VX3 VXA VN Turbine Oil Class 1 ISO VG32 (with no additives) Referential number of the expected life span (Under room temperature, with fresh water)/Volume to be discharged per 1 cycle LVC ISO viscosity grade 32 Viscosity classification cst (40C) Idemitsu Kosan Co., Ltd. Nippon Mitsubishi Oil Corp. Cosmo Oil Co., Ltd. Japan Energy Corp. Kygnus Sekiyu Co. Kyushu Oil Co.
OUT Standard specification Option Note) Water (Standard, up to 40C) Air (Standard, Dry) Turbine oil Vacuum (up to 1.3 x102 Pa) Carbon dioxide (CO2), Nitrogen gas (N2) Vacuum (up to 1.3 x101 Pa) (V, M) Non-leak (106 Pa m3/s or less) (V, M) IN N.O.
Applicable Fluids Standard Option (1) Water (Standard, Up to 40C) Air (Standard, dry), Turbine oil Vacuum (Up to 1 Torr) Carbon dioxide (CO2), Nitrogen gas(N2) Freon11, 113, 114 Vacuum (Up to 103 Torr) (V, M) Non-leak (105 atm cc/sec or less) (V, M) Symbol N.C.
Fluid 5 to 40C (41 to 104F) Operating temperature C 0.2M to 1 x 10 -6 {1.5k to 7.5 x 10 -9} Operating pressure Pa {Torr} 5 8 5 8 Conductance l/s 1.3 x 10 -8 {1 x 10 -7} at ordinary temperatures, excluding gas permeation 1.3 x 10 -11 {1 x 10 -10} at ordinary temperatures, excluding gas permeation Internal External Leakage Pa m3/s {Torr l/s} KF16 KF25 KF16 KF25 Flange type/size Principle materials
ZSE2-0R-15 Air 0 to 101 kPa 3% or less 3% Full span (5 to 40C) 5% Full span (0 to 60C) 12 to 24 VDC (Ripple 10% or less) Open collector 30 V, 80 mA Lights up when ON 17 mA or less (when 24 VDC is ON) 0.2 MPa Fluid Setting pressure range Hysteresis Compact size: 39H x 20W x 15D (except the connecting portion) ZX Temperature characteristics Improved wiring: Connector style Operating voltage
Fluid Set pressure range Hysteresis ZY Air 0 to 101 kPa 3% Full span or less 3% Full span (5 to 40C) 5% Full span (0 to 60C) 12 to 24 VDC (Ripple 10% or less) M5 x 0.8 Note) If not operated within the specified range of pressure and temperature, trouble may be caused. ZQ 1% Full span Accuracy ZF Voltage Port size ZP ZCU AMJ Misc.
Viscosity according to ISO Grade 32 Classification of viscosity (cst) (40C) Turbine oil P-32 Idemitsu Kosan Co.,Ltd. Caution Turbine oil 32 Nippon Mitsubishi Oil Corp. Cosmo turbine 32 Cosmo Oil Co.,Ltd. Series LV Kyodo turbine 32 Japan Energy Corp. Turbine oil 32 Kygnus Oil Co. 1.
Products are tested from -40F to 200F (-40C to 93C) per FMVSS 49CFR571.106. How to Order TIV 07 B 33 Length per Roll Conversion 33 77 153 305 Tube Model Feet Feet Feet Feet Meters 33 77 153 305 108 252 500 1000 Meters Meters Meters Meters = = = = See Packaging Table below. Not Available in all sizes and all colors.
