\u/ (6oomm) Lead wire length :12 inch (300mm) L: L type plug connector with lead wire H"rt#'" mhrin*n" : 12 inch | ll-l.r :12 inch (3oomm) "!
12 14 16 18 20 30 Hz Discharge time (s) Discharge time (s) 1 Hz 30 Hz 1 Hz 0 500 1,000 1,500 2,000 0 500 1,000 1,500 2,000 Installation distance (mm) Installation distance (mm) Supply pressure: 0.3 MPa (17.6 L/min [ANR] per cartridge) Supply pressure: 0.3 MPa (8.6 L/min [ANR] per cartridge) 12 12 10 10 Discharge time (s) Discharge time (s) 8 8 6 6 30 Hz 1 Hz 30 Hz 1 Hz 4 4 2 2 0 0 0 500
Name Material Remarks 1 Body Stainless steel 2 Spool Special stainless steel 3 Sleeve Special stainless steel 4 Plate Aluminium 5 O-ring H-NBR 6 Retaining ring Carbon steel 7 Retaining ring Carbon steel 8 Radial bearing MQR2 to 12-M5 Components / (MQR2 to 12 M5, 2 to 12 circuits) No.
12 12 12 305.3 305.3 605.3 605.3 Note 1) Note 1) Nozzle size 1 1.5 2 2.5 1 1.5 2 Nozzle size 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 1.5 2 1.5 2 Type Nozzle model KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 KNH-R02-100 KNH-R02-150 KNH-R02-200 Type Nozzle model KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 KNL3-06-150 KNL3-06-200 KNL6-06-150 KNL6-06-200 Low noise nozzle with male thread
Supply should be "1", the outputs 2'and "4', the pilot port connecting"l" with 2" is then "12" etc. Table 7.2 shows the tour main sets of port identifications in use. Preterred are now the numbers.
Supply should be "1", the outputs 2'and "4', the pilot port connecting"l" with 2" is then "12" etc. Table 7.2 shows the tour main sets of port identifications in use. Preterred are now the numbers.
, 350, 400, 450, 500, 600, 700, 800 12-REA40 12-REA50 50 1300 Non-lube 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 12-REA63 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special orders.
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
Proper tightening torque Nm Tightening torque for piping (ftlb) Connection threads M5 1.5 to 2 (1.11 to 1.48) Rc 1/8 7 to 9 (5.16 to 6.64) Rc 1/4 12 to 14 (8.85 to 10.33) Rc 3/8 22 to 24 (16.23 to 17.70) Reference Tightening of M5 fitting threads After tightening by hand, tighten approximately 1/6 turn further with a tightening tool.
Exhaust heat Exhaust heat Exhaust heat from air dryer Reduced by 25% 12 kW 9 kW Air conditioner Air conditioner Exhaust heat Exhaust heat 1 2 Indoor Indoor Outdoor Exhaust heat from new air dryer 1 Exhaust heat from F type current air dryer 2 Condition: The IDF100F is operated with the rated condition of 60 Hz.
If turned forcibly, it will damage the connector port. 1 2 3 4 Brown White Blue Black Power supply Signal COM Monitor Wiring 2: (White) 4: (Black) 3: (Blue) 1: (Brown) Wiring diagram Current signal type Voltage signal type Brown Brown Blue Blue Vs Vs White White Black Black A Vin Vs: Power supply 24VDC 12 to 15VDC Vin: Input signal 0 to 5VDC 0 to 10VDC Vs: Power supply 24VDC 12 to 15VDC A
An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 12 Actuator Precautions 1 Series MGZ Be sure to read before handling. Precautions on Design Selection Warning Warning 1.
a) .250 \-24 0.50 .624 .621 0.25 0.86 0.38 it-l6 .251 .zfi 0.75 0.25 o.34 It.oo o.75 o.62 o.12 # 1 8 o.75 1-?
Refer to pages 11 and 12 regarding manifold additions. 10 Compact Direct Operated 2 Port Solenoid Valve for Water and Air Series VDW10/20/30 Manifold Exploded View Bracket assembly Passage pipe assembly 2 station manifold base 3 station manifold base Bracket assembly Connecting plate assembly Connecting plate assembly Figure shows VV2DW2.
(mm) H I J K L B U Z A N O P S C D E F M Bore size (mm) 32 M10 x 1.5 60 4.5 14 8.5 65 31.5 14 82 5.5 9 depth 7 Rc 1/8 58.5 12 16 45 20 34 40 M10 x 1.5 69 5 14 8.5 67 35 14 84 5.5 9 depth 7 Rc 1/8 66 12 16 52 22 40 50 M12 x 1.75 86 7 18 11 76 41 19 98 6.6 11 depth 8 Rc 1/4 80 15 20 64 25 50 63 M12 x 1.75 103 7 18 11 80 47.5 19 102 9 14 depth 10.5 Rc 1/4 93 15 20 77 27 60 80 M16 x 2 132 6 22
Manual override 'H:Grommet G:Grommet Lead wire length :24 inch(6o0mm) Lead wire length :12 inch (3o0mm) L:L type plug connector With lead wire . 6: Lead wirg ;f,Jfll renetr \)/ :12 inch (3o0mm) M:M type plug connector With lead wire LO: L type plug connector Without connector DIN connector ,&
Manual override 'H:Grommet G:Grommet Lead wire length :24 inch(6o0mm) Lead wire length :12 inch (3o0mm) L:L type plug connector With lead wire . 6: Lead wirg ;f,Jfll renetr \)/ :12 inch (3o0mm) M:M type plug connector With lead wire LO: L type plug connector Without connector DIN connector ,&
Recommended Tightening Torque [Nm] Connection thread Pressure Control Equipment 1/2 3/8 1/4 1/8 Torque 28 to 30 22 to 24 12 to 14 7 to 9 2. Avoid excessive torsional moment or bending moment other than those caused by the equipments own weight as this can cause damage. Support external piping separately. 3.
plate type heat exchanger (IDFB4E to 75E) AMD Power supply voltage: Single-phase 115 VAC (60 Hz) 230 VAC (60 Hz) Three-phase 460 VAC (60 Hz) AMH AME Air flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(10C) IDFB3E IDFB4E IDFB6E IDFB8E IDFB11E IDFB15E IDFB22E IDFB37E IDFB55E IDFB75E NPT3/8 10(17) 11(19) 12