SMC Corporation of America
Elite Part Number Search
Search Results "RZQA63-250-120"

, 300, 350 84 36.5 30.5 M5 x 0.8 23.2 11.5 37.5 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 91 41.5 31.5 Rc 1/8 30.2 12.5 37.5 WA Bore size (mm) ML T U VA VB OA OB OL PA PB PW Q R S MM NN st 25 24 24 st 30 30 < st 100 48 25 < st 100 100 < st 200 200 < st 300 300 < st 350 20 25 32 9.5 9.5 11 13 15 20 5.6 5.6 6.6 12.5 18 26 30 70 78 96 30 81 72 82 98 120 120 124 54 64 78 44

Standard Strokes Bore size (mm) Standard stroke (mm) 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 12, 16 20, 25 32 to 100 Manufacture of Intermediate Strokes Spacer installation Spacers are installed in the standard stroke cylinder. 12 to 32: Available by the 1

Table 3.1-1 Weight of the product Model Weight kg Option increase HRL100-A-40 Approx.240 Option-D1:+1kg HRL200-A-40 Approx.260 Option-T2:+1kg HRL300-A-40 Approx.330 Option-T3:+18kg* HRL100-W-40 Approx.250 HRL200-W-40 Approx.250 *Applicable only to HRL300-A*-40. 3.1 Transport HRL Series 3-2 HRX-OM-X037 Chapter 3 Transport and Setting Up 3.1.2 Transportation using casters This is a heavy product

Pulse Signal Wiring Details Pulse signal output of positioning unit is differential output Positioning unit Inside of the driver NP+ 1 k NP 120 PP+ 1 k PP 120 Pulse signal output of positioning unit is open collector output Pulse signal power supply Positioning unit Inside of the driver Note) Connect the current limiting resistor R in series to correspond to the pulse signal voltage.

When the source pressure is 1700 psig (11.7 MPa), achievable delivery pressure is around 125 psig (0.86 MPa ) (HF and FC option 120 psig (0.83 MPa)). 2) 250 psig outlet pressure preset at 800 psig (5.5MPa) inlet pressure. Custom inlet/outlet pressure settings available.

v=l t P"p1 + 147 Where V = capacity of rceiver Q = compressor outpul (clm) Pa = atmosphric plsssurc P1 = compressor outsul pressure V = (600'14.7y(10O+14.7) =77lf as a minimum number, a prudent suggestion might begin with 120 ft".

250 W = 400 W = 500 300 100 5 LAT3m-20 Frequency [cpm] Frequency [cpm] Allowable thrust setting value 150 200 120 250 W = 300 LAT3m-30 4 200 150 200 150 W = 0 W = 100 W = 200 200 150 300 100 W = 0 W = 100 W = 200 3 300 100 600 50 600 50 2 0 0 0 5 10 15 20 25 30 Stroke(Positioning distance) St [mm] 0 5 10 15 20 25 30 Stroke(Positioning distance) St [mm] 1 Operating condition Model: LAT3F-m

Station n L1 L2 L3 L4 Station 20 341 328 304 296 3 69 56 32 24 6 117 104 80 72 8 149 136 112 104 10 181 168 144 136 Station 2 53 40 16 8 4 85 72 48 40 5 101 88 64 56 7 133 120 96 88 9 165 152 128 120 11 197 184 160 152 12 213 200 176 168 13 229 216 192 184 14 245 232 208 200 15 261 248 224 216 16 277 264 240 232 17 293 280 256 248 18 309 296 272 264 19 325 312 288 280 4-4-27 Series SYJ500

v=l t P"p1 + 147 Where V = capacity of rceiver Q = compressor outpul (clm) Pa = atmosphric plsssurc P1 = compressor outsul pressure V = (600'14.7y(10O+14.7) =77lf as a minimum number, a prudent suggestion might begin with 120 ft".

Speed loop P constant A 110 140 140 1 to 200 B 120 75 100 C 150 120 120 H 50 80 80 Sets the speed loop I constant. *Please perform the actuator operation after changing this parameter setting under the responsibility of the user. Speed loop I constant A 110 50 50 10 to 200 B 90 60 60 C 100 60 60 Positioning time level 2 2 2 Sets the time to generate the positioning time error alarm.

