Silver (S1) MS Solid yellow (Y1) Clear yellow (Y2) KKA Neon yellow (Y3) KP Clear orange (YR1) Neon orange (YR2) LQ Nominal size (inch) 1 4 " 3 16" 1 8 " 3 8 " 1 2 " 5 32" 5 16" MQR Nominal size (mm) T T 3.2 IDK Fluid Air/Water 20C 0.8 Max. operating pressure (MPa) Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually.
Nil S MHW -X Tool stand MA210 Y59A S1 MRHQ MA Tool stand DAuto switch type Lead wire length Without auto switch Nil Nil L Grommet With 0.5 m lead wire With 3 m lead wire D-Y59A (3-wire) Y59A Solid state auto switch Lead wire: Axial direction entry D-Y59B (2-wire) Y59B 741
P1 LED lever meter Sensor S1 S3 Red is on: Output OFF Green is on: Output ON S4 S2 + P2 Red 1 Gap too big S1, S2: Fixed orifice S3: Variable orifice (Set via adjustment knob) S4: Detection nozzle Red 2 Green 1 BEST POSITION The bridge circuit is constructed as shown in the diagram. Position the work piece in front of the nozzle (S4).
To represent an AND function: OUTPUT = S1 AND S2 To represent a NAND function: OUTPUT = NOT (S1 AND S2) Very complex arrangements can also be coded in this manner. Options: AND, OR, NOT, XOR Inputs 1> 2> 3> 4> Output ON/OFF 6 1 PneuAlpha Function Blocks 6 6.2 The SET/RESET Block This block can act as either a SET or RESET latch upon receipt of a signal.
G Note) Float switch specifications Voltage Max. cut off capacity Max. cut off current Contact Level indication 200 VAC, 200 VDC 12 VA AC, 10 W DC 0.6 A AC, 0.5 A DC 1a, 1b Bottom limit indication PPA How to Order AL ALB 900 0 0 10 S1 Float switch (Option) Booster lube Operation control signal Nil S1 S2 900 2 inch standard None 1b (Without oil ON) 1a (Without oil OFF) Body size 0 1 2 4 5
P1 Sensor S1 S3 S2 S4 P2 S1, S2: Fix orifice S3: Variable orifice (adjusted by setting dial) S4: Detection nozzle 16-8-6 7 Series ISA2 Air Catch Sensor Internal Circuit and Wiring Circuit and Wiring for 2 Port Solenoid Valve NPN open collector output DC (+) Without indicator light DC circuit Without display light AC Circuit OUT Main circuit of switch Main circuit of switch Load 1 DC (+) 1
Series: VP500, Body: Base Mounted, Pilot: Internal Pilot, Voltage: 24 VDC, Electrical Enty: DIN Terminal, Light/Surge Suppressor: w/Light/Surge Voltage Suppressor, Port Size: 3/8", Thread: Rc, Safety Limit Switch/Wiring: M12 Connector, Made by Rockwell Automation, with Check Valve, External Pilot Only: Check Valve: None; Applicable Tube: None, Throttle: Variable Throttle
Series: 5 (VP500), Body: 4 (Base Mounted), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Electrical Enty: D (DIN Terminal), Light/Surge Suppressor: Z (w/Light/Surge Voltage Suppressor), Port Size: 03 (3/8"), Thread: Rc, Safety Limit Switch/Wiring: S1 (M12 Connector, Made by Rockwell Automation), with Check Valve, External Pilot Only: Check Valve: None; Applicable Tube: None, Throttle: Variable
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 20 (2), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: Rc, Port Size: 14 (1 1/2), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 120 to 12000 l/min, Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 2, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -
Rated Flow Range: 30 to 3000 l/min, Thread Type: Rc, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -
Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: Rc, Port Size: 1 1/2, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -
Rated Flow Range: 120 to 12000 l/min, Thread Type: NPT, Port Size: 2, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: R (Right to Left)
Model: 7 (VP700), Pilot: R (External Pilot), Pressure Specifications: Nil (Standard (0.7MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: YZ (EN 175301-803C terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: M (M12 connector, made by OMRON), Flow Direction: Nil (left to right), No. of Residual Pressure Exhaust Valves: S (Single), Soft Start-up: S