SMC Corporation of America
Elite Part Number Search
Search Results "PSE543A-M3"

/min 0.46 m3/min 0.80 m3/min (Max.) 0.66 m3/min 0.46 m3/min 0.80 m3/min (Max.)

Example) AM30-N03BD-6RZ-D q e r t y w Symbol Description w Body size 20 30 40 50 60 AFF Nominal filtration rating: 1 m V V V V V Water droplet removal ratio: 99% AM Nominal filtration rating: 0.1 m V V V V V Oil mist concentration on the outlet side: 1 mg/m3 q Filter type AMD Nominal filtration rating: 0.01 m V V V V V Oil mist concentration on the outlet side: 0.1 mg/m3 + e Thread type

Body through hole MI W S CEP1 CE1 Max. tightening torque (Nm) Model MIW8 MIS8 MIW12 MIS12 MIW20 MIS20 MIW25 MIS25 MIW32 MIS32 Bolt CE2 M2.5 x 0.45 0.5 ML2B M3 x 0.5 0.88 C J G5-S M5 x 0.8 4.3 CV M6 x 1 7.3 MVGQ M8 x 1.25 17.5 Max. tightening torque (Nm) Bolt Model MIW8 MIS8 MIW12 MIS12 MIW20 MIS20 MIW25 MIS25 MIW32 MIS32 CC M3 x 0.5 0.88 Caution RB M3 x 0.5 0.88 1.

Max. load weight CX 2 = M/Mmax Review M1, M2, M3. Mmax is the allowable moment. 2. Static moment CY 3 = Me/Memax Review Me1, Me3. Memax is the allowable moment. 3.

Model Specifications AN101-01 AN110-01 AN120-M3 AN120-M5 R R M3 M5 1 8 1 8 Port size (1) Noise reduction (dB (A)) Fluid Max. operating pressure (2) 13 18 16 21 Compressed air 1.0 MPa 5 to 150C (3) Ambient and fluid temperature Effective area (mm2) Weight (g) 20 35 1 5 9.5 20 1 3.3 22.5 38 9 17 11 A B 13 6 8 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370

(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without unit switching function.) Refer to the specifications of display unit for the flow rate value per pulse.

Description ZS-28-A Note D Power supply/Output connection cable Mounting screw (M3 x 8L) (accessory) Bracket ZS-28-B With M3 x 5L (2 pcs.) Sensor connector ZS-28-C 1 pc. Panel mount adapter Panel mount adapter ZS-27-C With M3 x 8L (2 pcs.) ZS-27-D With M3 x 8L (2 pcs.)

(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without unit switching function.) Refer to the specifications of display unit for the flow rate value per pulse.

(Example) For M3: L1 = 6 Applicable shaft types: S, Y L2 + (3 x P) L1 + ( 3 x P) Q1 = M Y axis S axis (mm) (mm) Q1 Q2 L1 = Shaft type Shaft type S Y S Y Size Size L2 + (3 x P) L2 = 50 50 M3, M4, M5, M6 M3, M4, M5 M3, M4, M5 L2= 63 63 M4, M5, M6 M4, M5, M6 M4, M5, M6 Q2 = M 80 80 M4, M5, M6, M8 M4, M5, M6 Q2 = M M4, M5, M6 100 100 M5, M6, M8, M10 M5, M6, M8 M5, M6, M8 Symbol: A33 Machine

(Fixed SI unit [(l/min, or l, m3 or m3 x 103)] will be set for switch type without the unit switching function.) Note 3) The high flow rate type is CE marked; however, the linearity with applied noise is 5% F.S. or less. Note 4) Switch output and accumulated pulse output selections are made using the button controls.

