7 M A Rated flow range Calibration certificate 501 5 to 500 L/min 102 10 to 1000 L/min 202 20 to 2000 L/min Nil None A Note 8) Yes Note 8) Made to Order: Certificate in both English and Japanese Thread type Option 2 Nil Rc N NPT F G Note 1) Nil No bracket With bracket Note 7) Note 1) ISO228 compliant Port size R Symbol Port size Rated flow range 501 102 202 04 1/2 V V 06 3/4 V Note 7
* C D H* Description None Mounting Bracket Float Auto Drain (N.C.)
* C D H* Description None Mounting Bracket Float Auto Drain (N.C.)
Symbol -X80, -X81 Main Value Double Acting Type 1 A N 06 5 1 4 VP31 1 D Z X81 Body size CE marking Nil Q None CE-compliant 4 6 8 1/2 1 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2 2 Port size (IN, OUT port) Thread type Symbol VP3145 VP3165 VP3185 Port size Nil F N T D/DO/DZ/DU only Rc G NPT NPTF 03 04 06 10 12 14 20 Type of actuation X80 X81 Double solenoid Single solenoid External pilot Passage, Type
Panel cut dimension 2 x 3.2 16.5 14.5 11 8.2 20 2 x 3.2 2 x 3.2 M3 thread hole 8.2 8.2 P U P S U H S H L O L C O K C K R V R S W V X S W T 19 T X 19 L2=50+T+X L2=50+T+X L1=50+R+V 14 L1=50+R+V 14 Pressure gauge (Accessory) 50 Pressure gauge (Accessory) 50 55 (at knob locked) 55 (at knob locked) IN OUT IN OUT 41.5 43.5 U Y 4 25 6 25 U Y 14 14 SMC SMC 2 x 3.2 2 x 3.2 42 42 IN side OUT side IN
, D-F9P, D-F9B Auto Switch Specifications Grommet D-F9 (with indicator light ) D-F9B D-F9N D-F9P Auto switch part no.
fitting Sensor (Breathing port) PB H G C PA A B N E J B (F) R 2-V PB PA A B Pilot port threaded type (mm) Dimensions A B C D E F G H J K L M N P Q R V Model LVD1-S LVD2-S LVD3-S LVD4-S LVD5-S 4 (5/32") 20 20 45 39 9.5 46 23 11.5 4.5 11 30 5 21 28 22.5 M5 x 0.8 30 30 54.4 56 11 67 28.5 13 4 20 44 7 23 31.5 17 M5 x 0.8 6 35 35 79.5 62 17.5 83 45.5 14.5 6 22 50 7 37 6 36 21 M5 x 0.8 35 35 82
(Normally open) B VP Valve option Electrical entry S070 Nil For general G Grommet Conduit terminal DIN terminal TL D V For vacuum/low pressure T VQ Port size (IN, OUT port) Conduit terminal with indicator light TS Conduit terminal with surge voltage suppressor TZ Conduit terminal with light/surge voltage suppressor DL DIN terminal with indicator light DS DIN terminal with surge voltage suppressor
) 4 AC 200 V 2.3 (With light: 2.4) 2.5 (With light: 2.6) [2.7 (With light: 2.8)] 220 V [230 V] 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) Surge voltage suppressor Diode (Non-polarity type: valistor) 3 position exhaust center 3 position exhaust center (B) 2 (A) 4 (B) 2 (A) 4 Indicator light LED In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
center Apparent power VA (B) 2 (A) 4 (B) 2 (A) 4 AC 200 V 2.3 (With indicator light: 2.4) 2.5 (With indicator light: 2.6) [2.7 (With indicator light: 2.8)] 220 V [230 V] 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) Surge voltage suppressor Diode (Non-polarity type: valistor) 3 position exhaust center 3 position exhaust center (B) 2 (A) 4 (B) 2 (A) 4 Indicator light LED In common between 110 VAC and 115
V O Speed max 10ms ON OFF BUSY BUSY ON OFF max 60ms V O Speed Response time with respect to controller input signals Timing for alarm reset The following requisites exist for delay of response with respect to controller input signals.
(mm) Model Model Accessory TM-04 TM-06 TM-08 2 x 6 TM-04 TM-06 TM-08 TM-10 TM-12 4 6 8 10 12 2.6 x 8 4 TM-10 3 x 8 TM-12 Dimensions: Multi-tube Holder N x D (Pitch) N x holding part Cutting groove for separation N (No. of holding parts) Applicable tubing O.D.
Grommet (G) Rated voltage DIN terminal (D) Part no. symbol Standard: Y, V, W Continuous duty type (E) Standard: Y, V, W Continuous duty type (E) W/o indicator light With indicator light W/o indicator light With indicator light W/o indicator light With indicator light Varistor Varistor Diode Diode Coil Coil Coil Coil S AC Vacuum Spec.
Evaporation thermometer V Dustproof filter provided as a standard accessory V All electrical components are located in the front of the product.
(With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3 selections) Yes 1% F.S.
24 V or less 100 V 0 0.1 0.2 0.3 0.4 Pressure setting scale Maximum operating current and range 40 mA 50 mA 20 mA Impact resistance 30 G 14-4-21 4 Series ARM11A Flow Characteristics Condition: Inlet pressure 0.7MPa Condition: Inlet pressure 0.5MPa ARM11AA1-307 (One-touch fittings: IN 6, OUT 4) ARM11AA1-307-1 (One-touch fittings: IN 6, OUT 4) 0.35 0.6 0.7 0.30 Outlet pressure MPa Outlet pressure
24 V or less 100 V 0 0.1 0.2 0.3 0.4 Pressure setting scale Maximum operating current and range 40 mA 50 mA 20 mA Impact resistance 30 G 14-4-21 4 Series ARM11A Flow Characteristics Condition: Inlet pressure 0.7MPa Condition: Inlet pressure 0.5MPa ARM11AA1-307 (One-touch fittings: IN 6, OUT 4) ARM11AA1-307-1 (One-touch fittings: IN 6, OUT 4) 0.35 0.6 0.7 0.30 Outlet pressure MPa Outlet pressure
It is already built-in to the rectifier circuit. 2 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 Electrical entry 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] D With connector DIN terminal DO Without connector DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.
Body Size: -, Thread: -, Port: -, Option: -, Attachment: -, Semi-Standard 1: -, Semi-Standard 2: -
Auto switch type D-A3, A4 D-G3, K3 D-B5, B6 D-G5, K5 D-A5, A6 D-F5, J5 Cylinder bore size (mm) Bore size (mm) Standard stroke (mm) Long stroke (mm) Model 1800 (1401 or more with tie-rod reinforcing ring) Note 2) 32 25 to 800 32 40 50 63 80 100 32 40 50 63 80 100 32 40 50 63 80 100 BA-32 BA-04 BA-05 BA-06 BA-08 BA-10 BAF-32 BAF-04 BAF-05 BAF-06 BAF-08 BAF-10 BGS1-032 BH2-040 BH2-050 BA-06