(mm) Without auto switch With auto switch Bore size (mm) Stroke range (mm) C Th9 W D E H J K1 K2 L M N O P Q Z A B A B 54 40 5 to 50 40 0 0.052 13 64 50 16 52 M8 x 1.25 5 14 14 7 40 5.5 9 depth 7 1/8 14 57 15 28 64 50 75, 100 56.5 40.5 10 to 50 0 0.062 50 15 66.5 50.5 20 64 M10 x 1.5 7 18 17 8 50 6.6 11 depth 8 1/4 14 71 19 35 66.5 50.5 75, 100 58 42 10 to 50 63 0 0.062 15 68 52 20 77 M10
42 47 58 58 64 45 45 50 A1 + 2 (Stroke) Switches in the above figure are the case for the reed switches D-A73 type and D-A80 type.
Basic Style Without auto switch With auto switch Bore size (mm) Stroke range (mm) A B A B H I J K1 K2 L M N O P Q S Th9 U Z C D E 54 40 5 to 50 0 0.052 40 64 50 28 Rc 1/8 69 5 14 14 7 40 5.5 14 66 35 14 13 16 52 M8 x 1.25 9 depth 7 64 50 75,100 40.5 56.5 10 to 50 0 0.062 50 66.5 50.5 35 Rc 1/4 86 7 18 17 8 50 6.6 14 80 41 19 15 20 64 M10 x 1.5 11 depth 8 66.5 50.5 75,100 58 42 10 to 50 0
30 1/32 1/32 3/64 1/16 1/32 3/64 3/64 1/16 .022 .022 .055 .075 .020 .048 .048 .075 MODEL EL53 3 Way Normally Closed Piped Exhaust ** EL53GG8XCM EL53GH8XCM EL53HH8XCM EL53JJ8XCM 120 120 60 30 120 120 60 30 1/32 1/32 3/64 1/16 1/32 3/64 3/64 1/16 .055 .022 .055 .075 .048 .048 .048 .075 Series ELL50 Explosion Proof Valve Numbers MAXIMUM OPERATING PRESSURE DIFFERENTIAL ORIFICE SIZE CV FACTOR
30 1/32 1/32 3/64 1/16 1/32 3/64 3/64 1/16 .022 .022 .055 .075 .020 .048 .048 .075 MODEL EL53 3 Way Normally Closed Piped Exhaust ** EL53GG8XCM EL53GH8XCM EL53HH8XCM EL53JJ8XCM 120 120 60 30 120 120 60 30 1/32 1/32 3/64 1/16 1/32 3/64 3/64 1/16 .055 .022 .055 .075 .048 .048 .048 .075 Series ELL50 Explosion Proof Valve Numbers MAXIMUM OPERATING PRESSURE DIFFERENTIAL ORIFICE SIZE CV FACTOR
www.poweraire.com sales@poweraire.com 1/16 NPT Male Thread to Tube Distributed by Power Aire, Inc. 1/16 Male Pipe Thread to Tube 5 16 Hex Typ. 61/ 64 43 64 43 64 43 64 49/64 49/64 53/64 29 64 21 64Typ. Typ. 32 1/16 B2 1/2 1/16 B2 1/16 B4 1/16 B6 1/16 B3 1/16 B1 1/16 B5 Elbows: 1/16 NPT Male to Tube 1 2 15 32 3 8 3 8 17 32 3 8 19 32 17 32 19 32 17 32 Typ.
With Rod Boot l Bore size (mm) e d f h ZZ Stroke range (mm) 40 50 63 80 100 20 to 500 56 43 11.2 59 1/4 stroke 154 20 to 600 64 52 11.2 66 1/4 stroke 167 20 to 600 64 52 11.2 66 1/4 stroke 178 20 to 750 76 65 12.5 80 1/4 stroke 213 Dimensions of the mounting brackets are the same as those of the standard double acting single rod type.
61.5 59 64 58.5 56 73 68.5 69 72 68.5 66 71 65.5 63 71 74.5 61.5 59 64 58.5 56 Note 1) Adjust the auto switch after confirming the operating conditions in the actual setting.
Foot/CQ2L Foot (mm) Bore (mm) Y A L LH LT LZ B LG LS LY X LD LX L1 69.7 45.5 38.5 29.5 57 11.2 17 30 3.2 71 5.8 4 57 6.6 32 79.2 55 38.5 39 64 11.2 17 33 3.2 78 7 4 64 6.6 40 81.7 55.5 43.5 32.5 79 14.7 18 39 3.2 95 8 5 78 9 50 Refer to p.2.3-18 for rod end nut and optional bracket.
