Do not drop, bump, or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 5. Do not allow short circuiting of loads.
Body Ported Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB, CA2 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQZ1121-C6 SJ SY 800 700 600 500 400 300
Tightening torque should be set 0.10 to 0.20 N.m. 11 Series C55 Auto Switch Specifications Auto Switch Common Specifications Reed switch Type Leakage current Solid state switch 3-wire: 100 A or less 2-wire: 0.8 mA or less None Operating time 1.2 ms 1 ms or less 300 m/s2 1000 m/s2 Impact resistance 50 M or more at 500 VDC Mega (between lead wire and case) Insulation resistance Withstand voltage
S1 S2 Effective area ratio 2.3 : 1 Pressure loss: Large K M 3 Without nozzle 3 H Pressure Loss of Air Gun Only Effective area (mm2) Upstream side S1: 15 Nozzle side S2: 6.4 D S1 : S2 = 2.3 : 1 Effective area ratio Nozzle size (mm) Number of nozzles Supply pressure Regulator pressure Outlet pressure Pressure loss 3 MS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco,
Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized) 980 m/s2 in X, Y, Z directions, 3 times each (De-energized) Impact resistance Temperature characteristics (Based on 25C) 2% F .S. or less based on the analog output value at 25C from a range of 0 to 50C Port size M5 x 0.8 Material Body: Stainless steel Grade 303,
ZP3EA-S2 [Weight: 7.6 g] 24 47 15 29 4 20 36 Applicable pad part no. ZP3E-63UM ZP3E-80UM ZP3E-100UM ZP3E-125UM ZP3E-63BM ZP3E-80BM ZP3E-100BM ZP3E-125BM Applicable pad part no.
VAC for 1 minute between external terminals and FE Insulation resistance 500 VDC, 10 M or more between external terminals and FE 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
(Example) Mass of transferred object: 300 kg, Transfer speed: 20 m/min Friction coefficient: = 0.1 Mass of transferred object m [kg] Friction coefficient RS2H50-30 The graphs indicate the values at normal temperature. (20 to 25C) = 0.1 = 0.2 500 500 Mass of transferred object m [kg] Mass of transferred object m [kg] 50 Operating range Upper limit 400 400 Upper limit 50 Operating range
Pressure 0.5 MPa Load factor 50% Stroke 500 mm VZS Average speed (mm/s) Series VFS VS4 40 50 63 80 100 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VQ7 VZ514--02 (Piping: 6 x 1 m) EVS VFN AS3301F-02-06/AN200-2 Speed controller/Silencer 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ514--02 (Piping: 8 x 1 m) AS3301F
Pressure 0.5 MPa Load factor 50% Stroke 500 mm VZS Average speed (mm/s) Series VFS VS4 40 50 63 80 100 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VQ7 VZ514--02 (Piping: 6 x 1 m) EVS VFN AS3301F-02-06/AN200-2 Speed controller/Silencer 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ514--02 (Piping: 8 x 1 m) AS3301F
oscillator Oscillator Optical system CH1 Oscillator CH1 CH2 Cooling capacity [kW] Total 5, 9.5 Temperature stability [C] 0.1 0.5 Set temperature range [C] 15 to 25 CH1+0 to 15 Footprint reduced by 21% Space saving Dual thermo-chiller 1 unit Thermo-chiller 2 units Optical system Optical system Oscillator Oscillator HRLE090 HRS012 HRS090 + Reduced by 0.13 m2 + 0.43 m2 0.37 m2 0.19 m2 965 mm 970 mm 500
valve Max. operating frequency (Hz) 5 Symbol 3 position 3 Non-locking push type Manual override Series 10-SV1000/2000/3000/4000 Push-turn locking slotted type Internal pilot Main/Pilot valve common exhaust Pilot exhaust method 2 position single External pilot Pilot valve individual exhaust (A)4 2(B) Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance (m/s2
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2CN Communication cable PC PC is prepared by customer) Refer to 9.
100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2CN Communication cable PC PC is prepared by customer) Refer to 9.CN2TB/PC Power supply connector for usage.
1 station 9 g Note) There was no malfunction confirmed when tested under the following conditions: From 10 to 500 to 10 Hz and whichever of the following is smaller: 1.5 mm amplitude or 98 m/s2 acceleration in X, Y, Z direction for 2 hours each.
VDC) Indicator light Temperature characteristics Enclosure Data Operating temperature range Operating humidity range Withstand voltage Insulation resistance Vibration resistance Impact resistance Environmental resistance 10 to 150 Hz, 1.5 mm or 20 m/s2 amplitude in X, Y, Z directions for 2 hours each 100 m/s2 in X, Y, Z directions 3 times each Compliant with CE Marking and UL (CSA) standards
of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized) Insulation resistance Vibration resistance 100 m/s2 in X, Y, Z directions, 3 times each (De-energized) 2% F.S.