Bore size Series CS1 Pressure 0.5 MPa Load factor 50% Stroke 300 mm 125 140 160 180 200 250 300 Average speed (mm/s) Series VK 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ VFS5100-06 VF 0 VFR It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being
400 500 600 700 800 900 1000 Flow rate (slpm, N2) 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Flow rate (slpm, N2) AK1200HF 150 psig (1.0 MPa) 50 psig (0.34 MPa) Inlet pressure: 100 psig (0.69 MPa) AK1200FC Inlet pressure: 150 psig (1.0 MPa) 3/4 inch connections ) 100 0.69 75 0.52 0.62 90 0.55 80 60 0.41 Delivery pressure (MPa) Delivery pressure (MPa) Delivery pressure (psig
C4: 4 (SMC) C6: 6 (SMC) C8: 8 (SMC) N3: 5/32" (SMC) N7: 1/4" (SMC) N9: 5/16" (SMC) L: DIN Rail Overall Length n: Stations L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L1 L2 L3 L4 L5 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 335.5 360.5 373 385.5 410.5 423 435.5 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 325 350 362.5 375 400 412.5 425 120.2 136.2
For response time, refer to the graph below. 400 350 Response time (ms) 300 250 Step Motor (Servo/24 VDC) 200 150 100 50 0 1 2 3 4 5 6 7 8 9 10 11 12 This graph shows delay times between gateway unit and controllers. Fieldbus network delay time is not included.
260.5 240 250 260.5 251 262.5 273 262 275 285.5 273 287.5 298 284 300 310.5 How to Order
300 Flow rate /min(ANR) Flow rate /min(ANR) Condition: Inlet pressure 0.7MPa Condition: Inlet pressure 0.5MPa ARM11AA1-312 (One-touch fittings: IN 10, OUT 6) ARM11AA1-312-1 (One-touch fittings: IN 10, OUT 6) 0.6 0.7 0.30 0.35 Outlet pressure MPa Outlet pressure MPa 0.25 0.5 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 250 300 0 50 100 150 200 Flow rate /min(ANR) Flow rate
Weight[kg] Series LEKFS25 Stroke [mm] 50 100 150 200 250 300 350 400 450 500 600 700 800 S2 2.0 2.1 2.3 2.4 2.6 2.7 2.8 2.9 3.1 3.2 3.5 3.7 4.0 Motor type T6 2.1 2.2 2.4 2.5 2.7 2.8 2.9 3.0 3.2 3.3 3.6 3.8 4.1 Additional weight with lock [kg] 0.2 Series LEKFS32 Stroke [mm] 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 S3 3.4 3.6 3.8 4.0 4.3 4.5 4.7 4.9 5.1 5.3 5.8 6.2 6.6 7.1
Applicable stroke table Size Stroke [mm] 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 25 32 40 25 - .
For Air 1.0 Downstream pressure of valve (P2) [MPa] Upstream pressure of valve P1z1.0 MPa 0.8 Subsonic 0.9 0.6 Critical pressure 0.8 0.7 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 3/64 (1.2) 50 100 150 3/32 (2.4) 100 200 300 400 1/8 (3.2) 300 200 100 400 500 600 700 5/32 (4) 200 1, 000 800 400 600 7/32 (5.6) Series VXN2 250 500 7/32 (5.6) Series VXN3 500 1, 000 1, 500 2, 000 Flow rate Q [L/min
S 6 50, 100, 150, 200 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com "n" pcs. n 8 50, 100, 150, 200, 250, 300 12 50, 100, 150, 200, 250, 300, 350, 400 Auto switch type Nil Without auto switch Adjuster option Nil Rubber stopper B Shock absorber Metal stopper One
76.1 Max. 10 66.1 77 Pg7 65.2 [72.2] Approx. 300 (Lead wire length) 41.1 M8 x 1 58.6 68.1 38.7 Approx. 300 (Lead wire length) 79.4 54.1 [61.1] 86.9 Applicable cable O.D. 3.5 to 7 Refer to page 4-4-61 for dimensions with connector cable.
