Note 11) If the product is used at altitude of 1000 m or higher, refer to Operating Environment/Storage Environment (page 210) Item 14 * For altitude of 1000 m or higher. 200 A Thermo-chiller Basic Type HRSE Series Note 1) If the product is used at altitude of 1000 m or higher, refer to Operating Environment/Storage Environment (page 210) Item 14 * For altitude of 1000 m or higher.

Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.

(2-color indicator) 2-wire 12 V 24 V Grommet Yes Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V 2-wire 12 V 3-wire (NPN equivalent) Reed auto switch Z76 IC circuit 5 V Yes Grommet 100 V Z73 IC circuit Relay, PLC 24 V 12 V 2-wire Z80 100 V or less Lead wire length symbols: 0.5 m Nil (Example) Y7BW 3 m L (Example) Y7BWL 5 m Z (Example) Y7BWZ Solid state auto switches marked

Select zero cut-off setting (flow rate) Press the UP or DOWN button to select the value of zero cut-off. : The display above is an example of when [L] is selected for the PF3A801H (1000 L/min type) with the unit switching function. : If the flow rate does not reach the above value, the display will be zero. Example: PF3A801H (1000 L/min type) Press the SET button to set.

Note 11) If ON is selected for key lock setting, the setting is held even if the power is turned off and on again. 3)When error occurs CPU failure CPU failure Power supply failure (High voltage power supply Incorrect high voltage Communication error (controller) module) Error codeE1 Error codeE3 Error codeE4 Error codeE0 Error codeE2 Display Status Note 12) Note 12) Note 12) Note 12) Power

to 1000 to 1000 to 1000 B FD FE FT FX FY FZ Fd Port Cushion valve 32 40 50 63 80 100 4-FD 50 55 70 80 100 120 3 3 2 2 4 4 10 10 12 12 16 16 64 72 90 100 126 150 32 36 45 50 63 75 79 90 110 120 153 178 25 31 38.5 39.5 45.5 54 7 9 9 9 12 14 Fd B FY FT FE FX FZ Without air cushion Rear flange type/(G) Bore size (mm) ZZ Cushion valve Port 4-FD 32 40 50, 63 80, 100 147 151 172 212 Rear flange

02 M8 connector (WO): SYJ74-WO01 02 VZ VS VFN Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 89.6 Max. 10 58 [65] 91.5 84 42.6 62.5 72.7 M8 x 1 45 69.1 [76.1] Approx. 300 (Lead wire length) Pg7 80.6 [82.8] 90.6 70.8 [73] 79.7 72.3 65.8 23 15 23 15 23 15 23 15 48 48 48 48 12 12 12 12 20 20 20 20 54.5 54.5 54.5 54.5 57.6 Refer to page 4-4-61 for dimensions with connector cable

V IC circuit Reed switch Solid state switch 12 V Diagnostic indication (2-color display) 5 V,12 V IC circuit Relay, PLC Grommet 24 V Yes 12 V 5 V,12 V IC circuit Water-resistant (2-color display) 12 V Magnetic field resistant (2-color display) 2-wire (Non-polar) 3-wire (NPN equivalent) A96V A96 IC circuit 5 V U U Yes 24 V Grommet A93V A90V A93 A90 IC circuit 100 V 12 V 5 V,12

Maximum piston speed: 1000 mm/s It can be used at 50 to 1000 mm/s provided that it is within the allowable kinetic energy range.

and up) SUS304 (6 and 8) Aluminum (12 and up) SUS304 (6 and 8) Aluminum (12 and up) Material Piston Anodized (12 and up) Chromate (12 and up) Electroless Ni-plated (6 and 8) Chromate (12 and up) Treatment SUS304 SUS303, SUS304 Iron SUS304 SUS303 Iron Brass Electroless Ni-plated Brass Electroless Ni-plated Iron Material Air slide table MXQ Piston spacer Treatment Material Packing support

(3) AD F7FFF -3276732767 ()() 15 V 15 V 5000 1000 10001 V 20002 V 30003 V 40004 V 50005 V (5 V-1 V)(5000-1000)1/1000 15 V 1/1000 AD (ab) [V] [mA] 16 10 010 V 15 V 05 V 020 mA 420 mA FFFE7FFF -3276632767 10 5 5 20 20 F7FFE -3276732766 0 1 0 0 4 Byte0 Byte1 CH0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB Byte2 Byte3 CH1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD

Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) Model 15 20 25 30 LG1H21NC-500-F LG1H21NC-600-F LG1H21NC-700-F LG1H21NC-800-F LG1H21NC-900-F LG1H21NC-1000-F 1000 1000 700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 930 740 600 500 Consult SMC if outside of the above conditions. 55 Series LG1H Construction/ With Coupling LG1H21 q r y !

