MPa) Outlet air set temperature Outlet air set temperature 68F (20C) 77F (25C) Air flow Air flow 10.6 scfm (300 L/min [ANR]) 17.7 scfm (500 L/min [ANR]) E E IDH4 or IDH6 are selected from Data .

Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter rate of change of 10% or less.

12.3 810 12.3 32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C

Characteristics 65 or less Cable length (L) Conductor resistance /km, 20C Voltage limit V, 1 min, AC 1.5 m 3 m 5 m AXT100-DS25-015 ~ = 10 Cable 25 core x 24AWG AXT100-DS25-030 1000 AXT100-DS25-050 L Insulation resistance Mkm, 20C For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. 5 or more 16 44 Note) The min. bending radius of D-sub cable

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

COM COM Conductor resistance /km, 20C 65 or less Note) Mounting valve has no polarity. It can also be used as a negative common. Voltage limit V , 1 min, AC 1000 SpecialWiring Specifications (Option) [-K] Insulation resistance M/km, 20C 5 or more Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids.

. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) The 20A, 20B, and 20C series have been added to the product lineup.

Flow rate conversion NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3kPa Standard state: 20C, 101.3kPa, 65%RH (ANR) Switchable between these states.

Note 2) Flow rate display can be switched between the basic condition of 0C, 101.3 kPa and the standard condition (ANR) of 20C, 101.3 kPa, and 65% RH. Note 3) Without lead wire. Note 4) Accumulated flow rate is reset when the power supply turns OFF. Note 5) Switch output and accumulated pulse output can be selected during initial setting.

Flow at 20C, atmospheric pressure, and 65% of the relative humidity The maximum flow capacity varies depending on the inlet pressure.

(Coil temperature : 20C, at rated voltage and without surge voltage suppressor) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

Item Property Conductor resistance /km, 20C 65 or less Voltage limit V, 1 minute, AC 1000 Circular connector cable assembly Insulation resistance M/km, 20C Note) When using the negative COM specification, use valves for negative COM. 5 or more Assembly part no.

Lead wire length 0 1 2 0.6 m 1.5 m 3.0 m Electrical characteristics Item Characteristic Sheath Colour: Urban white Conductor resistance /km, 20C 65 or less Withstand pressure V, 1 minute, AC 1000 Polarity Terminal no. Lead wire colour Dot marking Insulation resistance M/km, 20C 5 or more 1 () (+) Black None SOL. A 14 () (+) Yellow Black Station 1 SOL.

Insulation resistance M/km, 20C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5 or more Note) The minimum bending radius of the D-sub connector cables is 20 mm.

AK ASS ASR ASF Flow Rate and Effective Area JIS Symbol ASD230FM ASD330FM ASD430FM Model 6, 8 8, 10 6 Metric size 4, 6 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 1/4", 5/16" 3/8" 3/16", 1/4" Inch size Flow rate (l/min(ANR)) Controlled flow (Free flow) 7 12 38 0.1 0.6 0.2 Effective area (mm 2) Note) Flow rate values are measured at 0.5 MPa and 20C.

[Example of setting] Circulating fluid SP: 20C (1) High Temp. CH1 circulating fluid temperature rise (AL10): 22C (2) Low Temp.

[Example of setting] Circulating fluid SP: 20C (1) High Temp. CH1 circulating fluid temperature rise (AL10): 22C (2) Low Temp.

Note) Supply pressure: 0.5MPa, Temperature: 20C. In-line style How to Order 1F 12 K 400 AS JIS Symbol Option Body size K N None Hexagonal lock nut Electroless nickel plated 100 200 205 300 400 M5 1/8 1/4 3/8 1/2 Indicate symbols in alphabetical order if two options or more desired. Applicable tube O.D.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Compact design with large flow Sonic conductance: C [dm3/(sbar)] Body width [mm] 10 15 18 1.1 2.8 4.5 Response time 10 ms (Representative value) (SX3000 double, 0.5 MPa, 20C) High reliability and long service life exceeding 50 million cycles or more (