material Seal material Port size Thread type Rated voltage Electrical entry Oil-free option Bracket option JSXD61 C N 10 R 1 CS None None S F N 2 D B E F 3 4 5 6 7 8 B J JSXD61 Series/Valve type Body material Seal material Port size Thread type Rated voltage Electrical entry Oil-free option JSXD71 B N 12 R 1 CS None F N 2 D E F 3 4 5 6 7 8 B J JSXD71 49 Table of UL-compliant Products
2-Rc 3/8 (plug) DL GA GC 2-Rc 3/8 PB GB J JA 10 WB Q PA + Stroke C + Stroke B + Stroke A + Stroke WA Z JB 6H7 depth 10 FA FB S K E G 6H7 depth 10 With front lock 7 6 HN 10 5 6H7 DM 23 b a Section XX detail e c d End lock mechanism (Locking type manual release) T-slot dimensions (mm) 30 Bore size (mm) a b c d e With rear lock 13.3 20.3 12 8 22.5 80 15.3 23.3 13.5 10 30 100 (mm) Standard stroke
CM2 CG1 MB MB1 CA2 CS1 A 0 to 25 A 0 to 25 MGG MGC B 0 to 50 B 0 to 50 A 0 to 10 MGP B 0 to 25 Note) Specifications other than above are the same as standard type. 0 to 10 (8) MTS 0 to 25 (12 to 40) Precautions Warning 1.
Rod end nut FootAdd foot bracket (#2) to SCQ2 Bore size B, #10. Front flangeAdd front flange (#3) to SCQ2 Bore size B, #10. Rear flange Add rear flange (#4) to SCQ2 Bore size B, #10.
Specify the quantity of units necessary for use with your piping system. 29 Series HRG Dimensions [Dustproof filter set] HRG-FL001 HRG-FL005 A A (10) (25) (25) B (25) (25) (10) B Surface fastener HRG-FL010 A (10) (25) (25) B (390) (390) HRG-FL015 A (10) A (10) (25) (25) (25) (25) B (Large) (Small) B (390) (390) (mm) A B C Part no.
CH2E, CH2F, CH2G, CH2H Stroke range limit charts: Bore sizes 50, 63, 80, 100 Bore size 50 B-rod C-rod 5 2 4 8 3 7 2 4 8 3 7 5 2000 6 1 6 1 1000 Stroke (mm) 500 100 50 0.5 1 5 10 20 30 0.5 1 5 10 20 30 Load (kN) Load (kN) Bore size 63 B-rod C-rod 2000 1 2 8 5 4 3 7 6 1 2 3 5 4 8 7 6 1000 Stroke (mm) 500 100 50 0.5 1 5 10 20 50 0.5 1 5 10 20 50 Load (kN) Load (kN) Bore size 80 B-rod C-rod
CQS Single Acting, Spring Return (mm) D-M9, D-M9W D-M9V, D-M9WV D-A9, D-A9V Bore size (mm) CQ2 Stroke A B W A B W A B W 6 2.5 (5) 6.5 4.5 4 4 0 All stroke 17.5 17.5 13.5 RQ 5, 10 15 5, 10 15 5, 10 15 5, 10 15 5, 10 15 16.5 21.5 20 25 24 29 26.5 31.5 27.5 32.5 16.5 21.5 20 25 24 29 26.5 31.5 27.5 32.5 12.5 17.5 16 21 20 25 22.5 27.5 23.5 28.5 10 1.5 (1) 2.5 0.5 7.5 7.5 3.5 CQM 16 2 (0.5) 2
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
The power supply short circuit detection for the input device Enable Generates an error. Unit 1 Disable Does not generate an error. -10..10 V -5..5 V -10..10 V Selects the analogue input range.