Copper extension nozzle/KNL (mm) Model Nozzle size D Outside diameter L1 Weight (g) KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 1.5 2 2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 43 43 61 61 94 94 84 84 117 117 183 183 O.D.
Heavy load Standard load Medium load Light load [mm/s] Switch and Speed Note 1) Switch and Acceleration Note 2) [m/s2] Nominal size Low speed Medium speed Standard speed 16 25 E-MY2BH1612 Stroke 1 2 3 4 5 6 7 8 9 10 10 20 30 40 50 75 100 300 500 1000 50 75 100 125 150 200 250 300 500 1000 100 200 300 400 500 600 700 800 900 1000 1 2 3 4 5 6 7 8 9 10 0.25 0.49 0.74 0.98 1.23 1.47 1.72 1.96
This product supports level 03H. 00H: 31.25, 62.5, 125, 250, 500 (sec), 2 to 64 (msec) (2 msec increment) 01H: 31.25, 62.5, 125, 250, 500 (sec), 1 to 64 (msec) (1 msec increment) 02H: 31.25, 62.5, 125, 250, 500 (sec), 1 to 64 (msec) (0.5 msec increment) 03H: 31.25, 62.5, 125, 250, 500, 750 (sec), 1 to 64 (msec) (0.5 msec increment) 18H Binary Data Minimum Value of Communication Cycle 4 bytes
Initial value Recommended value Number of command input pulses per revolution *3 PA05 0 0 Electronic gear numerator *3 PA06 1 32768 Electronic gear denominator *3 PA07 1 250 150 75 300 200 100 375 250 125 Regenerative option PA02 0 0(Non) / 0002(LEC-MR-RB-032) Rotation direction selection PA14 0 1(+Counter motors side) Adaptive tuning mode PB01 0 0 Load to motor inertia moment ratio PB06
150 500 250 250 824 846 (mm) A 531 570 494 527 B 444 479.8 444 479.8 C 3/8 1/2 3/8 1/2 D Note) 519 543 Booster regulator model The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Supply pressure (MPa) Series ITV205 Linearity Hysteresis Repeatability 1.0 0.9 1.0 0.5 Output deviation factor (%F.S.)
Cylinder Speed Chart Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Stroke 1000 mm Average speed (mm/s) System 50 63 80 100 125 140 160 180 200 250 300 1000 Perpendicular, upward actuation 900 800 700 600 500 400 300 200 100 VK Horizontal actuation A VZ VF 0 1000 VFR 900 800 700 600 500 400 300 200 100 0 VP4 Courtesy of Steven
Applicable Controller Power Supply Voltage 100VAC Specification Series LJ1H10 Series LJ1H20 LJ1H1021H-K (8mm lead) LJ1H2021F-K (5mm lead) 250 400 225 350 12kg 6kg 200 300 175 250 Speed (mm/s) Speed (mm/s) 150 8kg 13kg 125 200 10kg 100 150 14kg 75 100 15kg 50 50 25 0 100 200 Stroke (mm) 300 400 0 100 200 300 400 500 600 Stroke (mm) When an actuator is operated under conditions that exceed
R1 R2 < >: AC 5 3 Equation L1=16n+10 L2=16n+20 n: Station (Max. 20 stations) Dimensions 2 42 52 75 85.5 L n 3 58 68 87.5 98 20 330 340 362.5 373 15 250 260 287.5 298 16 266 276 300 310.5 17 282 292 312.5 323 18 298 308 337.5 348 19 314 324 350 360.5 12 202 212 237.5 248 13 218 228 250 260.5 14 234 244 275 285.5 7 122 132 162.5 173 8 138 148 175 185.5 9 154 164 187.5 198 10 170 180 200 210.5