SMC Corporation of America
Elite Part Number Search
Search Results "SGHA130A-30N10-B1"

Bore size (mm) 32 40 50, 63 80, 100 125 GKM10-20 GKM12-24 GKM16-32 GKM20-40 GKM30-54 +0.5 +0.15 +0.5 +0.15 +0.5 +0.15 +0.5 +0.15 +0.5 +0.15 M10 x 1.25 10 40 10 10 52 20 20 12 12 62 M12 x 1.25 12 48 24 24 16 16 83 M16 x 1.5 16 64 32 32 M20 x 1.5 20 80 20 20 105 40 40 M27 x 2 30 110 30 30 148 54 55 Piston Rod Ball Joint KJ (ISO 8139) l l3 d6 (Max.) l d3 b1 h12 h d1 H9 l3 Part no.

Applicable bore size SNJ-016C SNKJ-016C 10 16 C1 d C2 d B1 B2 H1 H2 14 17 16.2 19.6 4 4 7 8 8.1 9.2 3.2 4 M10 x 1.0 M12 x 1.0 M4 x 0.7 M5 x 0.8 The applicable mounting nuts are different from those for standard cylinders. 7 B CJ2W-Z Series 10-/1121-/22Double Rod Cylinder 10, 16 How to Order Clean series 10 11 Relief type Vacuum suction type M9BW Z 60 16 L W 2 J D C 10 B M9BW Z 60 16 L

Fittings & Tubing Air Cylinders Rotary Actuators d C2 C1 B2 H2 B1 H1 Material: Carbon steel (mm) Material: Carbon steel (mm) Part no. Applicable bore size Part no.

CS1 Bore size (mm) e Part no. b d f h11 l1 c a GKM10-20 10 +0.50 +0.15 32 40 10 20 20 M10 x 1.25 52 C76 +0.50 +0.15 GKM12-24 12 48 12 24 24 40 M12 x 1.25 62 +0.50 +0.15 GKM16-32 16 64 16 32 32 50, 63 M16 x 1.5 83 C85 +0.60 +0.15 M20 x 1.5 GKM20-40 20 80 20 80, 100 105 40 40 C95 CP95 NCM NCA D-X 20Piston Rod Ball Joint KJ (ISO 8139) Steel Data Bore size (mm) d3 Part no. d1 H9 h d6 (max) b1

B1 B2 B3 CN d1 d2 d3 E FL H (Max.) L1 l1 (Min.) l2 R SR (Max.)

Basic (Through-hole/Both ends tapped common): CQUB F Q 2 x M5 x 0.8 Y 4 x M6 x 1 depth 10 4 x 5.4 through 15 KA H H1 Rod end nut Width across flats B1 NY EY D X C1 K NX A + Stroke B + Stroke L EX L1 Rod end male thread Basic (mm) Size Stroke range (mm) A B D EX EY F H K KA L NX NY Q Y 20 25 32 40 5 to 50 49 42.5 10 22 47 11.5 M5 x 0.8 depth 8 5 8 6.5 5.5 36 15 3 5 to 50 49 42.5 10 24 53 11

D-F9BAL Bore size (mm) D 18.5 16 9 6 4 3.5 B 2 9 12 14 14.5 C 0.5 10.5 16.5 24 25 34 A 18.5 28.5 34.5 42 43 52 D6 10 15 20 25 32 A C Electrical entry direction: Inward Electrical entry direction: Outward -X 20Auto Switch Mounting Dimensions CXSJ6/10 Data C3 Bore size (mm) 6, 10 0.4 0.4 7.2 4.8 7.2 4.8 B1 Symbol Auto switch model C2 D2 D1 A1 B1 C1 C2, C3 D1 D2 D-A9 D-F9 W, D-M9 C1 A1 D-A9V

A C Auto switch mounting dimensions Note 2) A3 Note 3) B1 A2 B2 (mm) Bore size 6, 10 0.4 0.3 0.4 0.3 A1 Symbol Auto switch model A1 A2, A3 B1 B2 D-A93 D-A93 (Reed switch) D-M9 (Solid state switch) D-M9 Specific product precautions Be sure to read before handling.

b3 f l l3 j g b e C d6 l Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com h (mm) (mm) f g c j a Bore Model Thread d3 M4 x 0.7 M4 x 0.7 M6 x 1 M6 x 1 M8 x 1.25 M10 x 1.25 dh7 h 27 27 30 30 36 43 d6 18 18 20 20 24 28 b3 b1 l 10 10 12 12 16 20 d7 11 11 13 13 16 19

