T4 = 0.05 [s] * The conditions for the settling time vary depending on the motor or driver to be used. T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
Piston speed (mm/s) 0.5 to 300 32 Allowable kinetic energy (J) 0.27 0.4 0.65 1.2 40 Manufacture of intermediate strokes at 1 mm intervals is possible.
, 350, 400 WA TF TN Nil PA P OL OB OA U Q T R S PW PB VB VA Bore size Over 100 st 200 st or less Over 25 st 100 st or less 25 st or less 124 124 124 128 Over 200 st 300 st or less 200 200 200 200 Over 300 st 300 300 300 300 32 40 50 63 7.5 7.5 9 9 63 72 92 110 11 11 14 98 106 130 142 48 48 48 52 6.7 6.7 8.6 8.6 44 44 60 70 24 24 24 28 96 104 130 130 78 86 110 124 30 30 40 50 110 118 146
T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] 300 0.5300(0.06 + 0.06) 300 T2 = = = 0.94 [s] L 0.5V(T1 + T3) V T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
, keep the maximum piston speed at 300 mm/s or below to ensure operation of relays or other devices.
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
speed mm/s Piston speed mm/s Piston speed mm/s MY1HT/m MY1HT/m MY1HT/m 1000 1000 1000 500 500 500 300 300 300 MY1HT63 MY1HT63 Load weight kg Load weight kg Load weight kg MY1HT63 100 100 100 MY1HT50 MY1HT50 50 50 50 MY1HT50 40 40 40 30 30 30 20 20 20 10 10 10 100 200 300 400 500 1000 100 200 300 400 500 1000 100 200 300 400 500 1000 Piston speed mm/s Piston speed mm/s Piston speed mm/s
Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200
Valves to drive cylinders of sizes 6 to 200 Pressure: 0.5MPa, Load factor: 50% Cylinder bore size mm Series CJ2 Series CM2 Series MB/CA1 6 10 16 20 25 32 40 40 50 63 80 100 Series CS1 Cylinder speed mm/s Base mounted (sub-plate) Cv 125 140 160 180 200 150 300 450 600 750 150 300 450 600 750 150 300 450 600 750 0.3 SY3000 0.7 SY5000 1.2 SY7000 150 300 450 600 750 SY9000 2.8 The speed of CJ2
300 500600 70 100 300 500600 Maximum speed U (mm/s) Maximum speed U (mm/s)
For AC voltage valves, there is no "S" option.
When the maximum speed exceeds 200 mm/s, the allowable load mass is determined by multiplying the value shown in the graph at 400 mm/s by the coefficient listed in the table below. Maximum Up to 300 mm/s Up to 400 mm/s Up to 500 mm/s Coefficient 1.7 1 0.6 .
For detailed selection procedures, refer to pages 8-11-92 and 8-11-93. 10 10 10 100 200 300 400 500 1000 100 200 300 400 500 1000 100 200 300 400 500 1000 Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) 8-11-90 8-11-91 87 Series MY1HT Model Selection Following are the steps for selecting the most suitable Series MY1 to your application. Calculation of Guide Load Factor 1.
Rated voltage Electrical entry For DC 24, 12 VDC/ 100, 110, 200, 220 VAC DIN terminal M plug connector L plug connector 24, 12, 6, 5, 3 VDC M8 connector Grommet 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC (10-SY5000/7000 only) G: Lead wire length 300 mm L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire WO: Without
Vertical Mounting Slide Bearing MGPS50, 80 1 50mm stroke or less V = 200mm/s 2 Over 50mm stroke V = 200mm/s 300 300 200 200 80 80 100 100 Load weight m (kg) Load weight m (kg) Load weight m (kg) 50 50 50 50 40 40 30 30 20 20 10 10 50 100 200 10 50 100 200 10 Eccentric distance l (mm) Eccentric distance l (mm) 3 50mm stroke or less V = 400mm/s 4 Over 50mm stroke V = 400mm/s 300 300 200 200
Positioning distance (mm) 600 300 100 10 1 10 60.5 30.5 10.5 1.5 0.5 100 6.5 3.5 1.5 0.6 0.5 Speed (mm/s) 150 4.5 2.5 1.2 0.6 0.5 300 2.6 1.6 0.9 0.6 0.5 Values will vary slightly depending on the operating conditions.
Valves to drive cylinders of sizes 6 to 200 Pressure: 0.5MPa, Load factor: 50% Cylinder bore size mm Series CJ2 Series CM2 Series MB/CA1 6 10 16 20 25 32 40 40 50 63 80 100 Series CS1 Cylinder speed mm/s Base mounted (sub-plate) Nl/min 125 140 160 180 200 150 300 450 600 750 150 300 450 600 750 150 300 450 600 750 294.5 SY3000 687 SY5000 1177.8 SY7000 150 300 450 600 750 SY9000 2748.2 The