bolt A Adjustment amount by adjustment bolt B Adjustment amount by adjustment bolt B Adjustment amount by adjustment bolt B 90 Rotation 90 Rotation 90 Rotation 278 Rotary Table/Rack & Pinion Style Series MSQ Construction CRB2 CRBU2 CRB1 MSU CRJ o i t !
CRQ2X MSQX MRQ Auto Switch Working Principle [Pressure is applied from the B port.] The auto switch B is turned ON by the magnet B in the state that the pressure is applied from the B port and the piston B moves to the left side. At this time, the auto switch A turns OFF . Magnet B Piston B A port B port Auto switch B Auto switch A [Pressure is applied from the A port.]
C A B C A B C A B C A B C A B C LEY40 1100 Work load [kg] 1 1.5 3 2.5 5 10 4.5 9 18 7 14 28 1 1.5 3 1.2 2.5 5 Lead 4: LEY40C 800 900 1000 Pushing force 85% 65% 85% 65% 95% 95% Lead 8: LEY40B Lead 16: LEY40A 10 20 30 40 50 60 70 80 90 0 100 200 300 400 500 600 700 Force [N] Non-rotating Accuracy of Rod Size Non-rotating accuracy q 16 1.1 25 0.8 32 0.7 40 + Max. 65% Set value of pushing force
Solid State Auto Switch: D-M9B, D-M9N, D-M9P, D-M9BW, D-M9NW, D-M9PW Stroke B Stroke E Model A 40 50 150 10 20 30 40 75 100 125 150 10 20 30 125 75 100 50 B MXS6 -0.4 -0.4 -0.4 11.6 17.5 9.6 9.6 9.6 21.6 27.6 10 MXS8 4.9 -0.1 0.9 8.9 16.9 41.9 14.9 9.9 10.9 18.9 51.9 26.9 11.6 MXS12 32.4 22.4 12.4 14.4 45.4 74.4 24.4 22.4 12.4 2.4 4.4 14.4 35.4 64.4 15.6 MXS16 32.7 22.7 12.7 12.7 42.7
Next, B is entered to find A the inertial moment for the rotation of shaft (A) as 5 b a A = ( ) 2 B Number of teeth = b Kinetic Energy/Rotation Time Even in cases where the torque required for rotation of the load is small, damage to internal parts may result from the inertial force of the load.
B B B B B B A A A A A A A Bore size 125 140 160 180 200 4 4 8 8 1.5 1.5 0 0 2 2 4.5 4.5 9.5 9.5 4 4 8 8 1.5 1.5 0 0 2 2 4.5 4.5 9.5 9.5 4 4 8 8 1.5 1.5 0 0 2 2 4.5 4.5 9.5 9.5 9.5 7.5 13.5 12.5 7 5 3.5 1.5 7.5 5.5 10 8 15 13 12 10 16 14 9.5 7.5 6 4 10 8 12.5 10.5 17.5 15.5 The mounting position should be referred for reference only for the auto switch mounting position at the stroke end
In the case of mounting auto switch from B direction Step 2) Insert the auto switch into the auto switch installation groove from direction B. A B Step 3) Slide the auto switch in the direction of the arrow until the indicator light illuminates. Step 3) Slide the auto switch in the direction of the arrow until the indicator light illuminates.
V) 0.10 to 0.20 MXP6 MXP10 0.05 to 0.15 MXP12 MXP16 Solid State Auto Switch D-M9B(V), D-M9N(V), D-M9P(V) Solid State Auto Switch D-M9B(V), D-M9N(V), D-M9P(V) (mm) Stroke (mm) 20 41 29 41 29 47 35 Stroke (mm) Auto switch mounting screw (attached to auto switch) Model Model 25 46.5 34.5 30 55 43 10 31 19 31 19 15 36.5 24.5 5 25.5 26.5 13.5 14.5 10 30.5 31.5 18.5 19.5 A B C D A B A B A
(Extension) q w A B Air pressure supplied from B operates on surfaces e. (Retraction) A B e Improved workpiece mounting accuracy Positioning holes on the workpiece mounting surface allow easy alignment. Say goodbye to nonrotating guides!!
Auto switch (mm) Auto switch model D-A90 D-A93 D-M9N D-M9P D-M9B SMC CLS125 MODEL b a a b a b Bore size CLJ2 FREE LOCK CHECK 125 140 160 180 200 250 62 42 58 46 70.5 50.5 66.5 54.5 CLM2 Cylinder With$ Locking Mechanism 70.5 50.5 66.5 54.5 80.5 60.5 76.5 64.5 CLG1 86 66 82 70 102 82 98 86 CL1 Be sure to confirm operation after mounting.
Material: Carbon steel 20 Series MU Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V B B A A Hs Hv D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A9 D-M9V D-M9WV D-M9AVL Size A B A B Hs Hv A B A B Hs Hv 25 5 5 5 5 7.5 27.5 1 1 1 1 32 5 5 5 5 14.5 30 1 1 1 1 40 5.5 5.5 5.5 5.5 16.5 37 1.5 1.5 1.5 1.5 50 7
U B A CHA B A Related Products D-F7 D-F7W D-J79 D-J79W D-A7 D-A7H D-A8 D-A8H D-F7V D-F7WV D-F7BA D-F7BAV D-F7NT D-F79F D-J79C D-A73C D-A80C 32 to 100 DApprox. U B A Approx.
"#$ S Q J K E B ! "#$ A !
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
Low Speed Cylinder Double Acting, Single Rod Series CQSX 12, 16, 20, 25 How to Order CQSX D B 20 30 Without auto switch 30 F9BW B 20 CDQSX D With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
Example Rail mounting style CDJ2XB10-45-A Band mounting style CDJ2XB16-60-B Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
There are two types of alarm reset: alarm reset manually (a) and an alarm reset externally (b) by an external signal.
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Magnet: D (With Magnet), Mounting: B (Basic), Bore Size: 50mm, Port Thread Type: TN (NPT), Stroke: 100mm, Rod End Nut: A (With Rod End Nut), Cushion: With Cushion in Both Sides, Port Position: B (Port on Top - Cushion Valve Down), Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical
Magnet: D (With Magnet), Mounting: FZ (Rear Rectangular Flange Type), Bore Size: 50mm, Port Thread Type: Rc, Stroke: 100mm, Rod End Nut: A (With Rod End Nut), Cushion: With Cushion in Both Sides, Port Position: B (Port on Top - Cushion Valve Down), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)