4', 5/16' 3t8" 1/2" 6mm 8mm H , T , U , X , N 1 3 06 08 t0 1 2 1 6 32 i10-32 UNF Thread 3 5 I l t N P r H ' L . W , r .
1 -57No.EX-OMN0027CN-D (Range) (Lwr_Lmt) (Upr_Lmt) -10..10 V -10.50+10.45 V -10.45+10.50 V -5..5 V -5.25+5.22 V -5.22+5.25 V -20..20 mA -21.00+20.90mA -20.90+21.00mA 0..10 V 0.00+10.45 V +0.05+10.50 V 0..5 V 0.00+5.22 V +0.03+5.25 V 1..5 V +0.75+5.22 V +0.78+5.25 V 0..20 mA 0.00+20.90mA +0.10+21.00mA 4..20 mA +3.00+20.90mA +3.10+21.00mA -58No.EX-OMN0027CN-D (1) No.
Pressure Loss Fluid: Water HED003 35 30 Pressure loss kPa 25 HED003-HW13 20 15 10 HED003-HW19 5 0 0 2 4 6 8 10 12 14 16 18 20 Flow rate L/min Fig.9-13 Recirculating fluid Pressure loss (HED003) HED005, HED007 35 30 Pressure loss kPa 25 HED005-HW13 HED007-HW13 20 15 10 HED005-HW19 HED007-HW19 5 0 0 2 4 6 8 10 12 14 16 18 20 Flow rate L/min Fig.9-14 Recirculating fluid Pressure loss (HED005
Symbol Stations 02 20 20 2 stations 20 stations Specify the valve stations not exceeding the maximum stations. SUP/EXH block fitting spec.
Caution: Connection of any output to another voltage supply will bridge the safe output switch and cause an undetected error. 20 No.EX##-OMY0004 4.
Do not use a cable longer than 20 m. Wire the DC(-) line (blue) as close as possible to the power supply.
PROFIsafe PROFIsafe 20 "PROFIsafe PROFINET 16.3.
Conductor size (mm2) Overall diameter (mm) Colour of cover SMC product No. (1 pc.) 0.8 to 1.0 Red ZS-28-C 26-24 0.14-0.2 1.0 to 1.2 Yellow ZS-28-C-1 (28) (0.08) 1.2 to 1.6 Orange ZS-28-C-2 1.0 to 1.2 Green ZS-28-C-3 1.2 to 1.6 Blue ZS-28-C-4 22-20 0.3-0.5 1.6 to 2.0 Gray ZS-28-C-5 Do not cut the insulator.