Model: 40 (Standard, AC Type), Bar Length: 88 (880mm), Emmiter Cartridge, Material: L (High Energy Saving De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 8L (ø8 Elbow), Plug Position: Q (High-voltage Cable Side), Bar Bracket: B (w/Bracket 1), Option: X10 (Non-standard Bar Length)
Model: 40 (Standard, AC Type), Bar Length: 76 (760mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: w/o Plug, Bar Bracket: B (w/Bracket 1), Option: X10 (Non-standard Bar Length)
Part Number Description: 1/8 NPT(F)X10-32(M) ADAPTOR Product Line: C Product Line Description: CONNECTORS Family Code: 732 Family Description: KV FITTING D.O.T. Class Code: BX Part Code: 1 Reference Code: F Click here to report information errorImage shown may not match exact part number
Part Number Description: CONNECTOR FOR VV060-L-08-X10 Product Line: V Product Line Description: VALVE Click here to report information errorImage shown may not match exact part number
Setting Node ID x100 x1 x10 1 0 1 0 2 0 2 0 Caution Outline Dimensions : : : : 238 2 3 8 After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly.
18 to 176 3.5 to 35.5 7 to 71 18 to 176 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Instantaneous Setting/display flow range 1.0 to 38.0 8 to 186 1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 Flow CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Setting/display flow range 0 to 9 ft3 x10
. : The units conversion factor is N value which is used as a power value [x10(N)] for the accumulated flow display / set value of the sub screen. : The setting range of value N varies depending on the flow range. Move on to the switch output NPN/PNP specification switching setting. Press the SET button to set.
The value displayed on the screen is seconds x10. Once the correct value has been selected press the "S" button to set it. Measurement mode Press the SET button for 2 seconds. Menu display Press the UP button 4 times. Menu display Press the SET button. Pressure ramp up duration Press the UP or DOWN button to change the setting. Press the SET button.
EtherNet/IP communication connector 2 P1, P2 Connect Ethernet cable. 3 IP address IP address Switches to set the EtherNet/IP communication IP address (0 to 255) by X1, X10 and X100. 4 SI Serial I/O connector (8 poles) Connector for the teaching box (LEC-T1) or the controller communication cable (JXC-W2A-C). 5 ENC Encoder connector (16 poles) Connect to the actuator cable. 6 MOT Motor driving
50MDC500V 210g() 230g(DIN ) DeviceNet DeviceNet CT-27 Volume1Common Insustrial Protocol(CIP) Edition3.14 Volume3DeviceNet Adaption of CIP Edition 1.13 063 / Data Rate 125/250/500 kbps / Group 2 Only Server EDS 4122036Byte 4 Byte 41020Byte 4 Byte ID 07hSMC Corporation 43h(Generic Device) DDh Polled I/O Explicit 12 - 3.2 10 1 LED 2 DeviceNet DeviceNet 3 Node Address X1 LSD X10
(1)(JXC917-) -14- (2)DIN (JXC918-) 187.9(DIN ) 193.2(DIN ) *DIN (35mm) -15- 3.4. (1) DIN 2 [1](JXC917-) [2]DIN(JXC918-) (2M4) (DIN ) DIN DIN DIN DIN ADIN (2) M4 M4 -16- (1)D (100 ) (2)2mm 2 D (3) 40 30mm 50mm ()60mm 0mm (16 *LEH ) 10mm (25 ) () 30mm 30mm () 50mm (DIN ) 60mm -17- 4 4.1 (IP ) OFF IP 192 168 1 *** *** X100 X10 X1 0 0 0 Remote Control(DHCP) *1 0 0 1 1 0 0
220g(DIN ) 11 - 32 1 LED 2 ADDRESS X1X10 3 B RATE IF X100 4 CN2 SW IF CN2 5 CN4 EMG 6 CN3 Profibus 7 CN2 TB/PC LEC (LEC-T1)(LEC-W2) 8 CN1 CONT IF LEC 12 - 33 1LECGPR1 () (DIN ) DIN (35mm) () 2DIN LECGPR1D DIN (35mm) 13 - 34 1 DIN 2 LECGPR1 DINLECGPR1D DIN 2M4 2.1 Nm DIN A DIN ADIN 2 40 14 - 4 41 ADDRESS,B RATE LEC 0~99 IF 3 ADDRESS B RATE ADDRESS (X10
The variable range is X0.1 to X10. The larger the magnification, the higher the control precision will be, but if the magnification is too large, the sensor will become too sensitive to fluctuation of the load or changes in of the command signal, causing oscillation. I (Integral control action) This function amplifies small deviations (by time integration) and precisely corrects them.
Station number setting Setting Setting range x10 0 to 6 x1 0 to 9 : The station number should be set within the range of 01 to 64. If the number is set to 00, or to 65 or above, the L ERR LED will turn on. : The station number must not be duplicated, this will cause an error. : The default setting is 00.
Address setting switch (x10): Sets the 10 digit of the PROFIBUS DP node address. Address setting switch (x1): Sets the 1 digit of the PROFIBUS DP node address. Settings 2 switch (8): Sets the 3rd digit of the PROFIBUS DP node address.
psig (0.014 to 0.7 MPa) SL5806 1 to 60 psig (0.007 to 0.4 MPa) Operating Parameters Delivery pressure Gas Source pressure Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Select compatible materials of construction for the gas Vacuum to 300 psig (2.1 MPa) 2000 psig (13.8 MPa) 4000 psig (27.6 MPa) 40 to 160C (40 to 71C) (No freezing) 1) 0.4 2 x 10-11 Pam3/sec 2 x10
Those that exceed the standard stroke will have the long stroke dimensions. (2) Exclusive body (-X10)Add stroke. Stroke lengths that exceed standard are long stroke dimensions. 9 10 12 15 M5 X 0.8 M6 X 1.0 M8 X 1.25 10.5 12 14 17.5 M10 X 1.25 Basic (A, B, F and L are different between standard stroke and long stroke.)
(Or None in the Case of No Switch), Made-to-Order: X10 [Long Stroke (101 to 200mm)]
Status LEDs on unit for each output Use with Series (N)VFR, (N)VFS, (N)VZS, ISO valves. 14 N 16 0 IN313-AB1-X10 Allen-Bradley Remote I/O (RIO) compatible Controls up to 16 single solenoid valves. (A combination of single and double solenoid valves as long as the maximum number of solenoid does not exceed 16.)
Made to Order Specifications Oil-free specifications VCB X10 17-2-25 6 Series VCB Construction q w e r Component Parts t Material Description No.