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bore size (mm) E B1 B2 B3 TG1 T I1 (min) I2 FL H d1 d2 d3 CN SR (max) R 32 14 34 3.3 3 5 22 10 30 10 45 32.5 5.5 10.5 6.6 11 17 40 16 40 4.3 4 5 25 10 35 12 55 38 5.5 11 6.6 13 20 50 21 45 4.3 4 5 27 10 40 16 65 46.5 6.5 15 9 18 22 63 21 51 4.3 4 5 32

1362213623Description Individual Note 1) In the case of A1 and B1, a pressure gauge or a plug is mounted on the body side, while in case of A2 and B2, on the manifold side.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bore size (mm) E B1 B2 B3 TG1 T I2 FL d2 d3 CN R H SR (max) d1 I1 (min) 32 5 5.5 30 10.5 6.6 11 14 34 3.3 3 22 10 17 45 10 32.5 40 5 5.5 35 11 6.6 13 16 40 4.3 4 25 12 20 55 10 38 50 5 6.5 40 15 9 18 21 45 4.3 4 27 16 22 65 10 46.5 63 5 6.5 45 15 9 18

D-F9BAL Bore size (mm) D 18.5 16 9 6 4 3.5 B 2 9 12 14 14.5 C 0.5 10.5 16.5 24 25 34 A 18.5 28.5 34.5 42 43 52 D6 10 15 20 25 32 A C Electrical entry direction: Inward Electrical entry direction: Outward -X 20Auto Switch Mounting Dimensions CXSJ6/10 Data C3 Bore size (mm) 6, 10 0.4 0.4 7.2 4.8 7.2 4.8 B1 Symbol Auto switch model C2 D2 D1 A1 B1 C1 C2, C3 D1 D2 D-A9 D-F9 W, D-M9 C1 A1 D-A9V

D-F9BAL Bore size (mm) D 18.5 16 9 6 4 3.5 B 2 9 12 14 14.5 C 0.5 10.5 16.5 24 25 34 A 18.5 28.5 34.5 42 43 52 D6 10 15 20 25 32 A C Electrical entry direction: Inward Electrical entry direction: Outward -X 20Auto Switch Mounting Dimensions CXSJ6/10 Data C3 Bore size (mm) 6, 10 0.4 0.4 7.2 4.8 7.2 4.8 B1 Symbol Auto switch model C2 D2 D1 A1 B1 C1 C2, C3 D1 D2 D-A9 D-F9 W, D-M9 C1 A1 D-A9V

Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com KA (manual unlocking unit) Dust cover NH1 M(D)LUB25,32 (Extension locking) K H2 P ZZ1 + Stroke GB GA Unlocks when pressurized BP unlocking port Front cylinder port GC D GW GY NH (manual unlocking unit) Dust cover P Rear cylinder port NS + Stroke NG NF NJ NJ NI Width across flats KA MM Width across flats B1

Model B3 C1 14 20 22 C2 39 44 54 E1 1 1 1 E2 1 1 1 B1 28 40 44 78 88 108 96 111 131 MY-J25 MY-J32 MY-J40 8-11-29 29 Series MY1B Floating Bracket Facilitates connection to other guide systems. Applicable bore size Floating Bracket Operating Precautions Caution Make sure that the amount of divergence from the external guide is within the adjustable range.

(adjustable range) 2 x 2-LD MY3 Floating Bracket Mounting Dimensions (mm) Adjusting range Applicable cylinder Model Common JJ L P LD H G Ea Eb MYAJ16 MYAJ25 MYAJ40 MYAJ63 MY316 MY325 MY340 MY363 M4 x 0.7 M6 x1 M8 x1.25 M10 x1.5 1 1 1 1 1 1 1 1 38 55 72 100 20 22 32 40 4.5 5.5 6.5 9.0 10 12 16 19 6.0 9.5 11.0 14.0 Applicable cylinder Model Mounting direction q C1 D1 F1 K1 10 11 16 20 Q1 B1

Part Number Description: SEAL GASKET   Product Line: E   Product Line Description: AIRLINE EQUIPMENT   Family Code: 139   Family Description: FLOW CONTROL W/FITTING   Class Code: B1   Part Code: 2   Reference Code:  J   Click here to report information errorImage shown may not match exact part number

Short circuit of L + power supply or C/Q terminal or P24. 4 L#B1 Turn off the power to the unit and then turn it on again. If the error is not eliminated, stop using the product and contact your SMC sales representative. An internal memory error has occurred in the IOLink master unit. Red and green LEDs are ON alternately.

Brackets Accessary i Symbol Contents B1 EXW1-NT1 For the following EX600-W models EX600-WEN1/2 EX600-WPN1/2 EX600-WSV1/2 EXW1-AB1 B2 EXW1-NT1 For the EXW1 series EXW1-AB2 As the brackets and the NFC Reader/Writer worsen the performance of wireless communication in the 2.4 GHz band, use them only during configuration and remove them during normal operation.