200 10 125 15 15 + 55(n-2)/2 n = 2, 4, 6, 8 20 20 + 55(n-2)/2 n = 2, 4, 6, 8 20 20 20 + 55(n-2)/2 n = 2, 4, 6, 8 25 25 + 55(n-2)/2 n = 2, 4, 6, 8 10 100 35 100 + 100(n-2) n = 2, 3, 4, 5 35 + 30(n-2) n = 2, 3, 4, 5 10 55 35 55 + 55(n-2) n = 2, 3, 4, 5 35 + 30(n-2) n = 2, 3, 4, 5 10 10 + 40(n-2)/2 n = 2, 4, 6, 8 10 10 + 40(n-2)/2 n = 2, 4, 6, 8 10 10 + 30(n-2)/2 n = 2, 4, 6, 8 15 10 + 45(n
Ambient temperature (C) Recommended circulating fluids 10 to 45 Tap water, ethylene glycol aqueous solution 15(wt)% -5 to 10 Ethylene glycol aqueous solution 15(wt)% -20 to -5 Ethylene glycol aqueous solution 40(wt)% Circulating fluid temperature(C) Recommended circulating fluids 10 to 35 Tap water, ethylene glycol aqueous solution 15(wt)% 5 to 10 Ethylene glycol aqueous solution 15(wt)%
Request message to write (from master) 02 31 30 57 53 56 31 30 30 32 30 30 03 51 Address BCC data End code Start code Request to write Numerical data Identification code Response message from the product 02 31 30 06 03 06 Affirmation code Start code Address End code BCC data Code Symbol/Data ASCII code Start code STX 02H Address 10 31H 30H Required content W (write) 57H Identifier SV1
8.5 13 10.5 12 9.5 10 9.5 13.5 11 13 10 10.5 9.5 14.5 12.5 14 11 9.5 10 14.5 13 14 11 9.5 11 15.5 14.5 15 12 8 12 9.5 11 10 8.5 13 10.5 12 9.5 10 9.5 13.5 11 13 10 10.5 9.5 14.5 12.5 14 11 9.5 10 14.5 13 14 11 9.5 11 15.5 14.5 15 12 CHM CHS CH2 CH2 CHA CH2F (mm) Auto switch model Bore size (mm) 32 Related Products 40 50 63 80 100 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59/F59F
TdH9 TB +0.036 0 +0.036 0 +0.043 0 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 42 48 53 60 10 10 10 10 5.5 5.5 6.6 6.6 31 37 38.5 42.5 40 47 47 55 20 25 32 40 36 43 50 58 10 10 10 10 5.5 5.5 6.6 6.6 25 30 35 40 (29.3) (33.1) (40.4) (49.2) 8 10 12 14 8 10 12 +0.043 0 14 CG-020-24A CG-025-24A CG-032-24A CG-040-24A Applicable bore size (mm) Applicable bore size (mm) Part no.
Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 http://www.smcworld.com 2016 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing UR printing UR 11030SZ Printed in Japan. D-G
Refer to "LECSB2-T Operation Manual (Simplified Edition)", section 5.7 for how to set the Point table. -32- LEY63 LEY63D Lead symbol A B C L A B C Series Lead 5(2.86) 20 10 5 20 10 5 (Including pulley (Pulley ratio 4/7) ratio) Parameter *1,*2 Para.
No.VEX-OMY0001 1) 2) 3) 1.351.45Nm P8,9 02 03 04 02 03 04 04 06 10 10 12 01 02 01 02 14 20 VEX312VEX322VEX332VEX342VEX350VEX370VEX390( ) VEX1-18-1A VEX5-32A VEX7-32A VEX9-32A ( ) VEX1-18-2A VEX3-32-2A P2 AN120-M5 AN103-01 AN210-02 1) VEX1-9-1P VEX4-2A-P VEX1-11-2 VEX4-4 DXT152-14-1A NXT013-3 VO307K-1 2) 3) VEX322 VEX342 Rc A 1/8 1/4 F G VVEX2 VVEX4 B 1/4 3/8 N NPT ( ) VEX1-17
G Stainless steel Body material Applicable tubing O.D. 04 06 08 10 12 4 6 8 10 12 Body size 2 Elbow Type 2 3 4 5 6 M5 1/8 1/4 3/8 1/2 Control type Port size 0 1 Meter-out Meter-in M5 01 02 03 04 M5 x 0.8 R1/8 R1/4 R3/8 R1/2 With one-touch fitting 1
Request message to write (from master) 02 31 30 57 53 56 31 30 30 32 30 30 03 51 Numerical data Address BCC data End code Request to write Identification code Start code Response message from the product 02 31 30 06 03 06 Address End code BCC data Affirmation code Start code Code Symbol/Data ASCII code Start code STX 02H Address 10 31H 30H Required content W (write) 57H Identifier SV1
Orifice size (mm) 2 3 4 5 7 10 Symbol 2 3 4 5 7 10 Class 3 Class 2 Class 4 Electrical entry G Grommet C Conduit Refer to the below table for orifice and port size combinations.