It is calculated using the following formula. 1 x 105 Kv = Q (8) P 1000 Kv : Flow coefficient [m3/h] Q : Flow rate [m3/h] DP : Pressure difference [Pa] r : Density of fluid [kg/m3] (3) Formula of flow rate It is described by practical units. Also, the flow rate characteristics are shown in Graph (2).

x 0.5 3.5 M3 x 0.5 M3 x 0.5 16 50.5 10.8 24.4 9.4 25 9.5 2H9 2 M3 x 0.5 4.8 20 22.5 2H9 2 11 2H9 2 M3 x 0.5 3.5 M4 x 0.7 M3 x 0.5 18 56 13.4 26.2 11.3 28 10 2H9 2 M3 x 0.5 5.3 21 24.5 2H9 2 11.5 2H9 2 M3 x 0.5 3.5 M5 x 0.8 M3 x 0.5 20.5 60 15.2 31 11.8 30.5 12 2H9 2 M3 x 0.5 5.3 25 27 2H9 2 13.5 2H9 2 M4 x 0.7 4.5 M6 x 1 M5 x 0.8 23 73.5 15.4 37.4 14.9 34.5 14 3H9 3 M4 x 0.7 6.5 29 32.5

Note) Order is accepted in 10 units. 3 Compact Direct Operated 3 Port Solenoid Valve Series S070 Dimensions Base mounted with screws S070B-G-M3 Grommet type 16 3 7 12 18 2-3.4 Mounting hole 5 150 (lead wire AWG#26) 22 6 20.5 19 3 2 1 9.5 6.5 5.5 4.5 12.3 10 10 25 M3 0.5 3 (EXH) port M3 0.5 1 (SUP) port M3 0.5 2 (OUT) port S070B-C-M3 Plug lead type 0.1 W with power saving circuit 150 (lead

steel/NBR POM/Stainless steel NBR NBR ASV Note) M3 type is made of stainless steel.

Body fixed A L Maintenance L (mm) A (mm) 20 24 30 31 Model Bolt Warning LEF;16 LEF;25 LEF;32 LEFS40 3.5 4.5 5.5 6.6 M3 M4 M5 M6 Maintenance frequency Perform maintenance according to the table below.

plated (with spring washer) Round head combination screw M3 x 47 Matt nickel plated (with spring washer) Gasket SYJ700-5-3 Round head combination screw M3 x 10, Matt nickel plated (with spring washer) 7 Round head combination screw M3 x 10, Matt nickel plated (with spring washer) Adapter plate SYJ700-3-3 A B A B 7 Adapter plate SYJ700-3-2 O-ring SYJ300-9-5 Manifold Gasket DXT199-21-11 15

Note: 1g = 0.0353oz Options Body options/End boss type Single acting type, normally closed Symbol Piping port position Applicable model Double acting Type of piping port MHZA2-6/MHZAJ2-6 M3 x 0.5 M3 x 0.5 With 4 One-touch fitting With 4 hose nipple M3 x 0.5 Single acting Standard Side ported Nil E K H M Axial port 2 Series MHZA2-6/MHZAJ2-6 Parallel Type/Compact Series Construction/Standard

Remove the thin head screws (TP-M3 x 5, 8 pcs.) fixing the pulley cover using a hexagon wrench. Use a normal hexagon wrench. TP-M3 x 5 TP-M3 x 5 2. Pull out the pulley cover in the direction of the arrow. Pulley cover Motor mounting process 1.

IDFB Corrected air flow capacity = 31 m3/h (0.83 x 0.83 x 0.92) = 48.9 m3/h Obtain the corrected air flow capacity from the following formula. Corrected air flow capacity = Air consumption (Correction factor A x B x C) IDH 3 ID Select the model. According to the corrected air flow capacity of 48.9 m3/h, the IDFA8E will be selected when the required output air pressure dew point is 3C.

screw) 31 0.5 45 45 3 3 5.3 5.3 250.2 250.2 32 16 2 x M3 x 0.5 through 6.5 counterbore depth 5 (Same on the opposite side) 3.4 through 3 3 45 5.5 45 M2.5 x 0.45 x 6 L (Hexagon socket head cap screw) M3 x 0.5 x 12.5 L (Hexagon bolt) and M3 x 0.5 (Hexagon nut) 2 x M3 x 0.5 through Steel ball Plug 2 x M3 x 0.5 through 2.75 (11) (10+ST) 250.2 4 Part no.