Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 700mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 140, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Solid State Switch: D-M9B, D-M9N, D-M9P, D-F9BW, D-F9NW, D-F9PW Stroke B Stroke E Model A 10 20 30 40 75 100 125 150 10 20 30 125 40 50 150 75 100 50 B MXQ6 0.5 0.5 0.5 7.5 7.5 9.5 9.5 9.5 17.5 17.5 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MXQ8 26 2 2 6
150 500 250 250 824 846 (mm) A 531 570 494 527 B 444 479.8 444 479.8 C 3/8 1/2 3/8 1/2 D Note) 519 543 Booster regulator model The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
Calculating motor speed conversion example using an actuator with a 20mm lead and 500 [mm/sec] speed.
Rz 12.5 45 Female thread size Chamfered dimension D (Recommended value) M5 5.1 to 5.4 10-32UNF 5.0 to 5.3 2. Use G external threads with G internal threads. D For Uni Thread 45 Tightening method 1.
U D U D Thread type Nil Rc F G N NPT T NPTF Refer to page 534 (Grommet type) for wiring specifications.
Auto Switch Mounting Height (mm) D-B5 D-B64 D-B59W D-G5 D-K59 D-G5NT D-G5W D-K59W D-G5BA D-G59F Auto switch model D-F5 D-J59 D-F5W D-J59W D-F5BA D-F59F D-F5NT D-Z7 D-Z80 D-Y59 D-Y7P D-Y7BA D-Y7W D-A9 D-M9 D-M9W D-M9A D-A3C D-G39C D-K39C D-A44C D-A9V D-M9V D-M9WV D-M9AV D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-Y69 D-Y7PV D-Y7WV Bore size (mm) Ht Hs 40 50 63 80 100 Hw Hs Ht Hs Ht Hs Ht Hs
How to Order B 20 30 D C CQSY Without auto switch F9BW S B 20 30 D C CDQSY With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
Z 11 Lead wire min. bending radius 10 Auto switch D-A7, A8 K M E S J B + Stroke A + Stroke L Rod end male thread H1 Rod end nut C1 X L1 Rod End Male Thread (mm) Bore size (mm) 63 Auto switch D-A9, F9 C1 X H1 L1 26 28.5 M18 x 1.5 33.5 80 32.5 35.5 M22 x 1.5 43.5 100 32.5 35.5 M26 x 1.5 43.5 (mm) Without auto switchWith auto switch Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P
M Special specifications Mixed M D D side In the case of mixed specifications (M), indicate separately on the manifold specification sheet.
250 143 1000 500 250 Different from the initial value. *5.
Hs Reed switch D-A44 A A 49.5 Auto switch 19 Series CH2E/CH2F/CH2G/CH2H JIS Standard Hydraulic Cylinder Double Acting: Single Rod Auto switch mounting height Unit: mm D-B5/B6 D-B59W D-G5/K59 D-G5W/K59W D-G5BAL D-G59F/G5NTL D-F5/J5 D-F5W/J59W D-F5BAL/F59F D-F5NTL D-A5/A6 D-A59W D-A3 D-G39/K39 D-A44 Bore size (mm) Hs Ht Hs Ht Hs Hs Hs CH2E 35 29.5 35 29.5 33.5 CH2F 34.5 30 34.5 30 32 32