SMC Corporation of America
Elite Part Number Search
Search Results "52-IP8101-034-M"

Mounting orientation and static moment Mounting orientation Static load Horizontal mounting Ceiling mounting Wall mounting Vertical mounting Bore size (mm) A [mm] 6 10 15 20 25 32 40 m m x g x x m x g x y 19 21 25 27 33 40 49 m x g x x m x g x y m x g x (z + A) m x g x x m x g x (z + A) m x g x y M1 M2 M3 Static moment A: Distance between the center of the guide shaft and the upper surface

The arm dimensions other than M dimensions are the same as those of with arm. 6.6 (2 locations) M6 x 1.0 (2 locations) (Special cap bolt) M MM FX FZ Arm 8 FV (mm) Rod Flange M MM Model Rod state Clamp stroke 20 mm 30 mm Clamp stroke 20 mm 30 mm 10 mm 10 mm Head Flange Model (mm) Retracted Extended Retracted Extended 24 43.5 24 43.5 34 63.5 34 63.5 12.5 32 12.5 32 22.5 52 22.5 52 44 83.5 44

Applicable auto switch lead wire length(m) Load voltage Auto switch part No.

Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Besides the above models, there are some other auto switches that are applicable.

max) + Dynamic moment (ME) n = Load weight (m) Max. load weight (m max) + Static moment (M) Determination of maximum load weight Allowable dynamic moment (ME max) m>mv m>mv (Refer to pages 32 through 34 for determination of the load factor (n).

Add L to the end of the part number when 3 m is desired, M when 1 m, and Z when 5 m.

(Initial value) Base mounted Solenoid specifications Grommet(G)/(H), L plug connector (L), M plug connector (M), DIN terminal (D), M8 connector (W) Electrical entry JIS Symbol G, H, L, M, W D Internal pilot Rated coil voltage V DC AC50/60Hz 24, 12, 6, 5, 3 24, 12 10-SYJ51 M 2 4 10-SYJ52 M 2 4 100, 110, 200, 220 10% of rated voltage Allowable voltage fluctuation (A) 2 (A) 2 Standard 0.35

(M) -45D (M) x 110L 110 135 x 135L -50D (M) -50D (M) x 115L 115 140 x 140L -75D (M) -75D (M) x 140L 140 165 x 165L -100D (M) -100D (M) CHQWB100-10D (M) x 165L 165 190 x 190L CHQWB40-5D (M) CQ-M5 x 75L CQ-M10 x 105L 75 105 -15D (M) -10D (M) x 80L 80 x 110L 110 -20D (M) -15D (M) x 85L 85 x 115L 115 -25D (M) -20D (M) x 90L 90 x 120L 120 -30D (M) -25D (M) x 95L 95 x 125L 125 -35D (M) -30D (M

INP(IN )() INP ON INP LEHF20K2-24 MAX. 28N JAPAN 100 ) P.50,P.52 8.3 15 - No.

Use piping whose I.D. is 6.5 or larger, and whose length is 5 m or less. Avoid riser piping. AD17/27: Use piping whose I.D. is 2.5 or larger AD37/47: Use piping whose I.D. is 4 or larger Length is 5 m or less. Avoid riser piping.

Note 3) Value on option "V", "M" (Non-leak, vacuum).

Nil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z : Manufactured upon receipt of order. 6-13-4 4 Series CP95 ISO/VDMA Cylinder: Standard Type Double Acting w/ End of Stroke Cushioning Accessory Mounting Accessory, Cylinder Female head side clevis (Corresponds to E accessories) Rod/Head side flange Male head side clevis F D C Bore size (mm) CJ1 CJP Supplied with bolt, safety device

Nil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z : Manufactured upon receipt of order. 6-13-4 4 Series CP95 ISO/VDMA Cylinder: Standard Type Double Acting w/ End of Stroke Cushioning Accessory Mounting Accessory, Cylinder Female head side clevis (Corresponds to E accessories) Rod/Head side flange Male head side clevis F D C Bore size (mm) CJ1 CJP Supplied with bolt, safety device

Operation of the main exhaust When pressure is applied the the actuation port M (7) on model XLD, or the main exhaust solenoid valve (26) is turned ON with port P in a pressurized state on model XLDV, the piston M (8) moves upward opening valve M (13). Port S (10) remains pressurized and valve S (18) remains open.

Operation of the main exhaust When pressure is applied the the actuation port M (7) on model XLD, or the main exhaust solenoid valve (26) is turned ON with port P in a pressurized state on model XLDV, the piston M (8) moves upward opening valve M (13). Port S (10) remains pressurized and valve S (18) remains open.

Particle diameter (m) Particle diameter (m) Front matter 23 Comparison of Cleanliness Standards ISO 14644-1 ISO Cass 1 to 9 Intermediate classes available U descriptor: Particles smaller than 0.1 m M descriptor: Particles larger than 5.0 m Standard Fed.Std.209E British unit: Class 1 to 100.000 SI unit: Class M1 to M7 U descriptor: Particles diameter smaller than 0.1 m (SI unit) (British

Speed 600 mm/s REAR20 3 1 9 9.5 5.2 22.8 9 6 39 37.5 39 36 38 36 7.5 21 M6 x 1 x 8 REAR25 3 1 8.5 9.5 5.2 27.8 8.5 6 44 42.5 44 41 43 41 6.5 23.5 M6 x 1 x 8 REAR32 3 1.5 10.5 11 6.5 35 10.5 7 55 53.5 55 52 54 51 7 29 M8 x 1.25 x 10 Direct Mount Type REBR REAR40 5 2 10 11 6.5 43 13 7 65 63.5 67 62 66 62 8 36 M8 x 1.25 x 10 LD MM N P PW Q WS Z QW T W X Y K L M Model REAR10 3.5 M3 x 0.5 4.5

Manual release, Lock type While pushing the M/O knob, turn it 90 counterclockwise. The lock is released (and remains in a released state) by aligning the mark on the cap with the OFF mark on the M/O knob. When locking is desired, turn M/O button clockwise 90 while pushing fully, correspond on cap and ON mark on M/O button. The correct position is confirmed by a click sound click.

FV 40 44 5.5 8 54 61 30 to 100 50 49.5 6.6 9 67 67.5 mm 4-FD FT Bore size (mm) FX FZ L L1 M L FX FZ B + Stroke A + Stroke 32 34 17 65 38.5 56 40 40 17 72 38.5 62 Rod end male threads 50 50 18 89 43.5 76 Flange material: Carbon steel Rod end nut L1 Rear flange type Rear flange type/RQG, RDQG mm Bore size (mm) Stroke range (mm) A L L1 20 to 100 32 7 28.5 52 20 to 100 40 59 7 28.5 FV M 30 to