SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-41-06-M5"

MLU ML1C Auto switch mounting screw M5 x 0.8 x 16 l 1.

With bracket a Option w Note) Applicable to 90-AF40-06, 90-AFM40-06 and 90-AFD-40-06.

The lead wire entry is on D side (LD) in this case. 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread Note) 3 position types need two stations.

OPTIONS AND AUXILIARY EQUIPMENT (b) Surge protector RAV-781BYZ-2 [Unit: mm] 1) 2) 3) Black Black Black 5.5 1 11 1 4.2 0.2 28.5 1.0 28 1.0 UL-1015AWG16 200 30 0 1 3 2 4.5 0.5 41 1.0 RAV-781BXZ-4 [Unit: mm] 1) 2) 3) 4) 5.5 1 11 1 28.5 1.0 200 30 4.2 0.2 UL-1015AWG16 0 28 1.0 1 3 2 4.5 0.5 41 1.0 11 34 12. ABSOLUTE POSITION DETECTION SYSTEM 12.

HEP Related Equipment Port size A Stroke range (mm) 5 to 30 A' B C d D E F FK FL FY GA GC Model Air port Vacuum port M5 x 0.8 M5 x 0.8 M5 x 0.8 16.5 Note 1) Note 2) ZC(D)UKQ16 ZC(D)UKQ20 ZC(D)UKQ25 ZC(D)UKQ32 M5 x 0.8 M5 x 0.8 11 12.5 20 32 2 6 7 8 13 17 28 19 12 5 to 50 14 18 22 26 32 40 40 50 62 3 4 5 8 10 12 9 10 11 8 10 12 16 20 24 20 22 29 33 43.5 51.5 19 21.5 23 21.5 22 22.5 M5 x 0.8

Model Elbow type Straight type In-line type 12-REA25 10-AS2001F-06-X214 10-AS2201F-01-06-X214 10-AS2301F-01-06-X214 12-REA32 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 6. Do not use the cylinder with its body fixed. Be sure to secure both head covers (or end covers in case of CY1R) before using the cylinder.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

12 13 7 9 7 10 M5 set screw (1 pc.) 44 12 24 30 88 64 43 16 M5 12 13 9 9 10 10 Y-type double knuckle joint Bracket pin 20: Y-020B 25: Y-032B 32: Y-04D 40: Y-04B 2 x D drill through RR1 RR1 C1 Chamfer NDH10 NDH10 MM C E1 E1 C1 Chamfer NZ NZ NX NX A1 A1 U1 L1 A B U1 L1 Material: Carbon steel Material: Cast iron Material: Rolled steel Part no.

36.5 13.5 15 32 25 23 M5 24 59 46 57 60 54.5 48.5 101 57 68 1/2 22 45 89 41 11 17 36 22.5 23 M5 26 64.5 48 62.5 62 60 50.5 103 62.5 70 1/4, 3/8 VCW41 30 50 93.5 41 13.5 17 36 25 23 M5 26 66.5 48 64.5 62 62 50.5 103 64.5 70 1/2 35 60 101 41 17.5 17 36 30 28.2 M5 26 70 48 68 62 65.5 50.5 103 68 70 3/4 4 Direct Operated 2Port for Water Series VCW Dimensions (N.O.)

36.5 13.5 15 32 25 23 M5 24 59 46 57 60 54.5 48.5 101 57 68 1/2 22 45 89 41 11 17 36 22.5 23 M5 26 64.5 48 62.5 62 60 50.5 103 62.5 70 1/4, 3/8 VCW41 30 50 93.5 41 13.5 17 36 25 23 M5 26 66.5 48 64.5 62 62 50.5 103 64.5 70 1/2 35 60 101 41 17.5 17 36 30 28.2 M5 26 70 48 68 62 65.5 50.5 103 68 70 3/4 4.5-6 Direct Operated 2Port for Water Series VCW Dimensions (N.O.)

36.5 13.5 15 32 25 23 M5 24 59 46 57 60 54.5 48.5 101 57 68 1/2 22 45 89 41 11 17 36 22.5 23 M5 26 64.5 48 62.5 62 60 50.5 103 62.5 70 1/4, 3/8 VCW41 30 50 93.5 41 13.5 17 36 25 23 M5 26 66.5 48 64.5 62 62 50.5 103 64.5 70 1/2 35 60 101 41 17.5 17 36 30 28.2 M5 26 70 48 68 62 65.5 50.5 103 68 70 3/4 4 Direct Operated 2Port for Water Series VCW Dimensions (N.O.)

