900, 1000 1800, 2000 1 2 Work load [kg] note2) Horizontal Note2)Speed [mm/s] 5 to 2000 5 to 2000 Actuator specification 3,000 Max.acceleration/deceleration [mm/s2] 0.08 Positioning repeeatability [mm] 0.1 or less Lost motion[mm] note3) 48 48 Equivalent lead [mm] 50 / 20 Impact/Vibration resistanc [m/s2] note4) Actuation type Belt Guide type Linear Guide 5 to 40 Operating temperature range
Cable length (L) + B A 300 mm V100-49-1-1 VS V100-49-1-2 500 mm 1000 mm 2000 mm 5000 mm Interface V100-49-1-3 V100-49-1-4 V100-49-1-7 VFN Pilot valve (SY114) Adapter plate 22 33.9 14 4-4-61
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com New Concept Connector Type Manifold 1-2-1 2 New Concept Connector Type Manifold Series SV1000/2000/3000/4000 Series SV1000/2000/3000/4000 Series SV1000/2000/3000/4000 Product is CE compliant with standard part number.
Ex. 1) Lead wire length of 2000 mm SYJ3120-5LOZ-M3 SY100-68-A-20 Ex. 2) Lead wire length of 300 mm (standard) SYJ3120-5LPZ-M3 3 5 7 Electrical entry W1: Cable length 300 mm W2: Cable length 500 mm W3: Cable length 1000 mm W4: Cable length 2000 mm W7: Cable length 5000 mm SYJ Symbol for connector assembly with cover Ex. 1) Cable length: 300 mm SYJ3120-5W1ZE-M3 Symbol for electrical entry
Series VQ1000-2000 Base Mounted Plug-in Unit. Specifications. VQ1000-2000 F Kit (D-sub connector) . P VQ1000-2000 P Kit (Flat ribbon cable connector) . VQ1000-2000 J Kit (Flat ribbon cable connector) . VQ1000-2000 G Kit (Flat ribbon cable connector with terminal block) . VQ1000-2000 T Kit (Terminal block box kit) . VQ1000-2000 L Kit (Lead wire cable) .
Without lead wire 300 600 1 2 3 Blue (2) Red (2) Gray (2) For 100 VAC 1000 1500 2000 2500 3000 For 200 VAC Groove Pin Another VAC Cover DC indicator Lever 4 Red: +, Black: For DC How to Order Include the connector assembly part number together with the part number for the plug connector's solenoid valve without connector. (Example) 2000 mm lead wire length. VF3230-5M0-023 pcs.
MY1CW MY1MW 200 200 (kg) (kg) 190 190 (2100) (2100) (2100) (2100) 180 180 170 170 160 160 m 150 150 140 140 (2400) (2400) (2400) (2400) 130 130 L (1800) (1800) (1800) (1800) 120 120 Mass (m) Mass (m) 110 110 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) 90 90 m L (1500) (1500) (1500) (1500) MY1CW63 MY1CW63 MY1MW50 MY1MW50 80 80 m (1600) (1600) (1600) (1600) 70 70 MY1CW50 MY1CW50 MY1MW40
Note) Except SI Unit Manifold Solenoid Valves Manifold Solenoid Valves Series SY3000/5000/7000 Series SV1000/2000/3000 Series S0700 Series VQC1000/2000/4000/5000 IP67 IP40 IP67 IP67 Note) The SY3000/5000/7000, S0700, and VQC1000/2000/4000/5000 are not UL-compatible.
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz. Test was performed in both an axial direction and a perpendicular direction to the lead screw. (Test was performed with the actuator in the initial state.)
The spacing of the side support must be no more than the values shown in the graphs at right. 200 200 190 190 (2100) (2100) (2100) 180 180 170 170 160 160 m 150 150 140 140 (2400) (2400) (2400) (2400) (2400) 130 130 l (1800) (1800) (1800) 120 120 Weight m (kg) Weight m (kg) 110 110 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) 90 90 (1500) (1500) (1500) MY1CW63 MY1CW63 m 80 80
Flow Characteristics Air pressure 0.7 MPa (Example) To get pressure drop at 0.3 MPa of air pressure, 2000 l/min (ANR) of air flow, and model HAA22, use P = 0.0007 MPa from the table and convert P1 to 0.3 MPa.
PA06 1 262144 (Position control mode) 2000 1200 600 2400 1600 800 3000 2000 1000 Electronic gear denominator *3.
SJ2000-OMM0001-B SJ1000/2000/3000 Series Precautions for 4 Port Solenoid Valve 2 Be sure to read before handling. Refer to main text for detailed precautions on every series. 4.
Series NVFR2000 Manifold valve D-Subconnector for 2000 Series Plug-In type -With D sub connector Orientation of D-Sub connector for 2000 Series manifold is parallel with mounting surface. For other manifold sizes the connector receptacle is perpendicular to the mounting surface.
A to B C to D 500 L 5 to 500 -25 to 525 L/min 1000 L 10 to 1000 -50 to 1050 2000 L 20 to 2000 -100 to 2100 PF2MC7 40 to 4000 -200 to 4200 500 L 0.17 to 17.66 -0.90 to 18.50 cfm 1000 L 0.35 to 35.31 -1.80 to 37.10 2000 L 0.70 to 70.63 -3.50 to 74.20 The flow ranges and relationship between the fluid and PD are shown in the figures below.
A to B C to D 500 L 5 to 500 -25 to 525 L/min 1000 L 10 to 1000 -50 to 1050 2000 L 20 to 2000 -100 to 2100 PFMC7 40 to 4000 -200 to 4200 500 L 0.17 to 17.66 -0.90 to 18.50 cfm 1000 L 0.35 to 35.31 -1.80 to 37.10 2000 L 0.70 to 70.63 -3.50 to 74.20 The flow ranges and relationship between the fluid and PD are shown in the figures below.
Since these products are components whose end usage is obtained after installation in other equipment, the customer should confirm conformity to EMC directives for the finished product. 12 No.VQC1000V-OMM0002-B VQC1000/2000 series Specific Product Precautions 5 Be sure to read this before handling EX600 Precautions 4.
PA06 1 262144 (Position control mode) 2400 1600 800 3000 2000 1000 2700 4200 Electronic gear denominator *3.
to 500 3 300 to 2000 300 to 400 5 300 to 2000 300 to 400 10 200 to 2000 200 to 300 15 200 to 2000 200 to 300 20 150 to 2000 150 to 250 30 50 to 2000 50 to 200 60 50 to 2000 50 to 150 (Note) After installation, verify the effects of static neutralization.
connector S L N Option Option Monitor output Bracket Thread type 0 None (for preset input) Analog output 1 to 5V DC Switch output/NPN output Switch output/PNP output Analog output 4 to 20mA Without bracket Flat bracket L-bracket B Port size Rc(PT) NPT NPTF G(PF) 1 2 N T 1/4 (2000, 3000) 3/8 (2000, 3000) 1/2 (3000) 2 3 4 C 3 Option 4 F 1.12-1 Option Option Series ITV2000