SMC Corporation of America
Elite Part Number Search
Search Results "CM2D40TN-300Z-XC4"

Magnet: Built-in Magnet, Mounting: Rod Trunnion, Type: Rubber Bumper, Bore: 63mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 300mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewire Connection: 3m, Number: 2 pcs

Magnet: None, Mounting: Clevis, Type: Air Cushion, Bore: 63mm, Port Thread Type: TN [NPT ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion), Stroke: 300mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: No Switch, Lead Wire or Prewire Connection: 0.5m (Or None in the Case of No Switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread type

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BAV, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: G, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Magnet: None, Mounting: Boss-cut, Basic, Bore: 20mm, Port Thread: Rc, Stroke: 300mm, Cushion: None, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: w/Heavy Duty

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: G, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BAV, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread type

Symbol Specifications Heat resistant cylinder (150 C) -XB6 -XB13 Low speed cylinder (5 to 50 mm/s) -XC3 Special port location Water Resistant Air Cylinders -XC4 With heavy duty scraper As compared to the standard cylinder, anti-coolant performance has been improved, and suitable for using under the atmosphere having coolant in the machine tools.

Made to Order Common Specifications: -XC4: With Heavy Duty Scraper With Heavy Duty Scraper 16 It is suitable for using cylinders under the environment, where there are much dusts in a surrounding area by using a heavy duty scraper on the wiper ring, or using cylinders under earth and sand exposed to the die-castied equipment, construction machinery, or industrial vehicles.

Use the heavy duty scraper type (-XC4) in situations where there is a lot of dust. Use a water resistant cylinder when there is splash or spray of liquids. 3. When using auto switches, do not operate in an environment with strong magnetic fields. Caution 1. Drain flushing Remove drainage from air filters regularly. (Refer to the specifications.)

(Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty Scraper), Suffix: W (XC4, XC35: w/Scrapper Both Ends)

(Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty Scraper), Suffix: W (XC4, XC35: w/Scrapper Both Ends)

(Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty Scraper), Suffix: W (XC4, XC35: w/Scrapper Both Ends)

(Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty Scraper), Suffix: W (XC4, XC35: w/Scrapper Both Ends)