60 9 M10 x 1.5 Rc 1/4 64 89.5 35 19 For rod nut and accessory bracket, refer to page 10-12-20.
M22 x 1.5 18 +0.5 +0.3 +0.070 0 M26 x 1.5 +0.084 0 0.3 0.5 64 72 M26 x 1.5 22 +0.5 +0.3 +0.084 0 Knuckle pin and retaining ring are included.
Basic Style Without auto switch With auto switch Bore size (mm) Stroke range (mm) A B A B E D C N M L K2 Z K1 Th9 U J S H I O P Q 40 54 5 to 50 0 0.052 40 64 50 28 Rc 1/8 52 16 13 5.5 40 7 14 14 14 35 5 66 69 14 M8 x 1.25 9 depth 7 50 64 75,100 40.5 56.5 10 to 50 0 0.062 50 66.5 50.5 35 Rc 1/4 64 20 15 6.6 50 8 17 19 18 41 7 80 86 14 M10 x 1.5 11 depth 8 50.5 66.5 75,100 42 58 10 to 50 0
37 29 20 4 LQ3T5A-R12 3/4" 1/4" 26.5 24 32 64 61.5 37 LQ3T6A-R1 24.5 22.5 26.5 24 58.5 56.5 64 61.5 24 32 1/2" 3/4" 26.5 24 64 61.5 37 32 3/4" 7 14 28 26.5 24 70 67.5 37 16 LQ3T6A-R2 1/2" 1" 24.5 22.5 24 64.5 62.5 29 9.5 LQ3T6A-R3 3/8" 1" 22.5 19.5 21 60 57 25 6.4 LQ3T6A-R4 1/4" 1" 17 16 16 50 49 20 4 LQ3T6A-R5 1" 3/4" 30 26 26.5 24 41 32 78 74 70 67.5 49 37 16 LQ3T6A-R6 1" 1/2" 30 26 24.5
32 37 24 61.5 26.5 32 64 37 3/4" 22.5 19.5 24.5 22.5 56.5 51.5 58.5 54.5 24 21 29 25 24 61.5 26.5 64 32 37 7 14 28 22.5 24.5 58.5 56.5 24 29 22.5 24.5 56.5 58.5 24 29 22.5 19.5 56.5 51.5 24.5 22.5 24 21 58.5 54.5 29 25 1/2" 3/8" 24 26.5 64 61.5 32 37 19.5 22.5 51.5 54.5 21 25 22.5 24 24 22.5 19.5 16 26 26 24 56.5 61.5 67.5 62.5 57 49 24.5 26.5 26.5 24.5 22.5 17 30 30 26.5 58.5 64 70 64.5
Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 8-30-64
-1A 1NA SX5000-64-1A 1NA 5-1 2A 2NA 2A 2NA 5-2 SX5000-64-26 SX3000-64-26 Note) For 24 VDC -2A: +COM -2NA: -COM 2A 2NA 2A 2NA 5-3 SX5000-64-20 SX3000-64-20 2A 2NA 2A 2NA 5-4 SX5000-64-10 SX3000-64-10 5-5 SX5000-64-3A SX3000-64-3A In common between +COM and COM. 5-6 SX5000-64-8A SX3000-64-8A M3 x 26, Matt nickel plated SX5000-57-6 6 SY3000-23-4 7 8 SX3000-57-4 VZ1000-11-1-l Refer to page 276
460 460 460 460 460 460 1/8 C6 13/64 VX210 1 5/64 1/8 C8 13/64 5/32 9/32 5/32 9/32 C8 VX220 2 C10 13/64 5/16 C10 25/64 13/64 VX230 3 5/16 C12 25/64 Note) Weight of grommet type.
58 71 72 165 183 196 235 256 175 195 212 255 281 56 64 64 76 76 43 52 52 65 65 11.2 11.2 11.2 12.5 14.0 59 66 66 80 81 1/4 Stroke 1/4 Stroke 1/4 Stroke 1/4 Stroke 1/4 Stroke 173 191 204 244 265 183 203 220 264 290 Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 116 126 100 A clevis pin, flat washers and split pins are included.
20 40 11.5 23 140 64 170 17 11 M10 x 1.25 7 18 80 1001 to 1400 124 13.5 84 40 37 102 32 78 25 52 28 164 198 21 13 M12 x 1.75 10 22 100 1001 to 1500 40 37 140 116 41 92 30 52 13.5 29 180 100 220 21 16 M12 x 1.75 10 26 If a hole is provided to accommodate the rod boot when the air cylinder is mounted, make the hole diameter larger than the outside diameter of the rod boot e.