Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-PositionExhaust Center, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: [Rc (R)] Rc, Port Size: 1/8, Connecting Tube Diameter
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Pressure Differential Return), Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): 63 or less, Pipe Port Type: [Rc (R)] Rc, Port Size
Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: R (External Pilot), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: WO (M8 Connector - Without Connector Cable), Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8)
Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: Individual EXH, Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: WO (M8 Connector - Without Connector Cable), Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8)
of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: R (External Pilot), Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: U (Light & Surge Suppressor Non-polar), Manual Override: Non-locking Push Style, A, B Port Size: 01
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: U (Light & Surge Suppressor Non-polar), Manual Override: Non-locking Push Style, A, B Port Size: 01
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: Individual EXH, Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: WO (M8 Connector - Without Connector Cable), Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8)
Function: 2 (Normally Open), Piping: 2 (Body Ported), Body Option: Individual EXH, Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: WO (M8 Connector - Without Connector Cable), Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8)
Safety cannot be assured in the case of unexpected malfunction. x100 x1 x10 6 Seal cap (for M12 connector socket): 5 pcs.
Connecting a wireless adapter (EXW1-A11N-X1) to the M8 "ADPTR" port of the AMS will allow wireless communication. ADPTR port Each of the AMS devices need to be set to pairing mode. Starting with DIP switch 4 of SW 1 in the OFF position, perform the sequence ON >> OFF >> ON. The SF/MS/ST and BF/NS/DIAG/SA LEDs of each device will flash red. Connect to the webserver.
UP/DOWN X1 X2 X4 X4 4 SEL. UP DOWN SEL. (4) FUNC. FUNC. 1 LEFT/RIGH UP/DOWN SEL. SEL. (5) FUNC. FUNC. LEFT/RIGH SET SEL. SET FUNC. FUNC. FUNC. FUNC. -2 SEL. UP LEFT/RIGH OFFSET SEL. UP/DOWN SET SEL. 17 - DOWN -3 FUNC. FUNC. FUNC. FUNC. SEL. LEFT/RIGH STOP SEL. UP/DOWN UP 0.1 SET SEL. DOWN -4 FUNC. FUNC. FUNC. FUNC. SEL. UP/DOWN SET SEL. OUTPUT SEL.
(no condensation and freezing) range Storage humidity 90%RH or less (no condensation) range Note1) Controller initial communication settings Communication speed (bps): 38400 Silent interval: x1 Communication delay time (ms): 5ms Teaching box is automatically recognize the communication speed. 12 - 2.
Display Description Detail 1 LED lamp LED to indicate the condition of the gateway unit 2 ADDRESS Address switch This switch sets X1 and X10 in the address. 3 B RATE Communication speed The switch to set the communication speed of the controller IF communication line.
Table. 7-3 Digital input allocation and the process data Connector position Connector designation X0 X1 X2 X3 X4 X5 X6 X7 Pin 2 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 Input Pin 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 -41No.EX##-OMU0020-A 7.5.
P2, L5 X1 S/S . P3, L10 1 2 1 2 1/2 B Thd D A Thd C Hole Dia. Stainless Steel Threaded Parts Page & Part No. Line No. Page & Part No. Line No. D Line No.
(650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Fluid Air VR Operating pressure 0.1 to 1.0 MPa Ambient temperature and operating fluid temperature 5 to 60C (No freezing) VH Handle switching angle 90 Required switching force 73.6 N (at 1.0 MPa) Paint color (Standard) Handle: Black, Body: Platinum silver Note) VHS Note) Handle: Silver, Body: Red (Made to order -X1
Type of seal Special Options R Rubber S Metal Standard X1 External Pilot Supply Size 6 Size 1 8 Size 2 10 Size 3 Pilot Exhaust Options Pilot Exh. through footprint V1 External Individual Pilot Exhaust Configuration FG 2-position Number of Solenoid Subplate (NPTF) FHG 3-position, Closed center FJG 3-position, Exhaust center Without Subplate A02T Side 1/4 For VSR/S8-6 S Single D Double FIG
ll9#x1'&l?3flrin c8-se of (6so)sr=13.6ks 1s) a=1366=6.6s catculation formuta tor cr (o<1) 3ff9i,3?
ll9#x1'&l?3flrin c8-se of (6so)sr=13.6ks 1s) a=1366=6.6s catculation formuta tor cr (o<1) 3ff9i,3?
Model no. 1 3 5 A VZ X1 ( ) VZ3 A ( ) Manual override Entry is the same as standard products. Entry is the same as standard products.