View A 1 2 3 4 5 6 7 8 Analog output 1 to 5VDC 8 7 6 5 4 to 20mADC 5 20 Analog output [mA] Analog output [V] 1 4 Max. measured flow rate value Real-time flow rate [l/min] Min. measured flow rate value Min. measured flow rate value Max. measured flow rate value Real-time flow rate [l/min] Standard condition Standard condition Basic condition Basic condition Minimum measured Maximum measured

Metric sizes Inch sizes Body class 3 1/8 3/16 4 1/4 8 3/8 10 12 19 1/2 3/4 6 1 2 3 4 5 v v v V V V V v v V V v v V V V v v V v V v Note) Refer to page 505 for information on changing tubing sizes. Specific Product Precautions Be sure to read before handling.

VVEX4-2-6-A VEX3420 5 pcs. VEX4-5 1 pc.

1 . 4-1 4-2 . 4-1 4-2-1 . 4-1 4-2-2 . 4-1 4-2-3 . 4-2 5 5-1 . 5-1 5-2 . 5-3 1 6 6-1 . 6-1 6-2 GWP . 6-1 6-3 . 6-2 6-4 . 6-3 6-5 . 6-4 7 C 7-1 . 7-1 7-2 . 7-1 8 K 8-1 . 8-1 8-2 . 8-1 9 L 9-1 . 9-1 9-2 . 9-1 9-3 (ADH4000-04) . 9-2 9-4 . 9-2 10 R 10-1 . 10-1 10-2 . 10-1 10-3 . 10-1 10-4 . 10-2 10-5 . 10-2 11 T 11-1 . 11-1 11-2 . 11-1 11-3 . 11-1 11-4

) With 4 selftapping screws Note) ISO228 compliant Port size Port size Rated flow range 501 102 No 04 * 1/2 * bracket Output specifications OUT1 OUT2 A B C D NPN PNP NPN NPN PNP PNP NPN PNP NPN PNP Analog 1 to 5 V Analog 4 to 20 mA Note) Each option is not assembled with E Analog 1 to 5 V the product, but shipped together.

. 5-4 5.7 Setting method . 5-5 5.7.1 IP Address Setting . 5-6 5.7.2 Setting of subnet mask and default gateway. 5-7 5.8 Communication sequence. 5-8 5.9 Message configuration . 5-8 5.10 Function codes . 5-9 5.11 Explanation of function codes . 5-10 5.12 Register Map . 5-11 5.12.1 Circulating fluid discharge temperature . 5-13 5.12.2 Circulating fluid electrical conductivity . 5-13 5.12.3

10 ZB1-VPN3A KJ H 04 04 C2 2 H 02 2 C4 4 L 04 4 N1 1/8" 01 1/8" N3 5/32" 03 5/32" L2 2 4 L4 4 LN1 1/8" LN3 5/32" -N KJL04-C1-N 10 Assy ZB1-FE3-A 30m ZA ** 10 1 0-101kPa15V 2%F.S ZA ZB1-SE1-A 3 -100100kPa15V 2%F.S.

VP717 AC40-A Y400-A Y400T-A E400-04-A AN40-04 AN402-04 * Refer to page 3 for details of the spacer. 1 Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve VP500/700 Series Specifications Fluid Air Type of actuation N.C.

Plug lead unit for VQD1000 poppet valve, Maximum 20 stations available as standard, 4 port sizes available, MFLD, 5-STA, VALVE, VV4QD15 MANIFOLD VQD 4/5 PORT, UJ, VV4QD15 BUILT IN FITTING .19800 lb, .19800 lb

Plug lead unit for VQD1000 poppet valve, Maximum 20 stations available as standard, 4 port sizes available, MFLD, 5-STA, VALVE, VV4QD15 MANIFOLD VQD 4/5 PORT, 1J, VV4QD15 OTHER SIZE RATING, .19800 lb

Red 4 Lock B-1 Black 5 Lock A-1 Brown 1 Sensor B-3 Blue 2 Sensor A-3 Electric Actuator side Controller side 11 - (5) Communication plug connector -5 4 Correspondence network Type 3 2 CC-Link MJ Straight type S 1 T T-Branched Straight type type 5 No.

Display and setting of various functions . 5-1 5.1 List of function . 5-1 5.2 Function. 5-2 5.2.1 Key operations . 5-2 5.2.2 List of parameters . 5-4 5.3 Main screen . 5-7 5.3.1 Main screen . 5-7 5.3.2 Display on the main screen . 5-7 5.4 Alarm display menu . 5-8 5.4.1 Alarm display menu . 5-8 5.4.2 Content of display of alarm display menu . 5-8 5.5 Inspection monitor menu . 5-9 5.5.1 Inspection

(Including O-ring for element) 5 m 10 m 20 m Model FH150-02 FH150-03 FH150-04 Element size EP910-005N EP910-010N EP910-020N 55 x 90 Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type. N: Petroleum, V: Phosphoric ester, W: Water-glycol, Emulsion (10 m only) Note 2) Refer to page 528 for micromesh elements.

(A)4 2(B) 4(A) 2(B) 6 0.91 V 3(EB) (EA)5 1 (P) 24 VDC 5(EA) 3(EB) 1(P) JSY3000 N.O. valve x 2 pcs. 3-position closed center (A)4 2(B) 2(B) 4(A) 8 2.77 V V 10 (EA)51 3(EB) (P) 3(EB) 5(EA) 1(P) JSY5000 3-position exhaust center N.C. valve, N.O. valve x 1 pc. of each 2(B) 4(A) (A)4 2(B) 12 6.59 V V 12 (EA)51 3(EB) (P) 3(EB) 5(EA) 1(P) V Standard v Option G Made to Order Manifold Options MIndividual

n.07 Motor-load position error 0.01 V/1 reference unit Positioning completed: 5 V Positioning not completed: 0 V n.08 Completion indicated by output voltage.

V 2-wire 100 V, 200 V Reed switch Solid state switch 3-wire (NPN) Terminal conduit 2-wire 3-wire (NPN) Relay, PLC IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 3-wire (PNP) 2-wire 12 V 24 V 3-wire (NPN) Grommet IC circuit 5 V, 12 V 12 V 5 V, 12 V Water resistant (2-color indication) 3-wire (PNP) 2-wire IC circuit With diagnostic output (2-color indication) 4-wire (

RHC Load voltage 24 VDC 100 VAC 200 VAC Load current range (2) 5 to 50 mA 5 to 25 mA 5 to 12.5 mA MK(2) Contact protection circuit Built-in Internal voltage drop RS Q G 2.4 V or less (to 20 mA)/3.5 V or less (to 50 mA) Indicator light Auto Switch Internal Circuit D-A33C Red LED lights when ON.

F9BWV Relay, PLC 2-wire IC circuit No 5 V, 12 V 100 V or less 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) IC circuit 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL 5 mZ (Example) M9NZ Solid state switches marked with are produced upon

If using other screws, switch may be damaged. (3) Load current range and Maximum load current 5 to 20 mA 5 to 40 mA 20 mA Contact protection circuit None D-A93 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA) D-A93V 2.7 V or less Internal voltage drop 0.8 V or less Auto Switch Internal Circuit Colors of lead wire inside ( ) are the ones before conformed to IEC standard.