mA PNP open collector Max. 30 VDC, 50 mA NPN open collector Max. 30 VDC, 50 mA PNP open collector Max. 30 VDC, 50 mA RS Q G Output transistor mode 80 to 120 VAC 50/60 Hz 21.6 to 26.4 VDC Power supply voltage RS H A 10 VA or less 5 W or less Power consumption RZQ Between case and AC line: 1500 VAC for 1 min.
moment of inertia [kgm2] Allowable moment of inertia [kgm2] 102 102 MK 103 103 50, 63 Standard arm single unit 32, 40 Standard arm single unit 104 50 100 200 104 50 100 200 Maximum piston speed [mm/s] Maximum piston speed [mm/s] 386 Model Selection MK Series Note) Maximum piston speed is equivalent to approximately 1.6x the average piston speed.
Nil (Example) A93 3m .
Load Mass Allowable Moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 q r w e t 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load mass kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 D3 3 3 3 MY2H16 -X 2 2 2 2 0.2 MY2H16 MY2H16 Individual -X MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300
Nil (Example) A93 3m . L (Example) A93L 5m .
(N) 32 12 0.3 0.5 Deflection (mm) Deflection (mm) MTS32-200 st 175 st 150 st 125 st 100 st 75 st 50 st 25 st 0.2 MTS12-100 st 75 st 0.1 50 st 25 st 0 50 100 0 5 10 Lateral load (N) Lateral load (N) 40 16 0.3 0.3 MTS40-200 st 175 st 150 st 125 st 100 st 75 st 50 st 25 st Deflection (mm) Deflection (mm) 0.2 0.2 MTS16-100 st 75 st 50 st 25 st 0.1 0.1 0 50 100 150 0 10 Lateral load (N) Lateral
Note 1) Perpendicular electrical entry is not available for 50 and 63.
Bore size/Stroke (mm) 6 10, 20, 30, 40, 50 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Adjuster option Nil Without adjuster Functional option AS Extension end adjuster AT Retraction end adjuster Nil Standard A Both ends adjuster P Note) Axial piping CS Extension
50 5 0 Z X Mass and center of gravity of the load 25 Center of gravity 50 Load no.
M2 m2 M3 m3 25 32 40 23 26 23 27.5 27.5 27.5 MY1H 39 50 39 39.2 39.2 39.2 50 50 39 50 50 50 The above values are the maximum allowable values for moment and load mass.
[mm] L2 = 50 [mm] 1 = W/Wmax MXF Item Load factor n Note Va MXW W Examine W.
Fittings & Tubing Air Cylinders Rotary Actuators 4.5 8 11-MXJ4 Model 11-MXJ6 11-MXJ8 6 M3 x 0.5 Air Double acting 0.15 to 0.7 MPa 1.05 MPa 10 to 60C Bore size (mm) Piping port size Fluid Action Operating pressure Proof pressure Ambient and fluid temperature Suction flow rate L/min (ANR) Size 4 6 8 1 1 1 Operating speed range (Average operating speed) Note) 50 to 500 mm/s (Metal stopper: 50
(Roll moment) Moment MXW25 120 70 (Static moment/Dynamic moment) Allowable Moment MXW25 70 100 50 (Nm) 30 40 Maximum moment (Nm) Maximum moment (Nm) 50 MXW20 25 30 40 Roll moment Pitch moment Yaw moment MXW20 20 Model Mr Mp/Mep My/Mey 15 MXW16 20 MXW16 12 10 15 3 5 5 MXW8 7 10 MXW12 MXW12 2 10 10 MXW12 4 5 7 5 4 3 12 20 20 MXW16 MXW8 MXW8 3 2.5 25 40 40 MXW20 2 2 1.5 50 100 200 300 500 65
Lateral load F = mg [N] (g: Gravitational acceleration = 9.8 [m/s2]) Mass of transferred object m [kg] RSQ RSG Friction coefficient RS2H RS2H RSH P: Operating pressure of the cylinder [MPa] MIW MIS D-X 593 Heavy Duty Stopper Cylinder 50, 63, 80 RS2H Series RoHS How to Order D 30 RS2H 50 L M9BW Bore size 50 63 80 50 mm Port thread type Number of auto switches (auto switch number mounted)
force (Max.) 550 860 1340 2140 Series Variations Bore size (mm) Cushion Standard stroke (mm) Lock direction Manual release Model 10 15 20 25 50 75 100 Non-locking type Front lock CBQ2 Rubber bumper 32, 40, 50, 63 Rear lock Locking type Series CBQ2 How to Order B 50 D C 32 H L CBQ2 Standard A93 S B 50 D C CDBQ2 With Auto Switch 32 H L Number of auto switches With auto switch (built-in magnet
Standard Strokes Bore sizes (mm) Standard strokes (mm) 20 & 25 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 32 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75 40, 50, 63, 80, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Made to Order Pages 22 to 24 Manufacture of Intermediate Stroke Cylinders Hydraulic Fluid Compatibility Intermediate strokes in 5mm increments can be manufactured by installing spacers
Nil 6 50, 100, 150, 200 1 pc.
Models suitable to satisfy the requirement of 100 (N) are CY332 or CY340. 300 100 200 50 100 20 30 40 50 10 Useable range 10 5 5 Useable range 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10111213 7 8 9 1 01 11 21 3 1 41 5 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B25 500 300 200 100 20 30 40 50 10 Useable range 5 1 0 1 2 3 4 5 6 7 8 9 10111213 Distance
type) Displacement m Displacement m 200 200 150 150 130 120 50 50 MSZA30A (High precision type) MSZA50A(High precision type) D70 60 50 40 30 20 10 0 120 100 80 60 40 20 0 Load N Load N 291 Rotary Table Air Consumption Air consumption is the volume of air which is expended by the rotary tables reciprocal operation inside the actuator and in the piping between the actuator and the switching
mm/s Piston speed mm/s Piston speed mm/s (4) CY1F/m1 (5) CY1F/m2 (6) CY1F/m3 (7) CY1F/m4 30 30 30 30 20 20 20 20 CY1F25 CY1F25 CY1F25 CY1F25 10 10 10 10 CY1F15 CY1F15 CY1F15 5 5 5 5 Load mass kg Load mass kg Load mass kg Load mass kg 4 4 4 4 3 3 3 3 CY1F15 CY1F10 CY1F10 CY1F10 2 2 2 2 CY1F10 1 1 1 1 0.5 500 300 100 50 0.5 500 300 100 50 0.5 500 300 100 50 0.5 500 300 100 50 Piston speed mm