D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
L With surge voltage suppressor H 100 VAC J 110 VAC K 200 VAC L 230 VAC M Conduit terminal 24 VDC With surge voltage suppressor N 100 VAC P 110 VAC Q 200 VAC R 230 VAC S Conduit 24 VDC With surge voltage suppressor T 100 VAC U 110 VAC V 200 VAC W 230 VAC Faston terminal Y 24 VDC Z Other voltages For other special options, refer to pages 20 and 21. 24 VAC 48 VAC 220 VAC 240 VAC 12 VDC Special
200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC All types equipped with surge voltage suppressor.
Thread type Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Voltage Port size 1/8 (6A) Class 3 Class 2 Class 4 Symbol 01 02 03 04 06 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Please consult with SMC regarding other voltages.
Internal wiring 1 3 5 6 01 C6 C8 VZ523MOZ-VZ3Applicable solenoid valve 100 VAC 50/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC Rated voltage Note) Withstand voltage specification of wiring unit part is equivalent to JIS C 0704 class 1.
With surge voltage suppressor N 100 VAC 8 40A N.C. R CAC408 40 40A Flange P 110 VAC F N.O. Q 200 VAC 9 50A N.C. S CAC408 50 50A Flange R 230 VAC G N.O.
8 F 24 VDC 5 G DIN terminal 24 VDC With surge voltage suppressor A B D E H J L M 4 H 100 VAC Size 2 2 1/4 N.C. 7 J 110 VAC Aluminum 4 5 N.O. 3/8 K 200 VAC 7 L 230 VAC 4 8 7 Resin (With bracket) M Conduit terminal 24 VDC With surge voltage suppressor 4 N 100 VAC 10 7 P 110 VAC A B C D E F G H J K L M N 5 Q 200 VAC Size 3 3 N.C. 8 1/4 R 230 VAC 10 (N.C. only) 6 N.O.
Grommet Flange type with surge voltage suppressor 110 VAC A B C D Direct piping type 200 VAC Flange type 230 VAC 80A 6 Flange body I type 24 VDC Flange body II type 24 VDC DIN terminal with surge voltage suppressor 100 VAC 7 8 90A B Flange type 110 VAC 100A 200 VAC 230 VAC 24 VDC Conduit terminal 100 VAC with surge voltage suppressor 110 VAC 200 VAC 230 VAC 24 VDC Conduit with surge voltage
K C37 1 25 L Stainless steel G 24 VDC DIN terminal With surge voltage suppressor Note) H 100 VAC J 110 VAC K 200 VAC L 230 VAC N 100 VAC Conduit terminal With surge voltage suppressor P 110 VAC Q 200 VAC R 230 VAC T 100 VAC Conduit With surge voltage suppressor U 110 VAC V 200 VAC W 230 VAC Z Other voltages Note) For the class H type DIN terminal, use it in combination with the connector
21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 90 to 264 VAC 21.6 to 26.4 VDC 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.
VCW 20 1 G Clip Series Lead wire length 20 30 40 300 mm 600 mm 1000 mm 1500 mm 3000 mm Nil L1 L2 L3 L4 Class 2 Class 3 Class 4 Flat head screwdriver Voltage Solenoid coil 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Electrical entry Insert a flat head screwdriver into the hook section of the clip groove.
Where the load voltage is 100 VAC. The contact life may be shortened (due to permanent energizing conditions). Where the load voltage is 110 VAC.
Note) Air flow capacity (scfm [ANR]) Applicable air compressor (kW) 50 Hz Model Power supply voltage (Frequency) Port size 60 Hz IDF1E 3.53 4.24 0.75 Single-phase 100 VAC (50 Hz) Single-phase 100/110 VAC (60 Hz) IDF2E 7.06 8.30 1.5 Rc3/8 IDF3E 11.3 13.1 2.2 IDF4E 18.4 20.1 3.7 Rc1/2 Single-phase 100/200 VAC (50 Hz) IDF6E 26.5 29.0 5.5 Single-phase 100/110 VAC, 200/220 VAC (60 Hz) IDF8E 43.1
VAC 4 DC Nil 300 mm 6 600 mm 10 1000 mm 15 1500 mm 20 2000 mm 25 2500 mm 30 3000 mm 50 5000 mm Supply valve/ Release valve w Rated voltage DC CE-compliant AC (50/60 Hz) CE-compliant 5 24 VDC V 1 100 VAC 6 12 VDC V 2 200 VAC V 6 VDC V 3 110 VAC [115 VAC] S 5 VDC V 4 220 VAC [230 VAC] R 3 VDC V x How to Order Vacuum Pressure Switch * CE-compliant: For DC only A M L ZL ZSE30A 00 e Electrical
Note 2) Fixed unit: kPa Note) Air operated, 100 VAC, and 110 VAC type are not CE-compliant. Refer to Table (2) on page 941 for part no. of lead wire with connector.
How to Order 03 ADM200 1 Thread type Operating time/Applicable compressor Nil N F Rc NPT G Nil 2 sec/min (1 time/min) /3.7 to 37 kW 4 sec/min (2 times/min) /37 to 75 kW 6 sec/min (3 times/min) /75 to 110 kW 8 sec/min (4 times/min) /220 to 370 kW 4 6 8 Port size Voltage OUT IN Symbol 04 03 100 VAC Hz 1 3 8 3 8 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Electrical entry G Body Coil voltage Lead wire length 0.6 m 5: Plug lead sub-plate 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Lead wire length 1.5 m Grommet H Function Nil Y(1) R(2) Standard type (1 W) Low wattage type (0.5 W) External pilot Seal 0 1 Metal seal Rubber seal Note 1) Note 2) Applicable to DC specifications.
for 1 minute (between lead wire and case) 1) 1000 VAC for 1 minute (between lead wire and case) Withstand voltage Ambient temperature 10 to 60C Enclosure IEC60529 standard IP67, JIS C 0920 waterproof construction Standards Conforming to CE standards 1) For connector type D-A73C and A80C, 1000 VAC for 1 minute (between lead wire and case). 2) Except solid state switch with timer D-F7NTL,