SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B40-100DZ-L-A93"

Magnet: Built-in, Mounting: Foot, Bore Size: Ø50, Stroke: 100mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number

Magnet: Built-in, Rod Type: Standard, Mounting: Both Ends Tapped, Bore Size: 100mm, Stroke: 100mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 40mm, Stroke: 100mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 50mm, Stroke: 100mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 63mm, Stroke: 100mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 80mm, Stroke: 100mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Rod Type: Standard, Mounting: Both Ends Tapped, Bore Size: 32mm, Stroke: 100mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Rod Flange, Port thread type: Rc, Body Options: -, Auto Switches: A93

[Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole (standard), Port thread type: Rc, Body Options: -, Auto Switches: A93

): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A93

Magnet: -, Mounting: -, Bore Size: -, Stroke 1: -, +: -, Stroke 2: -, Body Option: -, Auto Switch Groove: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Stroke Options: -

[Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole (standard), Port thread type: Rc, Body Options: -, Auto Switches: A93

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Rod Flange, Port thread type: Rc, Body Options: -, Auto Switches: A93

Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) IN 236 165 118 71 20 10 OUT 314 220 157 94 IN 378 264 189 113 25 12 OUT 491 344 245 147 Intermediate Strokes Method Model no. Installation of spacer on standard stroke body. Refer to page 1 for standard model no. Intermediate strokes at 1 mm intervals are available by using spacers with standard stroke cylinders.

30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25

Lead wire length (m) Load voltage Direct mounting Rail mounting Indicator light Applicable load Special function Type Electrical entry Wiring (output) 12 to 50 32 to 50 None (N) 0.5 (Nil) 3 (L) 5 (Z) AC DC In-line In-line Perpendicular Perpendicular 3-wire (NPN equiv.)