One-touch fitting C10 [3(R) EXH port] (C12 in case of branch type) C10: 10 One-touch fitting (C12: 12 One-touch fitting) R R DIN rail clamp screw 76.5 60 35 25 10 3 3 X X 49.5 12 B B B B B B B B P12 P 30 1 1 A A A A A A A A 13.5 C10 [1(P) SUP port] C10: 10 One-touch fitting C10 [1(P) SUP port] (C12 in case of branch type) C4, C6, C8, [4(A), 2(B) port] 25 C10: 10 One-touch fitting (C12: 12
AL Model Port size A B C D M N P R B B E F G H J K L M5 X 0.8 38.5 50 70.5 70.5 88 88 108 108 108 16 23 26 26 33 36 40 40 40 105 147.5 4.5 5.5 7 7 9 9 12 12 12 50 80 80 80 105 105 105 105 105 91 140 181 181 238 253 300 310 315 5 5 7 7 7 7 10 10 10 7.5 8.5 11 11 13 13 16 16 16 25.5 38 38 38 41 40.5 48 48 48 84.5 124.5 153 153 188 189.5 268 282 282 26 56.8 60.8 60.8 65.5 69.5 75.5 75.5 78 25
Cable colour Terminal No. 8 8m* Vcc B-1 Brown 12 GND A-1 Black 13 A 10m* A B-2 Red 7 A A-2 Black 6 B 15m* B B-3 Orange 9 C 20m* B A-3 Black 8 SD+(RX) B-4 Yellow 11 * Produced upon receipt SD-(TX) A-4 Black 10 of order Black 3 Actuator side Controller side (14.2) (c) (b) (10.2) (5.5 (6.7 (12.7) 6 2 1 (a) (14 (18) A B 5 6 (13.5) 1 3 1 4 2 1 (30.7) (14.7) 15 16 (d) L (10) (11) 10 - [2] Actuator
A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield Cable color Terminal no.
(Red Green Red) D-B59W D-A79W D-A59W D-H7NW/H7PW/H7BW D-G59W/G5PW/K59W D-F79W/F7PW/J79W D-F7NWV/F7BWV D-F59W/F5PW/J59W D-F9NW/F9PW/F9BW D-F9NWV/F9PWV/F9BWV D-Y7NW/Y7PW/Y7BW Band Grommet 10-20-23 Solid state switch Reed switch Rail Grommet 10-20-24 Tie-rod Grommet 10-20-25 2-color indication 10-20-42 Band Grommet RE A B 10-20-43 10-20-44 Rail Grommet REC 10-20-45 Tie-rod Grommet 10-20-46
0.15 17 17 10 0.07 0.15 2 x 4 x M6 x 1.0 4.5 C A R Q Through-hole/Both Ends Tapped Common (Standard) (mm) Clamp stroke 20 mm Clamp stroke 10 mm Bore size A B C Q R S Q R S 20 25 136.5 130.5 69 36 47 25.5 116.5 110.5 59 139 133 69 40 52 28 119 113 59 23 Rotary Clamp Cylinder: Double Guide Type Series MK2T Dimensions: 32, 40, 50, 63 E 4 x F A B E B D 10 D C A F C G Head End Flange (mm) With
b 0.26 0.20 0.22 0.19 b 0.35 0.18 0.21 0.18 C6 C8 C10 C12 C8 C10 C12 C12 10-SS5V1-10 10-SS5V2-10 10-SS5V3-10 10-SS5V4-10 Note) The values are for individually operated 2 position type manifold bases with 5 stations.
Single Acting, Spring Return D-M9, D-F9W D-M9V, D-F9WV D-A9, D-A9V Bore size (mm) Stroke A B W A B W A B W 6 4.5 6.5 4 4 2.5(5) 0 17.5 17.5 All stroke 13.5 16.5 21.5 20 25 24 29 26.5 31.5 27.5 32.5 16.5 21.5 20 25 24 29 26.5 31.5 27.5 32.5 5, 10 15 5, 10 15 5, 10 15 5, 10 15 5, 10 15 12.5 17.5 16 21 20 25 22.5 27.5 23.5 28.5 10 0.5 2.5 7.5 7.5 1.5(1) 3.5 16 0.5 2 8 8 2(0.5) 4 2 20 0 10 10
Double Double Double Double Double Double Double Single Single Single Single Single Single Single Single Single Single SI unit SI unit A B A B A B A B A B A B A B A B A B A B A A A A B A A B A 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 7 8 4 5 9 11 6 10 11 Mixed wiring is available as an option. Use the manifold specification sheet to specify this.
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
Enable Generates an error. 1 Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Sets the analogue input device range per channel. Analogue input range (Range) Selects the analogue input range. -10..10 V 2 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit.