SMC Corporation of America
Elite Part Number Search
Search Results "11-MXJ4L-10CTP-M9N"

D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.

(The selection should allow a sufficient margin because the value calculated by the selection software involves an error with reference to the actual value.) m3max m1max m2max Weight kg MY340 20 30 40 50 Collision deceleration G 1500 N 10 5 4 3 2 1 40 30 20 10 5 4 3 2 1 m3 max m1 max m2 max Weight kg 8-14-11 11 Series MY3A/3B Model Selection 2 Calculation of Guide Load Factor 1.

Moving Parts: With Magnet for Auto Switch [g] 100 Allowable lateral load at rod end [N] 80 Bore size [mm] Cylinder stroke [mm] 63 5 10 15 20 25 30 35 40 45 50 50 40 32 12 6 7 8 9 10 11 10.0 16 7 8 9 10 11 12 20 16 17 19 21 23 25 27 29 31 33 25 25 25 28 31 34 37 40 43 46 49 53 20 32 43 48 52 57 61 66 70 75 79 83 16 40 69 75 81 87 93 99 105 111 117 123 1.0 12 50 127 137 147 157 167 177 187

[mm] Adjustment bolt (Mountable on either right or left) A Model A B C D E F MM MHL2-10DZ-X28 22 15.5 2.5 7 4 2 Max. when adjusted: E M5 x 0.8 MHL2-10D1Z-X28 11 16 MHL2-10D2Z-X28 11 16 MHL2-16DZ-X28 27.5 18.5 3 8 B 9.5 9 M6 x 1 MHL2-16D1Z-X28 13.5 20 MHL2-16D2Z-X28 13.5 20 MHL2-20DZ-X28 32.5 21 4 12 MM 7.5 7 M8 x 1 MHL2-20D1Z-X28 8.5 9 MHL2-20D2Z-X28 8.5 9 MHL2-25DZ-X28 38 26 5 Closing stroke

NS 14 14 24 24 30 30 45 55 60 LT 42 42 52 52 62 62 72 82 92 LB 20 25 30 LA 10 10 20 20 30 30 20 25 30 J 4 4 4 4 4 4 6 6 6 Stroke (mm) 5 10 15 20 25 30 40 50 60 24 Compact Slide MXH Series Dimensions: 10 LT MXH MXH 19 11 MXS MXQ 11 LA LB J x M4 x 0.7 Depth 6 MXQ 3 x M5 x 0.8 through Pilot hole dia 4.3 2 x 3 x 7.5 counterbore depth 4.4 MXF 2 x 2 x M5 x 0.8 Cylinder port (With plug for port)

rc 1o Indcale thewnnO spec l.ar ons n the specilicalion sheet Note 4) F.r exlenal pr ol oplDn, F ndca|elhe qter.a p otsp6licaton R fordre appricabre var@s as @11 Note 5) The o!

(Refer to Table 11 (P21)) Before mounting a support bracket, make sure the product is aligned by placing on the leveled surface. It is recommended to secure the mounting screws temporarily to insure alignment before tightening with the specified torque. Fig 3. Order for tightening mounting screws 11 2-10.

29.5 31 25 11.5 14 16.5 26 28.5 7.5 10 12.5 30 32.5 32 12 13 15.5 25 27.5 8 9 11.5 29 31.5 40 15 20 20 32 32 11 16 16 36 36 50 14.5 21 21 33 33 10.5 17 17 37 37 The value of W in the table means the amount of auto switch protrusion from the body end surface.

Fittings & Tubing Air Cylinders Rotary Actuators How to Order 11 Vacuum suction type Clean series 11 M D H R 3 10 R M9B S 22 M D H R 3 10 R M9B S Copper, fluorine and silicone-free + Low particle generation Number of auto switches 2 pcs. 1 pc.

Bottom mounting Bottom mounting Application Example Assembly lines, inspection lines etc. with turning operations Front mounting Side mounting Series Variations Bearing type Bore size (mm) Standard stroke (mm) Model Slide bearing MGTM 63 80 25, 50, 75, 100, 125, 150, 175, 200 Ball bushing bearing MGTL 100 8-24-2 3 Cylinder with Turntable Series MGT 63, 80 100 How to Order MX MTS M 63 50 11

In this case, consider using larger size or external stopper (buffer mechanism) to stop the load itself. 11 5-2Kinetic Energy Allowable kinetic energy of CRB2BW40 is 0.04 (J) when rubber cushion is used, and it is 0.03 (J) when rubber cushion is not used.

MY1B40 26.5 Rc1/8 80 35 70 10 16 8 51 16 10 16 28.5 12 20 55 280 Rc1/16 264 48 16 11 32 40 Rc1/4 100 85 12 18.5 9 59 23.5 14 20 35 14 67 340 Rc1/8 40 23.5 322 60.5 24 12 35 47 Port Variations Bottom Ported MY1BG Y Y Head cover piping connection can be freely selected to best suit different piping conditions.

Lead wire length (m) Auto switch model MHC Electrical entry direction Load voltage Pre-wired connector Applicable load 5 (Z) Type Electrical entry Special function Indicator light Wiring (Output) 0.5 (Nil) 1 (M) 3 (L) DC AC Perpendicular In-line MHT M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW M9NA 3-wire(NPN) IC circuit 5 V, 12 V 12 V 3-wire(PNP) Solid state auto switch MHY

For details, refer to page 8-30-31. 8-3-11

For details, refer to page 8-30-31. 8-3-11

(s P. 11 ) (2) The weight of a transferred object and transfer speed should be within the allowable range as shown in the graphs. (3) Overhang L3 should be 30 mm or less. V m L3 30 mm Caution (1) If a load is applied in the direction as shown on the right side, an eccentric load will be applied to the guide.

(Product with a lead wire length of 0.5 m is not available.) 18 Prior to Use Auto Switches Common Specifications 2 Refer to the Auto Switch Precautions on pages 8 to 11 before using auto switches. Meaning Term Hysteresis A deviation amount between the ON position and OFF position caused by auto switch characteristics (difference in sensitivity between ON and OFF).

M3 3B = M3E/M3E max = 1.8/10 = 0.18 L2 M3E m x g FE From above, n = 1 + 2a + 2b + 3A + 3B = 0.25 + 0.105 + 0.084 + 0.225 + 0.18 = 0.844 From n = 0.844 1, it is applicable. 8-16-10 10 MX MTS MY CY MG CX D-X 20Data 8-16-11 11 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F 10, 15, 25 How to Order CY1F R 10 300 F9BW Number of auto switches Magnetically coupled rodless

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX D-X 20Data 8-16-11 11 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F 10, 15, 25 How to Order CY1F R 10 300 F9BW Number of auto switches Magnetically coupled rodless cyinder, low profile guide type Nil S n 2 pcs. 1 pc. n pcs