KFV-04 KFV-06 KFN-04 KFN-06 KFW-04 KFW-06 KFS-04 KFS-06 4/2.5 6/4 KFV-08U 8/5 KFV-08N 8/6 KFV-10U 10/6.5 KFV-10N 10/7.5 KFV-12U 12/8 KFV-12N 12/9 4 6 KFN-08 8 KFN-10 10 KFN-12 12 4/2.5 6/4 KFW-08U 8/5 KFW-08N 8/6 KFW-10U 10/6.5 KFW-10N 10/7.5 KFW-12U 12/8 KFW-12N 12/9 4 6 KFS-08 8 KFS-10 10 KFS-12 12 Precautions Be sure to read before handling.

M5 x 0.8 x 5 M5 x 0.8 x 5 How to install cover assembly Remove machine screw M48 x 2 M48 x 2 ( ): Port size is R , , 13-14-12 12 Related Products: Air Line Equipment Air Filter, Regulator, Filter Regulator, Mist Separator Modular, Air filter Series AF Flow rate (l/min (ANR)) Bowl capacity (cm3) Filtration degree ( m) Port size Rc Model AF10 AF20 AF30 AF40 AF40-06 AF50 AF60 150 1100 2600

10 16 4.3 2-3.2 Mounting holes Manual override 24.5 7.8(C3, C4, C6) (M5: 5.7) Cover dia 1.6 Cross section 0.34mm2 (Lead wire) 34 35 300 (53) 27.5 16.3 18 1.2 13.8 13.6 7 (7.8) (24.5) 2-3.4 Mounting holes 41 Foot bracket M5 X 0.8 P port M5 X 0.8 R port R 3 P 1 10.7 9 M5 X 0.8 External pilot port 32 (Only external pilot style (R)) L plug connector (L): VQZ115-lLl-C3, C4, C6, M5-PR M plug connector

/O.D. mm 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Symbol M5 01 02 03 04 06 Symbol 23 04 06 08 10 12 16 Symbol 50 60 65 80 85 110 167 Series KK Flow Characteristics Air (0 to 1 MPa) Water (0 to 0.4 MPa) KK2 KK2 0.007 0.50 Series KK2 (KK2S-M5M + KK2P-M5M) Series KK2 (KK2S-M5M + KK2P-M5M) 0.45 0.006 0.40 0.005 0.35 Flow rate m3/min (ANR) Flow rate m3/min Flow rate m3/min 0.30 0.004 0.25 0.003 0.20

) P=10.5 13.5 (L3) 3 L2 6 .5 L1 2 1 16 .5 Station 5.5 D side 2.3 2-M5 X 0.8 External pilot port (Only external pilot style(R)) 7.8(C3, C4, C6) 21.6 (M5: 5.7) 35 5.5 53 300 (Lead wire) Cover dia 1.6 Cross section 0.34mm2 (Top piping) 39.5 7.8 42.5 P R 1 3 15 8 2-M5 X 0.8 PE port 13.4 2-Rc(PT)1/8 R(EXH) port 16.3 The broken line indicates DIN rail mounted style [-D]. 41.2 2-Rc(PT)1/8 P(SUP)

BA 32 BA 04 BA 05 BA 06 BA 08 BA 10 BA 01 BA 02 BM1 01 BM1 02 BM1 32 BM1 04 BM1 05 BM1 06 The following stainless steel mounting screw kits (including set screws) are available for use depending on the operating environment. (Order the mounting band separately, as it is not included.)

Note 2) When compressor discharge oil mist concentration is 30 mg/m3 (ANR). 11 Related Products Series PB Filter Regulator + Mist Separator Air Combination Model Specifications Model AC20D AC30D AC40D AC40D-06 AC20D AC30D AC40D-06 AC40D Model 1.5 MPa 1.0 MPa Proof pressure Series AC20D/30D/40D Filter regulator Component devices AW20 AW30 AW40 AW40-06 Max. operating pressure 0.05 to 0.85 MPa

Symbol Size 04 4 06 6 08 8 10 10 12 12 16 16 Use the part number below to order the gasket for M5 thread. Gasket for M5 thread: M-5G2 E Bulkhead union v v Bulkhead connector v v A KQ2 H 06 00 1 4, 6 (Oval type release button) Oval type release button KQ2 H 08 00 A 8 to 16 (Round type release button) Port size/Applicable tubing O.D.