V = 1.4 x 300 = 420 1 420 2 E = 0.2 () = 0.018 2 1000 V = 1.4 x 300 = 420 1 V 2 E = W () 2 1000 1 V 2 E = W () 2 1000 Find the kinetic energy E (J) of the load.

Standard dew point temperature and air flow rate Outlet air flow rate Purge air flow rate Flow rate by size l/min (ANR) Standard dew point C Symbol Drain discharge method (Mist separator, Micro mist separator, Micro mist separator with pre-filter ) 10 100/25 20 200/50 30 300/75 50 60 3 25/6 25/3 75 100 5 50/12 50/6 20 15 500/125 600/125 750/150 1000/190 Nil H L Size and standard dew point

8 20 0 0.033 13 10.5 8 41 5 28 5 6 12 M8 x 1.25 24 M20 x 1.5 1/8 9 11.5 25 22 19.5 17 8 22 12 10 26 0 0.033 13 10.5 8 45 6 33.5 5.5 8 12 M10 x 1.25 30 M26 x 1.5 1/8 9 11.5 32 22 19.5 17 10 27 20 12 26 0 0.033 13 10.5 8 45 6 37.5 5.5 10 15 M10 x 1.25 34.5 M26 x 1.5 1/8 12 14.5 40 24 21 22 10 33 20 14 32 0 0.039 16 13.5 11 50 8 46.5 7 12 15 M14 x 1.5 42.5 M32 x 2 1/4 12 14.5 Dimensions by

5.5.1 Alarm buzzer sound setting . 5-12 5.5.2 Alarm buzzer sound setting and checking . 5-12 5.6 Alarm customize function . 5-13 5.6.1 Alarm customize function. 5-13 5.6.2 Alarm customize function setting and checking . 5-13 5.6.3 Setting of temperature alarm monitoring method and alarm generation timing . 5-21 5.7 Data reset function . 5-23 5.7.1 Data reset function . 5-23 5.7.2 Method

OUT2 [ HYS] Hysteresis mode [2ot ] Switch operation of OUT2 [ 2_P] Normal output 50% of maximums rated flow range [ 250] 250 L/min (500 L type) [ 500] 500 L/min (1000 L type) [1000] 1000 L/min (2000 L type) [P_2 ] Set value of OUT2 [F 2] 3 Page 42 5% of maximums rated flow range [ 25] 25 L/min (500 L type) [ 50] 50 L/min (1000 L type) [ 100] 100 L/min (2000 L type) [H_2 ] Hysteresis of OUT2

PROFINET SD0 Serial kit without SI Unit VQC 4/5 VQC 4/5 32 M12 1 to 12 stations SNB 16 1 to 8 stations (12 stations, 16 points) SNC 32 D-sub Note 3) 1 to 12 stations SND 16 1 to 8 stations (12 stations, 16 points) SVA CC-Link 32 M12 1 to 12 stations SVB 16 1 to 8 stations (12 stations, 16 points) SDA EtherCAT 32 M12 1 to 12 stations SDB 16 1 to 8 stations (12 stations, 16 points) SFA PROFINET

Caution MGP with Air Cushion MGP with Rubber Bumper 1000 1000 100 80 63 50 40 32 100 100 80 63 100 25 20 50 10 Load mass [kg] Load mass [kg] 40 16 12 32 1 25 10 20 16 0.1 0.01 1 100 1000 500 100 1000 500 Maximum speed [mm/s] Maximum speed [mm/s] MGP without Cushion (MGP-lV (Water resistant), XB6, XC9, XC22) 1000 100 80 63 50 40 32 100 Load mass [kg] 25 20 10 16 12 1 0.1 0.01 100 1000 Maximum