Flow switch Blue (DC COM) Brown (24 VDC) Terminal No. 14 Brown (24 VDC) 6 Terminal No. Flow switch 5 Terminal No. Blue (DC COM) 11 Terminal No. Black (Output 1) 3 Terminal No.
[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.
Description Size Quantity BBA2 1 Auto switch mounting screw M3 x 0.5 x 6 L 1 BMU1-025 M3 x 0.5 x 8 L 1 BQ-1 M3 x 0.5 x 10 L 1 BQ-2 2 Auto switch mounting nut (Hexagon nut) M3 x 0.5 1 BQ-1 3 Auto switch mounting nut (Convex shape) M3 x 0.5 1 BQ-2 D-A7, A8 D-F7, J7 * A spacer for BQ-2 (black resin) is not included. * When using D-A9l(V)/M9l(V)/M9lW(V)/M9lA(V) auto switches with BQ2-012, use
How to Order Needle Valve/Flow Rate Characteristics 0 2 F A 1 AS 1 M3 X790 06 AS1201F-M350 45 40 35 30 25 20 15 10 5 0 0.5 0 1 1.5 2 2.5 3 3.5 4 4.5 5 6 7 8 Inlet pressure: 0.5 MPa Port size Push-lock type Body size Flow rate [L/min (ANR)] 1 M3 x 0.5 M3 M3 x 0.5 Applicable tubing O.D.
(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.
With brake: 148 Without brake: 118 Housing With brake: 135 Without brake: 105 29 24.6 Thread size M3 x 0.5 6 4 45 M4 x 0.7 8 2 46 Effective thread length (mm) Quantity P.C.D.
VX021S-1-16FB 12 VDC 100 VAC 110 VAC 200 VAC C18312G6GCU None 220 VAC 230 VAC 240 VAC 24 VAC 48 VAC 24 VDC GDM2A-L5 12 VDC GDM2A-L6 100 VAC GDM2A-L1 110 VAC GDM2A-L1 200 VAC GDM2A-L2 220 VAC GDM2A-L2 230 VAC GDM2A-L2 240 VAC GDM2A-L2 24 VAC GDM2A-L5 48 VAC GDM2A-L15 With light * Select an appropriate DIN connector suitable for the coil insulation type. 7 XSA Series Specific Product Precautions
Electrical specifications Item Specifications Current consumption of controller power supply 21.6 to 26.4 VDC 0.1 A max.
x 0.5 9.5 3.4 6.5 3.3 5 7 5.5 10.5 26 23 34 15 7.5 M3 3.5 10 M3 x 0.5 11.5 3.4 6.5 3.3 5 7 7 13 33 30 38 15 7.5 M3 3.5 12 M4 x 0.7 18 4.5 8 4.4 4.5 6.5 7.5 14.5 38.5 35.5 53 17 8.5 M4 4.5 14 M4 x 0.7 16.5 6 4 45 14 62 29 14.5 M3 4.5 26 6.5 7 34 3 M5 x 0.8 20.5 7 4 51 17 70 29 14.5 M4 5.5 31 8 8 39 3 M6 x 1 21 7.5 4.5 62.5 22 76 34 17 M5 6.5 41 9.5 10 50 3 M6 x 1 25.5 7.5 7.5 74.5 28 90 39
IDFB Corrected air flow capacity = 31 m3/h (0.83 x 0.83 x 0.92) = 48.9 m3/h Obtain the corrected air flow capacity from the following formula. Corrected air flow capacity = Air consumption (Correction factor A x B x C) IDH 3 ID Select the model. According to the corrected air flow capacity of 48.9 m3/h, the IDFA8E will be selected when the required output air pressure dew point is 3C.
D-A93 D-M9B D-M9N Load voltage 24 VDC 28 VDC or less 24 VDC (10 to 28 VDC) Load current range Indicator light 5 to 40mA (24 VDC) 40mA or less 5 to 40mA Relay, PLC IC circuit, Relay, PLC 24 VDC Relay, PLC PLC: Programmable Logic Controller Refer to page 889 for the applicable auto switch list.
: 50mA 48VAC or VDC: 40mA 100VAC or VDC: 20mA IS1000E-3004 IS1000E-4002 Note 2) AC40 AR40, AW40 AWM40, AWD40 IS1000E-4003 12.5 37 62.5 32 80.5 IS1000E-4004 Max. operating current IS1000E-4006 Note 1) in the model numbers indicates a thread type.
PB19PB20 1, 2 0 0 OFF PB03 0h PB04 FFC 100 100% 0 0 100 1s PB05 500 PB06 GD2 1 (8.1.1) 7.0 0 300.0 0100.0 PB07 PG1 12 24 rad/s 1 2000 6 16 6 PB08 PG2 12 37 rad/s 1 1000 PB09 VG2 12 823 rad/s 20 50 PB10 VIC 12 33.7 ms 0.1 1000.0 PB11 VDC (RYn2)7 980 0 1000 PB12 0 PB13 NH1 1 1 PB01()1 PB010 4500 Hz 100 4500 PB14 NHQ1 1 1 0h 0 0 0 40dB 1 14 d B 2 8 dB 3 4dB PB01
IDFB4E to 15E AT 1.6 [40] IDF IDU Air Flow Capacity 2.36 [60] Model IDFB3E IDFB4E IDFB6E IDFB8E IDFB11E IDFA D Circuit breaker 5 SCFM (8 m3/h) 13 SCFM (23 m3/h) 17 SCFM (29 m3/h) 19 SCFM (32 m3/h) 23 SCFM (39 m3/h) Air flow capacity (ANR) IDFB IDFB A Conditions: Inlet air pressure: 100 psi (0.7 MPa), Inlet air temperature: 100F (37.8C), Outlet air temperature: 50F (10C), Ambient temperature
(M3, M5 type only) Use SMCs recommended grease. Grease pack part number: GR-S-010 (10 g) M3, M5, Rc port, NPT port Use the correct tightening torques listed below.
Clip Approx. 80 to 90 or b Auto switch mounting band Fig. 1-5 Fig. 1-4 a Switch holder Enlarged view of clip M2.5 set screw (Accessory) e i Auto switch r Reinforcing plates w q y u c M3 set screw 5.1 or more 0 to 5 t Reinforcing plates M3 set screw Nut M3 set screw Nut The end of the set screw is protruding.
By continuously turning the 24 VDC power ON/OFF, the fluid flows from the suction port
T-brackets T-nuts Model LC1-1-L5 (Weight: 16.0g) Model LC1-1-L3 (Weight: 15.5g) M (Weight: 10.0g) M5 M3 17.5 17.5 17.5 7.5 18 12 11 M Model 20 7.5 7.5 21 LC1-1-N3 M3 x 0.5 29 30 LC1-1-N5 M5 x 0.8 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Controller Connectors
Tightening of M3, M5, and M6 connection threads 1) M3 After tightening by hand, tighten an additional 1/4 rotation with the correct tool. 2) M5 and M6 After tightening by hand, tighten an additional 1/6 rotation with the correct tool. Overtightening can cause damage to the threads and/or air leakage due to deformation of the gasket.