It is already built-in to the rectifier circuit. 50 60 100 VAC Hz 1 2 200 VAC Hz 50 60 50 60 110 VAC Hz [115 VAC Hz] 3 Electrical entry 50 60 50 60 50 60 DIN terminal D With connector 4 220 VAC Hz [230 VAC Hz] DO Without connector DC specifications of type "D" and "DO" is only available with 12 and 24 V DC. Power saving circuit is not available in the case of "D", "DO" type.
Example) S2S2: Standard cable (2 m) + Driver (LECSS2) S2 : Standard cable (2 m) Nil : Without cable and driver Stroke (mm) Model 200 300 400 500 700 600 800 900 1000 1200 1500 2000 3000 LEJB40 LEJB63 D ) D D D ) ) D D D D ) ) D D ) ) D ) D D D D D 3: Strokes other than those shown above are produced as special order (1 mm increments). For auto switches, refer to pages 19, 20.
Operating Range (mm) Auto switch model Bore size (mm) 9.5 9.5 11.5 12 20 32 40 50 63 D-A9(V) 7 9 9.5 D-M9(V) D-M9W(V) D-M9A(V) 2.5 4 6 6 6 6.5 D-A7(H)(C) D-A80(H)(C) 9.5 12 12 11 10 12 D-A79W 11.5 13 13 14 14 16 D-F7(V) D-J79(C) D-F7W(V) D-F7BA(V) D-F7NT D-F79F 4 5.5 6 6 6 6.5 D-X Since the operating range is provided as a guideline including hysteresis, it cannot be guaranteed (assuming
Spacer with Bracket: (Z) G F.R.L. body center C BB (Y100T, Y200T only) E 1 X-X EE (Y100T, Y200T only) RELEASE X B 2 E X A G Seal Y200T Y400T F J H K D Applicable models F 6.8 12 14 18 18 20 G 4.5 5.5 7 9 9 11 H 14 19 21 26 27 31 J 2.8 3.2 4 4 4.6 6.4 K 25 30 41 50 50 70 A 6 3 4 5 5 6 B 82 96 96 120 BB 56 67 C 24.5 29 41 48 48 60 D 40.5 53 68 81.5 86 112 E 20 24 35 40 40 50 EE 27 33 G 4.5
47.5 43.5 50 40 42 47.5 48.5 54.5 51 54 50 56.5 REB REC Operating Range CY (mm) Bore size Auto switch model 32 40 50 63 CX D-A9 (V) 9.5 9.5 9.5 11.5 MQ D-M9 (V) D-M9W (V) D-M9A (V) L D-A7 (H) (C) D-A80 (H) (C) 6 5.5 6 6.5 RHC 12 11 10 12 RZQ D-A79W 13 14 14 16 D-F7 (V) D-J79 (C) D-F7W (V) D-F7BA (V) D-F7NTL D-F79F 6 6 6 6.5 D-X D-P4DW 5 5 5 Individual -X Since the operating range is provided
Write sequentially from the 1st station on the D side.When part nos. written collectively are complicated, specify by using manifold specification form. 3 position closed center 3 position exhaust center 3 position pressure center Indicator light and surge voltage suppressor Seal Yes No E Rubber 0 1 Metal Coil voltage Pilot valve 1 2 3 4 5 6 100V AC(50/60Hz) 200V AC (50/60Hz) 110V AC (50
Solid State Switch: D-M9B, D-M9N, D-M9P, D-F9BW, D-F9NW, D-F9PW Stroke B Stroke E Model A 10 20 30 40 75 100 125 150 10 20 30 125 40 50 150 75 100 50 B MXQ6 0.5 0.5 0.5 7.5 7.5 9.5 9.5 9.5 17.5 17.5 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MXQ8 26 2 2 6
A B C D E EE F G H J K Applicable size Y200T-D 3.2 67 29 51 24 33 11.5 5.5 15.5 3.5 30 JSXM20 Y300T-D 4.2 85 42.5 67.5 35 14 7 20 6 41 JSXM30 Y400T-D 5.2 115 50 85.5 40 55 18 9 26 7 50 JSXM40 45 JSX10, 20, 30 Series Table of UL-compliant Products * Refer to the table below for UL-compliant products.
A B C D E EE F G H J K Applicable model Y200T-D 3.2 67 29 51 24 33 11.5 5.5 15.5 3.5 30 AFF/AM/AMD/AMK20 Y300T-D 4.2 85 42.5 67.5 35 14 7 20 6 41 AFF/AM/AMD/AMK30 Y400T-D 5.2 115 50 85.5 40 55 18 9 26 7 50 AFF/AM/AMD/AMK40 Part no.
D-A79W BQ-1 D-F7l, J79, D-F7lV D-J79C D-F7lW, J79W, D-F7lWV D-F7BAL, D-F7lF, D-F7NTL 32/40 50/63 BQ-2 40/50 63 D-P5DW BQP1-050 The set of stainless steel mounting screws (with nuts) described below is available and can be used depending on the operating environment.
Auto Switch Mounting Height (mm) D-Z7/Z80 D-Y5/Y6 D-Y7P D-Y7PV D-Y7W D-Y7WV D-Y7BAL Hs D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL Hs Auto switch model D-A9 D-A9V D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A3 D-G39 D-K39 D-A5 D-A6 D-A59W D-A44 Bore size (mm) Ht Ht Ht Ht Ht Hs Hs Hs Hs Hs D125 140 160 180 200 69 69.5 71.5 69.5 69 69.5 116 126 75.5 69.5 74.5 70 -X 76 76 77.5 76 76 76 124 134
Position (Detection at Stroke End) and Its Mounting Height D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V 20 to 63 B A Hs 32 to 63 D-P3DWA B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5
D-Y7P D-Y69 D-Y7PV D-Y7W D-M9V D-F9WV D-Y7WV D-M9 D-F9BAL D-F9W Model MHS 4 8 1 6.5 3 1.5 Open Closed Open Closed Open Closed Open Closed MHZJ2-10 With dust cover No setting No setting MHC MHZJ2-16 No setting No setting MHT MHZJ2-20 MHY MHZJ2-25 MHW Note) There is no auto switch protrusion from the body's end surface.
2 L MRHQ 0 10 20 30 40 50 60 0 50 100 150 Misc.
Coil voltage CE-compliant 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Caution Use the standard (DC) specification when continuously energizing for long periods of time. 383 VQ1000/2000 Series Kit (D-sub connector) F VV5Q11 < >: AC The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS].
Operating Range (mm) Auto switch model Bore size 12 16 20 25 32 40 50 63 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V 6.5 5 5 5 5.5 5 4 3 11 9.5 9.5 9 9 10 7.5 6 D-F7/J79 D-F7V/J79C D-F7W/F7WV D-J79W D-F79F/F7BA D-F7BAV/F7NT 7.5 6.5 6.5 6 6 6 Since this is a guideline including hysteresis, not meant to be guaranteed (assuming approximately 30% dispersion).
Coil voltage 3 m 1 3 5 6 100 VAC (50/60 Hz) 110 VAC (50/60 Hz) 24 VDC 12 VDC 52 Series VQ2000 kit (Circular connector) M VV5Q21 < >: AC The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D].