Max. voltage (with no load): 30 Vrms (42.4 V peak) or less Max. current: (1) 8 A or less (including shorts), and (2) When controlled by a circuit protector (fuse, etc.) with the following rating Max. current rating No-load voltage (V peak) 5.0 0 to 20 [V] 100 Over 20 [V] to 30 [V] Peak voltage value 2) A circuit (class 2 circuit) with maximum 30 Vrms (42.4 V peak) or less, and a power supply
Q VXF25B< VXF26B< VXF27B< VXF28B< 20 20 20 20 20 20 20 20 108 111 111 111 100 103 103 103 30 30 30 30 52.5 52.5 52.5 52.5 20 20 20 20 94.5 97.5 97.5 97.5 17 2 Port Solenoid Valve For Dust Collector Series VXF2 Dimensions: Flange type VXF25B<<26B<<27B<<28B<<< Conduit terminal Conduit B B A A C C S S E J Qp2 Tp2 R J R Q z280 24.4 I K 1/2 Exhaust port K 1/2 Exhaust port I 24.4 U (32) L
The total number of solenoids (points) must not exceed 20. SOL.A 1A () (+) SOL.B Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B () (+) 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL.A 2A () (+) Station 2 SOL.B 2B () (+) 1.
Driver Inrush currents (A0-P) Main circuit power supply (L1, L2, and L3) Control circuit power supply (L11 and L21) LECSS2-T5/ LECSS2-T7/ LECSS2-T8 30 A (attenuated to approx. 3 A in 20 ms) 20 A to 30 A (attenuated to approx. 1 A in 20 ms) LECSS2-T9 34 A (attenuated to approx. 7 A in 20 ms) Since large inrush currents flow in the power supplies, always use molded-case circuit breakers and
II Air Cylinder Drive Systems Total Stroke Time and Speed at the End Series SV Series SV1000 Applicable bore size: 20, 25, 32, 40 Applicable related components Total stroke time s Solenoid valve Tubing Speed controller Silencer 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 200 CM2 20 50% 70% 10% 30% 150 Stroke mm AS2201F -01-06 AS2200-01 70% 100 50 10% 30% 50% 0 200 CM2 25 150 Stroke mm AS2201F
Stick terminal: Size 1.5 or shorter (Example) 2000 mm lead wire length DC AC VP342-5LO1-01A VP342-1LO1-01A V200-30-4A-20 V200-30-1A-20 Ground nut Set screw Tightening torque Tightening torque 0.5 to 0.6 Nm 2.5 to 3.75 Nm Washer Housing Grommet (Rubber) Terminal block Terminal screw 3 locations Tightening torque 0.4 to 0.5 Nm + (Location for light mounting) (Polarity indication) (Voltage
Symbol Stations 02 20 20 2 stations 20 stations Specify the valve stations not exceeding the maximum stations. SUP/EXH block fitting spec.
(P980) . 20-19 20.4.4 Identification & Maintenance (I&M) . 20-20 20.4.5 Reset To Factory . 20-21 20.5 STATE TRANSITION . 20-22 20.5.1 Basic State Machine . 20-22 20.5.2 FSA state . 20-25 20.5.3 Controlword/Statusword . 20-27 20.5.3.1 Controlword . 20-27 20.5.3.2 Statusword . 20-30 20.6 CONTROL MODE . 20-36 20.6.1 Selection of control mode . 20-36 20.6.2 Control switching . 20-37 20.6.3 Profile
(b) OFF ON OFF 63.4% CDT = 100 ms 100 50 100 4.00 10.00 4.00 120 84 120 3000 4000 3000 20 50 20 1 50 60 50 1 50 60 50 1 0.20 0.15 0.20 1 0.20 0.15 0.20 2 20 30 20 2 20 30 20 2 0.10 0.05 0.10 2 0.10 0.05 0.10 (2) (a) PB06 GD2 4.00 [] PB08 PG2 120 [rad/s] PB09 VG2 3000 [rad/s] PB10 VIC 20 [ms] PB29 GD2B 10.00 [] PB30 PG2B 84 [rad/s] PB31 VG2B
4 x 30 5 x 10 5 x 20 Symbol Breadth x Length (mm) 5 x 30 6 x 10 6 x 20 6 x 30 8 x 20 8 x 30 3507 4010 4020 4030 5010 5020 5030 6010 6020 6030 8020 8030 ZF ZP ZCU Dimensions AMJ Series ZPT Series ZPR Series ZPY Misc.