) 02 D type DIN connector D Rated coil voltage 3/8 (AVL3000) 03 Port size D type DIN connector with indicator light & suppressor Manual lockout Nil 3(R) DZ 1/2 (AVL4000) 04 B A G 100VAC (50/60Hz) 1 3/4 (AVL5000) 06 D type DIN connector with M12 connector, indicator light & surge voltage suppressor AVL2000 push button protrudes by 1mm over the body. 200VAC (50/60Hz) 2 DZM 1 (AVL5000) 10 110
P211070-10 P211090-10 P211060-10 P211080-10 P211010-10 P211070-10 P211090-10 P211060-10 P211080-10 P211010-10 Model CDRB2BWU10 CDRB2BWU15 CDRB2BWU20 CDRB2BWU30 CDRB2BWU40 CDRBU2WU10 CDRBU2WU15 CDRBU2WU20 CDRBU2WU30 CDRBU2WU40 CDRB1BW50 Series CRB1 Single/Double type CDRB1BW63, 80, 100 Series CRB2 Solid state switch for size 10 and 15 requires no switch block, therefore the unit part no.
20 30 40 0 0 10 20 30 40 0 10 20 30 40 0 10 20 30 40 0 10 20 30 40 0 10 20 30 40 0 10 20 30 40 0 10 20 30 40 0 10 0 10 20 30 40 [] Circulating fluid temperature[] Circulating fluid temperature[] Circulating fluid temperature[] Circulating fluid temperature[] Circulating fluid temperature[] [] Circulating fluid temperature[] Circula Circulating fluid temperature[] 50Hz 60Hz 60Hz 50Hz 50Hz
/20. 9-1 9.1.2 HRR010-W-10/20. 9-3 9.1.3 Refrigerant with GWP reference . 9-5 9.1.4 Communication specification . 9-5 9.2 Outline dimensions . 9-6 9.2.1 HRR010-A-10/20. 9-6 9.2.2 HRR010-W-10/20. 9-7 9.3 Flow Chart . 9-8 9.3.1 HRR010-A-10/20. 9-8 9.3.2 HRR010-W-10/20. 9-8 HRR Series HRX-OM-X084 Contents 9.4 Cooling capacity . 9-9 9.4.1 HRR010-A -10. 9-9 9.4.2 HRR010-W-10. 9-9 9.4.3 HRR010-
B B When D-F8 is used Size: 10 to 200 B A Reed switch Solid state switch Size 10 20 30 50 70 100 200 Rotation A B Actuation range A B Rotation range m Actuation range Rotation range m 36 50 66 68 78 91 115 10 190 90 10 90 40 54 60 72 82 95 19 21 27 31 37 41 48 61 17 23 27 33 37 44 57 190 80 10 80 10 10 65 10 190 65 10 10 50 190 50 10 190 45 10 45 Operating range at proper mounting position
Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.
Bore size/Stroke (mm) Bore size 6 10 15 20 25 32 Standard strokes 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 Applicable Auto Switches/Refer to page 15 for detailed auto switch specifications.
, IDF6E-10 IDF8E-10, IDF11E-10 Type 100 V 10 A IDU3E-10, IDU4E-10 IDU6E-10 30 mA IDF4E-20, IDF6E-20 IDF8E-20, IDF11E-20 Type 200 V 5 A IDU3E-20, IDU4E-20 IDU6E-20 S Option symbol IDF1E-10 to 11E-10, IDU3E-10 to IDU6E-10 With power cord connection The option allows the connection of a power cord to a terminal block.