Operating Pressure Specifications Fluid Air/Water 20C 0.8 5.0 Max. operating pressure (MPa) 40C 0.65 Max. operating pressure (MPa) 4.0 60C 0.5 Applicable fittings FR one-touch fittings: KR-W2 series 3.0 Ambient and fluid temperature 20 to +60C Water: 0 to 40C (No freezing) Internal tubing Polyurethane 2.0 Material Outer layer Polyolefin (Equivalent to UL-94 standard V-0) Note) The color of
Operating Pressure Max operating pressure (MPa) 40C 0.65 60C 0.5 Applicable fittings One-touch fittings 5 Max. operating pressure (MPa) Min. bending radius (mm) 18 24 30 36 10 4 Operating temperature 20 to 60C Material Polyurethane 3 How to Order 2 1 TUH0644 B 20 0 -20 0 20 40 60 Operating temperature (C) Length per roll Tubing model Length 20 m roll 100 m roll Symbol 20 100 Precautions Be
Measure 2R when the tube breaks or is crushed. 40C 0.65 60C 0.5 Fixed end One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Min. bending radius (mm) 4 10 15 20 27 35 10 15 23 27 35 45 20 to +60C (Water: 0 to 40C) (No freezing) Operating temperature Material Polyurethane 465 TU/TIUB Series How to Order 20 TU0425 BU Length per roll Tubing model
Power Block Specifications Model EX9-PE1 Output block (EX9-OEP) Connection block EX Output block: Max. 9 stations (excluding input blocks) Note 1) Connection block stations Power supply for output and internal control 22.8 to 26.4 VDC Power supply voltage 20 mA or less Internal power consumption Max. 3.1 A (When using with 3.0 to 3.1 A, the ambient temperature should not exceed 40C, and do
Turbine oil P-32 Viscosity according to ISO Grade Classification of viscosity cst (40C) Classification of viscosity cst (40C) 32 32 a. Cut the tube perpendicularly, being careful not to damage the outside surface. Use SMC tube cutter TK-1, TK-2 or TK-3. Do not cut the tube with pliers, nippers, scissors, etc., otherwise, the tube will be deformed and troubles may result. b.
(mm) 2.2 2.5 4 5 6.5 8 MS Black (B) T Max. operating pressure (at 20C) 1.2 MPa Burst pressure VMG Refer to the burst pressure characteristics curve. 12 15 19 27 32 12 Minimum bending radius (mm) Operating temperature 0 to 40C Burst Pressure Characteristics Curve and Operating Pressure Material Conductive nylon + Flame resistant nylon (Equivalent to UL-94 standard V-0) 104 to 107 Surface
1.8 (50) Horizontal: 17.6 (500), Vertical: 3.5 (100) Optical linear encoder (incremental) Sensor 30 None 1.25 Provided 30 None 1.25 Provided 30 None 1.25 Provided Pushing operation 6 1 to 4.8 1 to 5 1 to 3.9 Positioning operation Positioning repeatability (m) Note 4)5) Accuracy (m) Note 4)5) 90 5 90 5 90 5 Measurement Maximum speed (mm/s)Note 6) 100 10 100 10 100 10 400 41 to 104F (5 to 40C
Next, pour water at 5 to 40C, then measure the flow rate with a pressure differential of 0.075 MPa. However, the pressure differential needs to be set with a large enough difference so that the Reynolds number does not go below a range of 4 x 104. By substituting the measurement results for formula (8) to figure out Av.
Cooling capacity None Nil C D N Z Analog communication Symbol 001 002 004 008 Cooling capacity DeviceNet communication 1 kW NPT fittings 2 kW Temperature range setting Circulating fluid automatic recovery 4 kW Temperature range setting 1 kW 2 kW 4 kW 8 kW Symbol L H W 8 kW 20 to 40C 20 to 90C 20 to 90C Specifications (For details, please consult our Product Specifications information.)
ACG20 to 40 AF + ARG + [S] + AL (7) Pressure switch S AF + [S] + ARG ACG20B to 40B ACG20C to 40C AF + AFM + [S] + ARG ACG20 to 40 AF + ARG + AL + [V] Residual pressure relief 3 port valve AW + AL + [V] ACG20A to 40A Port size AF + ARG + [V] V ACG20B to 40B Body size Port size ACG20C to 40C AF + AFM + ARG + [V] Symbol 20 30 40 AW + AFM + [V] ACG20D to 40D 01 02 03 04 1/8 Note 6) When more
FR one-touch fittings: Series KR-W2 Metal one-touch fittings: Series KQB2 Applicable fittings 0.8 MPa At 20C Max. operating pressure 0.65 MPa At 40C How to measure the minimum bending radius 0.5 MPa At 60C Burst pressure Refer to the burst pressure characteristics curve.
Grease Grease-free R Clockwise L Counterclockwise Body material A2017 Weight (g) 12.5 49 114 206 310 * Air purication rating: JIS B 8392-1 (ISO8573-1) Quality Degree 4, 4, 2 or more 2A 3A Low profile cyclone type Outer body diameter (mm) 20 25 Piping port size 1.6 Fluid Air* XT661 X260 2A R Operating pressure 0.01 to 0.5 MPa Proof pressure 0.75 MPa Ambient and operating temperature 5 to 40C