Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
: A3 (Bracket C), Operation Manual: K (Operation Manual, Calibration Certificate)
Model: 520 (2.0 to 16.0 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), I/O Specifications: A3 (IN1: 0-10 VDC, IN2: External Control Input, OUT1: 0-10 VDC), Lead Wire: C (Lead Wire with M12 connector, 3m, Bracket: R (with Bracket), Operation Manual: Z (with Operation Manual)
Model: 504 (0.5 to 4.0 L/min), Thread Type: N (NPT), Port Size: 03 (3/8), I/O Specifications: A3 (IN1: 0-10 VDC, IN2: External Control Input, OUT1: 0-10 VDC), Lead Wire: C (Lead Wire with M12 connector, 3m, Bracket: R (with Bracket), Operation Manual: Z (with Operation Manual)
Model: 520 (2.0 to 16.0 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), I/O Specifications: A3 (IN1: 0-10 VDC, IN2: External Control Input, OUT1: 0-10 VDC), Lead Wire: C (Lead Wire with M12 connector, 3m, Bracket: R (with Bracket), Operation Manual: Y (None)
Size: 4 (3/8), Cleaning Grade: 1 (B Grade: Ultrasonic Cleaning), Pressure Setting: 0 (0.02 to 0.2MPa), Relief Function: 0 (Non-relieving), Thread: N (NPT), Port Size: 03 (Rc 3/8), Direction of Gauge Port: R (Right)
Size: 4 (3/8), Cleaning Grade: 1 (B Grade: Ultrasonic Cleaning), Pressure Setting: 0 (0.02 to 0.2MPa), Relief Function: 0 (Non-relieving), Thread: Rc(PT), Port Size: 03 (Rc 3/8), Direction of Gauge Port: R (Right)
Size: 4 (3/8), Cleaning Grade: 1 (B Grade: Ultrasonic Cleaning), Pressure Setting: 0 (0.02 to 0.2MPa), Relief Function: 0 (Non-relieving), Thread: N (NPT), Port Size: 04 (Rc 1/2), Direction of Gauge Port: R (Right)
Size: 4 (3/8), Cleaning Grade: 1 (B Grade: Ultrasonic Cleaning), Pressure Setting: 0 (0.02 to 0.2MPa), Relief Function: 0 (Non-relieving), Thread: Rc(PT), Port Size: 04 (Rc 1/2), Direction of Gauge Port: R (Right)
Size: 3/8, Cleaning Grade: B Grade: Ultrasonic Cleaning, Pressure Setting: 0.02 to 0.2MPa, Relief Function: Non-relieving, Thread: NPT, Port Size: Rc 3/8, Direction of Gauge Port: Right
Size: 3/8, Cleaning Grade: B Grade: Ultrasonic Cleaning, Pressure Setting: 0.02 to 0.2MPa, Relief Function: Non-relieving, Thread: Rc(PT), Port Size: Rc 3/8, Direction of Gauge Port: Right
Size: 3/8, Cleaning Grade: B Grade: Ultrasonic Cleaning, Pressure Setting: 0.02 to 0.2MPa, Relief Function: Non-relieving, Thread: NPT, Port Size: Rc 1/2, Direction of Gauge Port: Right
Size: 3/8, Cleaning Grade: B Grade: Ultrasonic Cleaning, Pressure Setting: 0.02 to 0.2MPa, Relief Function: Non-relieving, Thread: Rc(PT), Port Size: Rc 1/2, Direction of Gauge Port: Right
Output data Offset Meaning MSB LSB MSB LSB (INT) 15 8 7 0 D4 #D3 #D2 #D1 #C4 #C3 #C2 #C1 #B4 #B3 #B2 #B1 #A4 #A3 #A2 #A1 Slave 8 connection diagnosis 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 In the figure above, #A1 to #A3 are slaves for which the connection is diagnosed. In this case, #A3 slave is not connected, and a diagnostic error is generated.
(Tolerance 30%) 5.3-11 Reed Switch/Band Mounting D-A33/D-A34/D-A44 Applicable Actuator Series Terminal conduit: D-A3 DIN terminal: D-A4 Series Bore size (mm) CDA1, CDBA1, CDV3, CDVS, CDLA, 40, 50, 63, 80, 100 CE2, CNA CDL1 40, 50, 63, 80, 100, 125, 140, 160 CDS1 125, 140, 160, 180, 200 RHC 20, 25, 32, 40 Specifications PLC: Programmable Logic Controller D-A3 (With indicator light) Terminal
(mm) Auto switch model Bore size 50 63 80 100 125 32 40 D-A3/A44 D-G39/K39 BMB2-040 BMB1-050 BMB1-063 BMB1-080 BMB1-100 BMB2-032 BS1-125 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5F D-F5BAL D-F5NTL BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 BT-08 D-P5DWL D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W D-Y7WV D-Y7BAL BMB3T-040 BMB3T-040 BMB3T-050 BMB3T-050 BMB3T-080 BMB3T-080 BAP2T-080 BMB4-032 BMB4-050 BMB4-050
(5.7) 15 16 11 30.7 114 [820m] A B-1 2 A A-1 1 L B B-2 6 B A-2 5 8 8m COM-A/COM B-3 3 COM-B/ A-3 4 A 10m B 15m Shield Vcc B-4 12 C 20m GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 8 3 4 B-1 5 A-1 1 B-3 2 A-3 2 1 (5.5) 14 18 (6.3) B1 A1 5 6 17.7 14.2 A6 B6 B1 A1 10.2 2 1 B3 A3 (5.7) 15 16 11 30.7 45 - 115 I/O No.
NPN Type PNP Type I/O signal power I/O signal power CN5 CN5 24VDC 24VDC A1 COM A1 COM A2 COM A2 COM A3 IN0 A3 IN0 A4 IN1 A4 IN1 A5 IN2 A5 IN2 A6 IN3 A6 IN3 A7 IN4 A7 IN4 A8 MODE A8 MODE A9 SETUP A9 SETUP A10 HOLD A10 HOLD A11 DRIVE A11 DRIVE A12 RESET A12 RESET A13 SVON A13 SVON B1 OUT0 Load B1 OUT0 Load B2 OUT1 B2 OUT1 Load Load B3 OUT2 B3 OUT2 Load Load B4 OUT3 B4 OUT3 Load Load B5 OUT4