Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Locking Slotted Style), Port Specification: Side Ported, Port Size: 03 (3/8), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 4 (220 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: F (G)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Extended Style), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: E (Grommet Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: N (NPT)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Locking Slotted Style), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Locking Lever Style), Port Specification: Side Ported, Port Size: 06 (3/4)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: N (NPT)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Locking Slotted Style), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: T (NPTF)
4/5 PORT SOLENOID VALVE. Valve, 5 Port Solenoid. 2.6 lb. I42.
4/5 PORT SOLENOID VALVE. Valve, 5 Port Solenoid. 1.72 lb.
Series VXP pilot operated 2 port solenoid valve for air, gas, steam, water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, class B or class H coils, brass, BC6, or stainless steel body materials and NBR, FPM, EPR, PTFE seal materials., "VALVE, 2 PORT VALVE
4/5 PORT SOLENOID VALVE. Valve, 5 Port Solenoid. 897 lb. I42.
Series VXP pilot operated 2 port solenoid valve for air, gas, steam, water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, class B or class H coils, brass, BC6, or stainless steel body materials and NBR, FPM, EPR, PTFE seal materials., Valve, Media, 2 PORT VALVE, 1330 lb
Series VXP pilot operated 2 port solenoid valve for air, gas, steam, water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, class B or class H coils, brass, BC6, or stainless steel body materials and NBR, FPM, EPR,, Valve, Media, 2 PORT VALVE, 1330 lb
Series VG342 is a 3 port pilot poppet solenoid valve and can be used as a selector or divider valve (external pilot). Actuation is changeable between N.C., N.O., or external pilot types. VG342 is possible to use in vacuum or under low pressures. No lubrication is required. 3 port pilot operated poppet valve , Material restriction type , Low power consumption: 4.8W DC (standard type); 2W