17 9 () 1.2 LEFS LEFS16 LEFS25 A B H A B [mm] 10 5 20 12 6 [mm] 500 500 500 600 700 800 600 700 800 600 700 800 [mm/s] 500 250 1000 900 630 550 500 420 330 250 230 180 [mm/s] 10 5 20 12 6 () [mm/s] 17 9 33 20 10 () LEFS32 H A B [mm] 24 16 8 [mm] 600 700 800 900 1000 800 900 1000 800 900 1000 [mm/s] 1200 930 750 610 500 500 410 340 250 200 170 [mm/s] 24 16 8 () [mm/s] 39 26 13 () 108

Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke (mm) 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and interpolation) 15 8 4 18

-107No.JXC-OMT0001CN-C 1. 1.1 LEY/LEYG LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 A B C A B C A B C A B C [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 [mm] 300 300 300 400 400 400 500 500 500 500 500 500 mm/s 500 250 125 500 250 125 500 250 125 300 150 75 [mm/s] () 15 8 4 18 9 5 24 12 6 24 12 6 [mm/s] () 22 12 6 26 13 7 34 17 9 34 17 9 1.2 LEFS LEFS16 LEFS25 A B H A B [mm] 10 5 20

Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke (mm) 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and interpolation) 15 8 4 18

Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke [mm] 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and 15 8 4 18 9 5 24 12 6 24

Z Dimensions (mm) Model A B C E H I X Y Z J K L S 250 250 250 30 30 30 VXF25B< VXF26B< VXF27B< VXF28B< 182 206 206 206 18.3 34 34 34 90 100 110 120 78.4 78.4 78.4 78.4 118 121 121 121 59.8 59.8 59.8 59.8 47 50 50 50 24 24 24 24 18.6 18.6 18.6 18.6 30 30 30 30 17 17 17 17 Grommet Grommet (with surge voltage suppressor) DIN terminal Model Q R U Q R U 27 27 27 27 R U T 64.5 64.5 64.5 64.5

IR 0.8 0.8 0.5 Set pressure (MPa) Set pressure (MPa) 0.7 0.7 Set point VEX 0.6 0.6 0.5 0.5 0.0 AMR 0.4 0.4 0.3 0.3 0.5 0.2 ITV 0.2 0.1 0.1 1.0 0.0 0.0 IC 0 50 100 150 200 250 300 350 0.4 0.6 0.8 1 1.2 0 50 100 150 200 250 300 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Supply pressure (MPa) VBA VE Series ITV205 VY1 G Repeatability Linearity Hysteresis 1.0 0.9 0.5 1.0 PPA Out 0.8 Output

(same side) n = 2, 4, 6, 8 n = 4, 8,1 2, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 15 100 1 pc. 100 110 120 1 or 2 pcs. 15 120 120 130 140 D-F5W, D-J59W D-F5BA D-F5F D-F5NT (different sides/same side) (n 4) 2 140 + 55 (n 4) 2 (n 2) 2 (n 4) 2 (n 4) 2 15 + 55 120 + 55 120 + 55 130 + 55 "n" pcs.

0 20 40 60 80 100 120 10 20 30 40 50 60 70 0 Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) MHL2-20D MHL2-25D MHL2-25D 2 1 2 1 MHL2-20D 200 200 120 120 Gripping force (N) Gripping force (N) Gripping force (N) Gripping force (N) 160 160 Pressure 0.6 MPa Pressure 0.6 MPa 100 100 Pressure 0.6 MPa Pressure 0.6 MPa 0.5 MPa 0.5 MPa 120 120 80 80 0.5 MPa

MP 0.2 MPa 0.2 MPa 20 20 0 20 40 60 80 100 120 140 0 40 80 120 160 200 0 40 80 120 160 20 40 60 80 100 120 0 Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) MHL2-40D1 2 MHL2-32D1 2 MHL2-40D MHL2-32D Pressure 0.6 MP 0.6 MPa Pressure 0.6 MPa 500 500 Pressure 0.6 MP 0.6 MPa Pressure 0.6 MPa 300 300 Pressure 0.6 MP 0.6 MPa Pressure 0.6 MPa Pressure 0.6