15 63 70 183 79 2 11 75 52 20 17.5 68 88 217 100 3 11 87 95 70 20 20 72 90 256 117 3 11 114 110 83 20 26.5 98 108 321 154 3 11 134 130 102 20 38 133 138 335 200 3 11 190 180 153 30 40 114 Note 1) Dimension E applies when heater option is included.
ON-flow 0.04 40 B p ipe pe 3/4 B p pi 3B 30 1 0.03 2B, pipe 20 0.02 , 5B , 4B pe 1/4 1 B pi 10 Max.
or less VFR2100 VFR2110 1 8 1 4 10 Double 20 or less VFR2200 VFR2210 1 8 1 4 1 8 1 4 1 8 1 4 Closed center 5 30 or less VFR2300 VFR2310 0.43 (0.45) Exhaust center 5 30 or less VFR2400 VFR2410 0.43 (0.45) Pressure center VFR2500 VFR2510 5 30 or less Note 1) [ ]: Denotes the normal position.
XLS-16XLS16-20-G, C, T, D XLS-16-P XLS16-20-PG XLS-25XLS25-20-G, C, T, D XLS-25-P XLS25-20-PG Description Construction No. w y r e-1 e-2 Coil assembly Core assembly Armature assembly O-ring O-ring XLS25-30-1 XLS25-30-2 AS568-018V AS568-030V XLS16-30-1 XLS16-30-2 AS568-018V AS568-025V 465 b
With lead wire ZS-20-A ZS-20-5A-50 0.6 m 3 m 5 m Nil 30 50 (The flow characteristics are for the supply pressure of 0.5 MPa.)
No. 136126A Relieving type 136126A Diaphragm assembly A Weather resistant NBR, POM 136126-1A 136126-1A Non-relieving type Valve B HNBR, Aluminum alloy 136127-30#1 136127-30#1 Valve spring C 136131 Stainless steel 136131 136137-30 Gasket D HNBR 136137-30 NBR 136146 Standard model 136146 O-ring E HNBR 136146-30 Oil-free specification 136146-30 NBR 136147 Standard model 136147 O-ring F HNBR
No. 136126A Relieving type 136126A Diaphragm assembly A Weather resistant NBR, POM 136126-1A 136126-1A Non-relieving type Valve B HNBR, Aluminum alloy 136127-30#1 136127-30#1 Valve spring C 136131 Stainless steel 136131 136137-30 Gasket D HNBR 136137-30 NBR 136146 Standard model 136146 O-ring E HNBR 136146-30 Oil-free specification 136146-30 NBR 136147 Standard model 136147 O-ring F HNBR
Max. voltage (with no load): 30 Vrms (42.4 V peak) or less Max. current: (1) 8 A or less (including shorts), and (2) When controlled by a circuit protector (fuse, etc.) with the following rating Max. current rating 5.0 100 Peak voltage value No-load voltage (V peak) 0 to 20 [V] Over 20 [V] to 30 [V] 2) A circuit (class 2 circuit) with maximum 30 Vrms (42.4 V peak) or less, and a power supply
(up to 24 solenoids possible) 20 20 20 stations 20 stations Connector mounting position Mounting position Symbol D PG: Flat cable connector (20 pins) PH: Flat cable connector (10 pins) D Side Note Symbol 02 Note Symbol 02 Stations Stations 2 stations 2 stations ... ... ... ...
25 30 4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated steam holding heat (kcal/kg).